22.9㎸ 폐쇄 배전반내의 사고모델을 통한 실험적 검증
宋佶穆(Kil-Mok Shong),韓雲基(Woon-Ki Han),崔忠錫(Chung-Seog Choi) 대한전기학회 2006 전기학회논문지 P Vol.55 No.2
This paper describes the accident analysis by modelling the current transformer mounting in a metal-clad switchgear at 22.9㎸. In analyzing the accident, the reconstruction at the current transformer mounting(VCB connecting guide) has to be taken into account. The accident was modelled as a 3-phase ground fault occurring between the end plate of 22.9㎸ lines and the safety shutter at the current transformer mounting of the VCB inside the metal clad switchgear. Since the outside maintenance of the metal clad switchgear is restricted by the enclosed compartments, its circumference has to be kept clean. Through the reconstruction results, it was confirmed that the fault of the enclosed switchboard could be reduced when the shutter made of Fe material was changed into an insulation.
송길목(Kil-Mok Shong),방선배(Sun-Bae Bang),김종민(Jong-Min Kim),김영석(Young-Seok Kim),최명일(Myoung-Il Choi),신진용(Jin-Yong Shin) 대한전기학회 2010 대한전기학회 학술대회 논문집 Vol.2010 No.7
저압용 누전차단기는 부하사용 중 인체감전을 방지하기 위한 보호장치로서 외부환경에 노출되었을 때 하우징은 상대적으로 열화가 빨리 진행되는 경향이 있다. 특히 색차지수에 의해 변색정도와 반사율에 따른 변화를 평가하여 주변환경에 대한 평가와 차단기의 특성을 확인하는데 매우 효과적이다. 본 연구에서는 색차지수에 따른 누전차단기의 하우징 재질특성을 분석하여 주변 환경평가와 차단기 각 사의 하우징 특성을 비교하였다. 광촉진 열화와 외부 폭로시험을 통해 단계별로 샘플링하여 분석한 결과를 토대로 누전차단기 성능개선을 위한 자료로 활용이 가능하리라 기대된다.
브래킷 유리애자의 접합재로 이용되는 알루미나 시멘트의 특성
송길목(Kil-Mok Shong),정진수(Jin-Soo Jung),한운기(Woon-Ki Han),김영석(Young-Seok Kim),류영태(Young-Tae Ryu),전용주(Yong-Joo Jun) 대한전기학회 2008 대한전기학회 학술대회 논문집 Vol.2008 No.9
Damaged glass insulator that is utilized the high-speed railroad in domestic try to find the cause. This paper is investigated on the characteristics of alumina cement as the binder of glass insulator. The components of glass insulator are stub(tin), rod(tin), shed(tempered glass), and alumina cement. If composition of alumina cement is not unified, crack of alumina cement generated. As these results, cracked marks of cement is appeared and composition of alumina cement is not unified. Therefore, it is estimated that main element of long-term degradation is a alumina cement.
폴리머 애자의 내전압 특성에 따른 부분방전 측정과 자외선 검출
송길목(Kil-Mok Shong),김영석(Young-Seok Kim),김종서(Jong-Seo Kim),정진수(Jin-Soo Jung) 대한전기학회 2008 대한전기학회 학술대회 논문집 Vol.2008 No.9
The purposes of this paper ensure for the economical efficiency, accuracy, and good applications in domestic site set up the power installations. For the efficient conduct of these purposes, there are measured the partial discharge(PD) used by current probe and compared with detected signal of UV sensor. As the results, PD generated about 35% of breakdown voltage in polymer insulator. UV signal due to high voltage in polymer insulator is detected from about 1.7㎷ at 30㎸ to about 3㎷ at 70㎸. Signal detected by ultra-sonic is increased at about 75% of breakdown voltage abruptly. It appears that error range is increased in boundary. UV sensor is needed must use from the practical and economical points of view.
송길목(Shong, Kil-Mok),정호성(Jung, Ho-Sung),권창오(Kwon, Chang-Oh) 대한전기학회 2022 전기의 세계 Vol.71 No.11
전기설비 측면의 탄소중립 감축을 위하여 Energy shift 와 Modal shift 와 같은 전략적인 추진방법이 필요하다. 전기설비 생애주기의 전 과정에 있어서, 전기안전 분야에서의 유지 · 관리를 통한 전기설비 효율 증가, 전기재해 예방, 주요전력설비 배출계수 관리 방안 / 전기철도 기반 전기수송 분야에서의 Modal shift를 통한 친환경 수송자원으로의 변환 방안 / 설비시공 분야에서의 전환과정 진행상황 관리를 통한 목표달성 상태 확인 방안을 추진전략으로 제시하였다.