http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
이종원,이미경,이형옥,이성계,도재호,김만욱 ( Jong Won Lee,Mi Kyung Lee,Hyung Ok Lee,Seong Kye Lee,Jae Ho Do Man Wook Kim ) 한국응용생명화학회 1997 Applied Biological Chemistry (Appl Biol Chem) Vol.40 No.5
The purpose of this study was to investigate the differences in proximate composition, free sugars, amino acids, fatty acids and Hunter color values between fresh and odorless garlic. The contents of crude fiber, crude fat and ash in odorless garlic were similar to those in fresh garlic. Sugars and crude protein decreased during manufacture of odorless garlic. Among the free sugars, sucrose, maltose and fructose decreased in odorless garlic, while the content of glucose increased. Total amino acid content decreased by about 30% in odorless garlic. Among the amino acids decreased arginine, isoleucine etc. The contents of linoleic acid, palmitic acid and oleic acid were higher than those of other fatty acids in fresh garlic and odorless garlic, but laruric acid was in little quantity. There were no significant differences in the Hunter L and b value between the fresh and odorless garlic, but value for greeness(-a) was lower in odorless garlic.
디지털 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 변연 및 내면 적합도 평가
이종원,박지만,Lee, Jong-Won,Park, Ji-Man 대한치과보철학회 2016 대한치과보철학회지 Vol.54 No.3
목적: 본 연구의 목적은 실제 환자에서 디지털 구강스캐너로 모형 없이 제작한 보철물의 변연 및 내면 적합도를 평가하는 것이다. 대상 및 방법: 전향적 임상시험으로 시행한 본 예비 연구는 총 11개의 수복물을 대상으로 하였다. 구강스캐너(TRIOS, 3shape, Copenhagen, Denmark)로 디지털 구강인상을 채득한 후, 캐드 디자인 및 밀링 가공 과정을 통해 전부지르코니아 수복물을 제작하였다. 완성된 지르코니아관을 환자 구강 내에 시적하였고, 레플리카 술식으로 보철물-지대치 복제물을 얻었다. 이를 근원심, 협설 방향으로 잘라 변연오차, 변연간극과 축벽부, 선각부, 교합면부의 내면간극을 측정하였다. 통계처리는 Kruskal-Wallis 검정과 Mann-Whitney U 검정을 이용하여 통계적 유의성을 분석하였다(${\alpha}=.05$). 결과: 복제물을 통한 적합도 분석 결과, 근원심, 협설 절편 사이에는 통계적으로 유의한 차이가 없었다(P>.05). 변연간극에 불일치가 있었으며, 변연 오차가 변연간극 보다 컸다(P<.01). 결론: 본 연구의 한계 내에서, 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 적합도는 임상적으로 허용할만한 결과를 보였다. 그러나 지르코니아관의 변연부위가 과풍융되는 경향이 있었으므로 주의 깊은 임상 적용 및 추적 연구가 요구된다. Purpose: The aim of this study was to evaluate the marginal and internal adaptation of monolithic zirconia restoration made without physical model by digital intraoral scanner. Materials and methods: A prospective clinical trial was performed on 11 restorations as a pilot study. The monolithic zirconia restorations were fabricated after digital intraoral impression taking by intraoral scanner (TRIOS, 3shape, Copenhagen, Denmark), computer-aided designing, and milling manufacturing process. Completed zirconia crowns were tried in the patients' mouth and a replica technique was used to acquire the crown-abutment replica. The absolute marginal discrepancy, marginal gap, and internal gap of axial, line angle, and occlusal part were measured after sectioning the replica in the mesiodistal and buccolingual direction. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U test (${\alpha}=.05$). Results: From the adaptation analysis by replica, the statistically significant difference was not found between mesiodistal and buccolingual sections (P>.05), but there was significant difference among the measurement location (P<.01). The amount of absolute marginal discrepancy was larger than those of marginal gap and internal gap (P<.01). Conclusion: Within the limitations of this study, the adaptation accuracy of model-free monolithic zirconia restoration fabricated by intraoral scanner exhibited clinically acceptable result. However, the margin of zirconia crown showed tendency of overcontour and cautious clinical application and follow up is necessary.
운동방정식을 기저로 한 스튜워트 플랫폼 운동장치의 제어시스템 설계 및 슬라이딩 모드제어
이종원,김낙인,Lee, Chong-Won,Kim, Nag-In 대한기계학회 1999 大韓機械學會論文集A Vol.23 No.6
A high speed tracking control system for 6-6 Stewart platform manipulator is designed for performing the model based joint-axis sliding mode control. Because of the complex dynamics and kinematics of the Stewart platform manipulator, two computer systems, consisting of a PC and a DSP, are adopted, so that real time tasks are run in synchronous and asynchronous modes. It is experimentally proven that the proposed control system makes the convenience in implementation of model based tracking control, so that it can achieve effective tracking control under relatively high speed and additional payload conditions.
이종원,오세훈,김준철,전한수,Lee, Chong-Won,Oh, Se-Hoon,Kim, Jun-Cheol,Jeon, Han-Su 대한기계학회 1997 大韓機械學會論文集A Vol.21 No.7
Due to progress in manufacturing techniques, the performance of the harmonic drive has been improved but not sufficiently. One of the important problems which the current harmonic drive has is that while there is the potential for having a wider tooth contact area, the total number of teeth engaged simultaneously is still small. This is mainly due to the involute tooth profile. Hence, in this study, the cycloid-type tooth profile is developed to improve this problem. This paper represents the design methodology and performance evaluation f the cycloid-type harmonic drive. Cycloide tooth profile was derived by analyzing geometry of the tooth engagement and the contact mechanisms of the tooth which were examined and analyzed by load analysis. The stress due to elastic deformation of a flexspline was also obtained by approximate formula and computer analysis. Finally, the cycloid-type harmonic drive with 1:100 speed ratio was manufactured and the performance of the harmonic drive was evaluated.
교통동맥분절의 내측벽에서 기원한 내경동맥류 치험 2례 - 증례보고 -
이종원,석종식,권정택,민병국,Lee, Jong-Won,Suk, Jong-Sik,Kwon, Jung-Taek,Min, Byung-Kook 대한신경외과학회 2000 Journal of Korean neurosurgical society Vol.29 No.10
Aneurysms of the medial wall of the internal carotid artery(ICA) constitute a rare group of ICA aneurysms arising at locations other than at arterial division. Because these aneurysms usually have thin walls and wide necks associated with arteriosclerosis, neck clipping should be taken into special consideration. The authors report two cases of the aneurysm presented with subarachnoid hemorrhage, in which neck clippings ware performed with impunity.