http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
박현희(Hyun-Hee Park),오윤희(Youn-Hee Oh),이희관(Hee-Kwan Lee),우완기(Wan-Gi Woo),손종렬(Jong-Ryeul Sohn) 한국환경관리학회 2010 環境管理學會誌 Vol.16 No.2
This study was conducted to examine the characteristics of indoor air quality(IAQ) in public facilities from July 2010 to November 2010 in Incheon city. The measured indoor air pollutants are PM₁?, CO, CO₂, formaldehyde(HCHO) and TBC, the regular standard polltants of IAQ management law established by ministry of environment in Korea. As the result, the concentration of indoor air pollutants such as CO, HCHO and TBC was less than the regular standards. However, Concentration of PM₁? in child care facility and CO₂ in silver town and libraries were higher than regular standards. The public facilities of this study were not exceed each regular standards except PM₁? and CO₂. But, the child care facilities and silver town is classified as sensitive facilities that was investigated higher levels of indoor air pollution. Accordingly, it will be necessary to manage the PM₁? and CO₂ according to target facilities such as the child care facilities and silver town.
연구논문 : 주변건물군의 변화가 건물 자연환기력에 미치는 영향에 관한 연구
김미정 ( Mi Jeong Kim ),이희관 ( Hee Kwan Lee ) 한국환경영향평가학회 2011 환경영향평가 Vol.20 No.2
도시의 일상생활에서는 시가지의 바람이 나무, 집 등 낮은 건축물 군에 의해 방해되어 보통은 전원의 바람보다 풍속이 저감되는 경우가 많다. 이러한 기존의 바람 흐름이 있는 곳에 건축물이 세워지게 되면 기존의 풍환경은 크게 변화되어 풍속이 약한 곳과 강한 곳이 조성되어 이와 같은 바람이 지표부근의 구조물에 의해 받는 영향은 도시지역에서 강하게 나타나게 된다. 이는 교외나 시골지역은 상대적으로 도시지역에 비해 영향을 적게 받게 된다. 임의의 지역, 특히 도시지역의 경우 기존의 건물이 증축되거나 혹은 새로운 건물이 신축되면 이로 인하여 기존의 바람흐름이 달라지며 이는 인접건물들의 확보하고 있던 자연 환기력의 변화를 야기 시키는 원인이 되기도 한다. 이러한 현상은 건축물에 의해 자연 환기력이 바뀌게 되는 일종의 기존 환경으로 부터의 변화를 의미한다. 본 연구에서는 수치해석을 이용하여 이와 같이 건물의 주변 환경변화, 즉 신축, 증축 등과 같은 변화를 고려하여 그 영향을 예측/분석하였다. 그 결과로 건물의 자연환기력을 전면에서 바람에 의한 압력증가와 후면에서 바람의 흡입에 의한 압력감소로 인해 전면의 풍속에 의해 발생하는 동압보다 큰 압력차가 발생하고, 그로 인해 환기량이 발생하는 것을 알수 있다. 주변 변화에 의해서는 동일한 규모의 건물이 추가되는 경우에 기존의 경우에 비해 35~45%의 자연환기격이 감소되는 것으로 나타났다.
두경부종양에서 방사선조사량에 따른 FDG-PET의 변화양상
이상욱(Sang-wook Lee),김재승(Jae-Seung Kim),임기천(Ki Chun Im),류진숙(Jin Sook Ryu),이희관(Hee Kwan Lee),김종훈(Jong Hoon Kim),안승도(Seung Do Ahn),신성수(Seong Soo Shin),윤상민( Sang Min Yoon),송시열(Siyeol Song),박진홍(Jin-hong Pa 대한방사선종양학회 2004 Radiation Oncology Journal Vol.22 No.2
목 적: 두경부종양에서 근치적 목적의 방사선치료를 시행하는 경우 종양의 방사선 반응도를 예측하는 것은 방사선치료 계획을 세우는 데 있어서 매우 중요하다. 따라서 본 저자들은 방사선치료 46 Gy 시점과 종료 시점에서 FDG-PET을 시행하여 방사선치료 반응성을 예측할 수 있는지 알아보고자 하였다. 대상 및 방법: 2002년 10월부터 2003년 5월까지 서울아산병원 방사선종양학과에서 두경부종양으로 진단 받고 근치적 목적의 방사선치료를 시행 받은 22명에 대한 전향적 분석을 시행하였다. 본 연구계획서는 본원 임상윤리위원회를 통과하였고, 자발적으로 참여한 환자들에서 서면으로 동의를 받고 연구대상에 포함하였다. 모든 환자는 1차 FDG-PET을 방사선치료 시작 4주 이내에 시행하고 방사선치료 46 Gy 시점에서 제 2차 FDG-PET을 촬영하였고, 처음 계획된 선량이 모두 조사되는 시점에서 제 3차 FDG-PET을 시행하였다. 모든 환자는 최소한 방사선치료 종료 후 3개월 이상 추적하여 방사선치료 반응을 평가하였다. 결 과: 연구대상에 포함된 환자 중에서 남자는 19명이었고 여자는 3명이었다. 이들의 연령은 25세에서 70세까지 분포하였고, 중앙연령은 56세였다. 종양의 발생 부위에 따라 나누어 보면 비인강암이 13명이었고, 후두암이 6명이었고, 설암, 하인두암, 접형동암이 각각 1예였다. 방사선치료 46 Gy 시점에서 FDG- PET의 섭취가 변화 없는 경우는 1예였고 방사선치료 종료 시점에서 FDG-PET상 완전반응을 보인 경우는 20예였고 1예는 부분반응을 보였다. FDG-PET상 완전반응을 보인 20예 중에서 2예는 국소재발하였고 1예는 국소재발과 경부림프절에 동시에 재발하여 현재까지 3명이 재발하였다. 