중온수 흡수식 냉동기용 유하 액막식 재생기의 전열관 성능 특성에 관한 연구
이준하(Joon-Ha Lee),김병련(Beyung-Leyean Kim),이광표(Gwang-Pyo Lee),박찬우(Chan-Woo Park) 대한기계학회 2013 대한기계학회 춘추학술대회 Vol.2013 No.12
The objective of this study is to investigate the changes of the performance of a hot water absorption chiller as influenced by the characteristics of the heating tubes inserted in its generator. The absorbent and the refrigerant flowing inside the generator are LiBr and water, respectively. The experiments were done based on a 58% absorbent concentration. In the experiments, the inlet and outlet temperatures of the absorbent and the inlet and outlet temperature of the refrigerant in the generator are measured. Also, the pressure of the generator and the flow rate of the refrigerant and the absorbent we measured. A Labview program was used for the measurements. Tests were conducted on different types of heating tubes using the same experimental conditions and the values of the overall heat transfer coefficient are determined. With this, the type of heating tubes that results to the improvement of the performance of the absorption chiller can be identified.
제 2종 흡수식 히트펌프의 냉매열교환기 적용에 따른 특성 변화에 관한 연구
이창현(Chang Hyun Lee),윤준성(Jun Seong Yoon),이광표(Gwang Pyo Lee),서양(Yang Seo),김인관(In Gwan Kim),권오경(Oh Kyung Kwon),차동안(Dong An Cha),배경진(Kyung Jin Bae),김민수(Min Su Kim),박찬우(Chan Woo Park) 대한설비공학회 2017 대한설비공학회 학술발표대회논문집 Vol.2017 No.6
This study was carried out a numerical analysis the effects of how to configure refrigerant heat exchanger on the performance of type II absorption heat pump. There are two kinds of heat exchange methods, solution to refrigerant and waste hot water to refrigerant. When the waste hot water is bypassed to the refrigerant heat exchanger, steam mass rates ars increased compared to the standard model. When the solution was bypassed to the refrigerant heat exchanger, steam mass rates are lower than in the case where the waste heat water was used in the refrigerant heat exchanger. Thus, in constructing the refrigerant heat exchanger, it is possible to obtain a higher Steam mass value by using waste water than by using a solution.
MWCNT의 가공에 따른 MWCNT/열경화성수지 복합소재의 열전도도 특성에 관한 연구
강석민(Seok-Min Kang),이광표(Gwang-Pyo Lee),박찬우(Chan-Woo Park) 대한설비공학회 2013 대한설비공학회 학술발표대회논문집 Vol.2013 No.6
In this study, the thermal conductivity properties of MWCNT/epoxy matrix composites were investigated. The composites were fabricated by mixing multiwalled carbon nanotubes (MWCNT) and thermosetting resin matrix. As generally known, MWCNT have high thermal conductivity. In order to determine the influence of MWCNT concentration on the thermal conductivity of the material, the weight ratio of the MWCNT was varied (2.5 wt.%, 5 wt.%, 10 wt.%, and 15 wt.%). Also, the MWCNT were processed by ball milling at various milling times (15 min, 30 min, 45 min, and 60 min) to increase its bulk surface area. Furthermore, the compatibility of MWCNT with other filler materials was considered.