표면 온도 저하율에 따른 창호부 결로성능 예측에 관한 연구
성욱주(Uk-Joo Sung),조수(Soo Cho),장철용(Cheul-Yong Jang),이진성,백상훈(Sang-Hun Peak) 대한설비공학회 2006 대한설비공학회 학술발표대회논문집 Vol.2006 No.4
This present study analyzed temperature depreciation ratio of window inside surface by KS F 2295 "Procedure for determining fenestration product condensation resistance values". it estimated window indoor surface condensation due to variable environmental condition. Performance of condensation resistance by using temperature depreciation ratio until applied Low-e and Ar glazing improved about 45% from 24 ㎜ clear. Temperature depreciation ratio by KS F 2295 considers analytic index of window condensation due to variable boundary condition.
실내 수증기 발생에 따른 주거형 창호의 지속적 결로에 관한 연구
성욱주(Sung Uk-Joo),조수(Cho Soo),장철용(Jang Cheol-yong),이진성(Lee Jin-Sung),백상훈(Paek Sang-Hun),박상우(Park Sang-Woo),송규동(Song Kyoo-Dong) 한국태양에너지학회 2006 한국태양에너지학회 학술대회논문집 Vol.- No.-
The purpose of this study is to investigate continuance of window condensation followed by diffusion and retardation by the factors of indoor vapor occurring. It's necessary to extend the application limit of indoor condition of performance test on the prediction and the level about a condensation occurring on the window to analyze influence of vapor in the air in the room over condensation occurring on the window. It measured the infiltration of the selected house by pressurization test. The result of the test is applied to input parameter of TRNFLOW simulation program of multi zone air flow. On the other hand, It gets the surface temperature decrease of the selected window by Therm 5, heat transfer analysis program of window element. Surface temperature decrease is used to estimate condensation of window surface. Finally, it investigates continuance of window condensation followed by diffusion and retardation by the factors of indoor vapor occurring. In the result of the research on diffusion and retardation of vapor, condensation occurs more in a zone with less infiltration than in other zones. Condensation can often occur in Non-heating spaces.
표면 온도 저하율에 따른 창호부 결로성능 예측에 관한 연구
성욱주(Uk-Joo Sung),조수(Soo Cho),장철용(Cheul-Yong Jang),이진성,백상훈(Sang-Hun Peak) 대한설비공학회 2006 대한설비공학회 학술발표대회논문집 Vol.2006 No.6
This present study analyzed temperature depreciation ratio of window inside surface by KS F 2295 ‘Procedure for determining fenestration product condensation resistance values’. it estimated window indoor surface condensation due to variable environmental condition. Performance of condensation resistance by using temperature depreciation ratio until applied Low-e and Ar glazing improved about 45% from 24 ㎜ clear. Temperature depreciation ratio by KS F 2295 considers analytic index of window condensation due to variable boundary condition.
창호통합형 배열회수 환기시스템의 열성능 및 경제성 평가
성욱주(Uk-Joo Sung),조수(Soo Cho),송규동(Kyoo-Dong Song) 대한설비공학회 2012 설비공학 논문집 Vol.24 No.8
This study is intended to analyze the thermal performance and evaluate the applicability about non-duct type heat recovery ventilation system integrated with window. Eventually, economic analysis of the system is conducted according to building energy saving ratio of it. As results of the thermal performance, the U-factor of the window conducted on the basis of KS F 2278 appears to 1.8 W/㎡K, and the effective heat exchange efficiency of the ventilator conducted on the basis of KS B 6879 appears 49.95% for cooling, 66.89% for heating. In the applicability evaluated by TRNSYS 16, the caes of applying the heat recovery ventilator integrated with window is found to reduce the cooling or heating load by 2.9% or 13.5% than the non-ventilator case. The results of economic analysis taking a side of consumer is verified as the payback is 3 years, and the accumulated earning is 1,408,133 won in terms of ‘600,000 won/unit’ for initial cost, 10 years for useful life of the system.