결 론: 방사선치료 46 Gy 시점에서 FDG-PET의 FDG섭취 감소가 현저한 경우는 방사선에 반응을 보이는 것으로 생각되었고 FDG 섭취의 변화가 전혀 없거나 방사선치료 종료 시점에서 FDG-PET 촬영상 완전반응을 보이지 않는 경우 잔존종양의 가능성이 매우 높다고 생각되었다. Purpose: To evaluate whether positron emission tomography (PET) with 2-[F-18]fluoro-2-deoxy-D-glucose (FDG) can be used to predict of early response to definitive aim radiotherapy (RT) in squamous cell carcinoma of the head and neck using response rate and locoregional control as study endpoints. Materials and Methods: Twenty-two patients with head and neck cancer underwent a FDG-PET study before RT, after a first dose of 46 Gy, and after a second dose of more than 70 Gy. Standard uptake value (SUV) was calculated for primary tumor (n=22) and neck lymph node (n=10). Attenuation corrected PET scans acquired 60 min after tracer injection were used for evaluation of FDG uptake in tumors. A quantitative FDG uptake index was expressed as SUVlean (corrected for lean body mass). The follow-up time was at least 5 months (range 5-15 months). Results: A total of 22 primary tumors and 10 metastatic lymph nodes were analyzed in FDG-PET. In the first PET study the mean SUV in the primary tumors and nodes were 6.4 (SD, 2.6) and 4.6 (SD, 2.3), respectively. In the second PET, study performed after 46 Gy RT the mean SUV in primary tumor and node decreased to 2.9 (SD, 1.9, p<0.001) and 1.7 (SD, 1.3) respectively. In the third PET study performed at the full dose (more than 70 Gy), RT the mean SUV in the primary tumors and nodes decreased to 2.3 (SD, 1.5, p<0.001) and 1.5 (SD, 1.1) respectively. Conclusion: FDG uptake in tumors showed a significant decrease after the 46 Gy and more than 70 Gy of RT for squamous cell carcinoma of the head and neck. Reduction of metabolic activity after 46 Gy of radiotherapy is closely correlated with radiation response.
정지원(Ji Won Jeong),이희관(Hee Kwan Lee) 大韓環境工學會 2010 대한환경공학회지 Vol.32 No.4
The common life with modern urban residence, spending more than 80~90% of daily life in indoor environment, makes the importance of indoor air quality (IAQ) even higher. Many efforts have made to improve indoor air quality (IAQ), which requires those systematic approaches for field practice. A recent study reported that no general approach cannot be made for IAQ improvement due to the great deal of variety in different indoor environments. Those indoor spaces included in Korean IAQ regulation were classified based on their characteristics and the IAQ guideline was suggested for each group of indoor spaces. Apart from those indoor spaces, the classroom in elementary school has different characteristics. By introducing the systematic approaches, the elementary classroom was surveyed and analyzed to understand its characteristics in due IAQ consideration. Based on the characteristics, there are several IAQ control measures suggested, including ventilation operation, dust mat installation, and white board. CO₂ and airborne dust were monitored and analyzed in order to evaluate the effectiveness of each control measure to IAQ. It was found that the general level of CO₂ concentration was managed under the IAQ guideline by applying the ventilator operation. The ventilation was also effective to the fugitive airborne particulate in elementary classroom environment.