성욱주(Uk-Joo Sung),이진성(Jin-Sung Lee),조수(Soo Cho),장철용(Cheol-Yong Jang),백상훈(Sang-Hun Paek),송규동(Kyoo-dong Song) 대한설비공학회 2006 대한설비공학회 학술발표대회논문집 Vol.2006 No.6
Purpose of this study is proposal of estimating method about window thermal performance that based on KS F 2278 'Test method of thermal resistance for windows and doors' due to material composition of PVC frame window. First step of this study is research of present state about material composition of PVC frame window. Second is selection of main effective elements about window thermal resistance. For example, composition of Glazing, Frame area ratio of total window area, frame width, opening type, area of heat transfer and so on. Third is multiple regression analysis about thermal performance of PVC frame window due to main effective elements. It produces equations of multiple regression analysis due to opening type. Case of sliding window is Y = 0.149 + 0 .034X<SUB>g</SUB> + 0.248X<SUB>far</SUB>, 4track sliding is Y = 0.584 + 0.175X<SUB>g</SUB> + 1.355X<SUB>far</SUB> -0.008X<SUB>fw</SUB>, Tilt & Turn window is Y = -0.161 + 0.076X<SUB>g</SUB> + 0.576X<SUB>far</SUB> + 0.0008X<SUB>fw</SUB>.
백상훈(sang-hun Peak),이진성(Jin-Sung Lee),조수(soo Cho),장철용(Cheol-Yong Jang),성욱주(Uk-Joo Sung),서승직(Seung-Jik Suh) 대한설비공학회 2006 대한설비공학회 학술발표대회논문집 Vol.2006 No.6
Heat loss by window in building occupies about 1/4 of energy amount used building. Therefore, high thermal insulation of windows system can speak as very important part in save energy of building. in this research, After select most suitable frame design and Glazing system for high thermal insulation of windows, execute simulation of mixing frame and Glazing System. Also, manufacture windows with the result and execute verification experiment, with verified simulation, this research evaluated thermal insulation performance of window by Glazing System's change.
건축물 외피의 옥외 시험실 규모 공간단위 냉·난방에너지 성능평가를 위한 교정열량 산출 방법론
신상용(Shin, Sang-Yong),최민호(Choi, Min-Ho),안병립(Ahn, Byung-Lip),성욱주(Sung, Uk-Joo) 한국건축친환경설비학회 2019 한국건축친환경설비학회 논문집 Vol.13 No.3
Based on policy for the energy saving of the building sector, the energy performance index for the building envelope and the results according to the standardized test method are evaluated based on performance criteria. The energy-related performance evaluation method of the building envelope utilizes the performance index such as the thermal conductivity. Considering the time and the cost, the influence factors to evaluate energy performance are extremely limited. Therefore, we propose a calorie calculation methodology to evaluate the heating and cooling energy performance of a building envelope using an outdoor laboratory that can simulate buildings exposed to actual environmental conditions (radiation, temperature, humidity, wind speed, etc.). Energy performance evaluation of the exterior of the building using the outdoor space unit. This paper presents energy performance evaluation method of building envelope using outdoor space unit test room and evaluation of heating energy performance of glass specimen. The energy performance of the building envelope can be compared by calculating the input heat quantity according to the temperature difference range of the inside and outside of the test room.
백상훈(Paek sang-hun),조수(Cho soo),장철용(Jang Cheol-Yong),이진성(Lee Jin-Sung),성욱주(Sung Uk-Joo),박상우(Park Sang-Woo),서승직(Suh Seung-Jik) 한국태양에너지학회 2006 한국태양에너지학회 학술대회논문집 Vol.- No.-
Research about most suitable design of superhigh adiabatic super windowsHeat losses by windows and doors, acquisitions are dominating large percentage whole building loads. development of high adiabatic windows and doors system is one of important part on save energy dimension. Be ing comparing to result existent windows and doors system that analyze this research and show overall heat transmission rate decreases more than about 50%. Producing sample ore hereafter with result of this research an actual proof experiment by measuring the mortification overall heat transmission rates. If continuous research is achieved in skill application side commercialization, large quantity production, Low-Cost it is expected to contribute greatly in saveenergy of building.
실내 루버형 집광채광시스템의 조명에너지 절감에 대한 연구
신상용(Shin, Sang-Yong),성욱주(Sung, Uk-Joo) 한국건축친환경설비학회 2020 한국건축친환경설비학회 논문집 Vol.14 No.4
The indoor louver type concentrating daylighting system, which is one of the renewable energy systems, can reduce the consumption of lighting energy. But it has few research cases evaluating the lighting energy saving performance. In this study, the LED dimming control system was applied to analyze the indoor environment and lighting energy saving effect for 3 days during the fall. The visual environment performance was compared with KS average indoor illumination range of office and uniformity of BREEAM. The lighting energy saving rate was calculated to be 67% to 87% per hour and 52% to 61% per day, and it varies depending on the external illuminance and time. Afterwards, it will be possible to quantify changes due to changes in outdoor illuminance when increasing statistical data, as well as research on lighting energy saving performance according to the angle of slat and whether automatic control is applied.