니코틴 중독의 단서노출치료를 위한 가상환경의 제작 및 욕구 유발 시험
김광욱 ( Kwang Uk Kim ),조원근 ( Won Geun Cho ),구정훈 ( Jeon Hun Ku ),김훈 ( Hun Kim ),김병년 ( Byoung Nyun Kim ),이장한 ( Jang Han Lee ),김인영 ( In Y. Kim ),이종민 ( Jong Min Lee ),김선일 ( Sun I. Kim ) 한국감성과학회 2002 추계학술대회 Vol.2002 No.-
Research has shown that many smokers experience an increase in the desire to smoke when exposed to smoking-related cues. Cue exposure treatment (CET) refers to the manualized, repeated exposure to smoking-related cues, aimed at the reducing cue reactivity by extinction. In this study, we constructed a virtual reality system for evoking a desire of nicotine, which was based on the results of a Questionnaire of Nicotine-craving. And we investigated the effectiveness of the virtual reality system as compared to classical device (pictures). As a result, we reached the conclusion that virtual reality elicits more craving symptoms than the classical devices.
박은경,이상민,한영호,이종연,권세윤,김인영,김선일,Park E. K.,Lee S. M.,Han Y. H.,Lee J. Y.,Kwon S. Y.,Kim I. Y.,Kim Sun I. 대한의용생체공학회 2004 의공학회지 Vol.25 No.6
혈압은 심혈관계 질환을 비침습적인 방법으로 진단할 때 사용하는 중요한 생리적 지표 중 하나이다. 보통 동맥 혈압을 측정하기 위해 사용되는 기존의 비침습적인 방법들은 커프를 사용해야 하며. 연속적 혈압 측정이 어렵다. 수축기 혈압과 맥파전달시간은 서로 반비례 관계를 가지고 있다. 실험은 피검자로부터 휴식을 통한 평온한 상태와 운동을 통한 격한 상태로부터 수축기 혈압과 맥파전달시간 데이터를 얻었다. 얻어진 데이터를 이용하여 각 피검자용 회귀식과 전체 피검자용 회귀식을 만들기 위해 선형회귀분석을 하였다. 만들어진 회귀식의 정확도를 검증하기 위해 측정한 수축기 혈압값과 예측한 수축기 혈압값을 비교하였다. 비교 결과, 각 피검자용 회귀식이 혈압계는 오차의 평균과 표준편차가 각각 ±5mmHg, 8 mmHg를 가져야 된다고 규정한 American National Standards Institute of the Association of the Advancement of Medical Instrument (ANSI/AAMI)에 적합하였다. 그러나 전체 피검자용 회귀식은 ANSI/AAMI의 규정에 적합하지 않았다. 이 결과는 맥파전달시간과 각 피검자에 맞는 초기 보정을 통해서 커프를 사용하지 않고, 연속적으로 수축기 혈압을 측정할 수 있음을 의미한다. Blood pressure (BP) is one of the important physiological parameters for diagnosing cardiovascula diseases by means of noninvasive method. Existing noninvasive methods for measuring arterial BP have to use cuff and difficult in measuring arterial BP continuously. Systolic blood pressure (SBP) and pulse transit time (PTT) have a kind of inverse relationship. We acquired PTT data when subjects were in relaxation and also after exercise. We performed the linear regression analysis for making the regression equations for each subject and the regression equation for all subjects. We compared the estimated SBP with the measured SBP to check the accuracy of our regression equations. From the result, the regression equations for each subject was appropriate according to the American National Standards Institute of the Association of the Advancement of Medical Instrument (ANSI/AAMI) which says that BP devices should have ±5mmHg mean of error and 8mmHg standard deviation of error. However, the regression equation for all subjects was not proper to ANSI/AAMI recommendation. The result means that, without cuff, we can continuously estimate each subject's SBP through PTT and indivisual calibration.
이기혁(K. H. Lee),강신일(S. I. Kang),조재성(J. S. Cho),임도형(D. H. Lim),이종실(J. S. Lee),김인영(I. Y. Kim) 한국재활복지공학회 2015 재활복지공학회논문지 Vol.9 No.2
본 논문은 자체 개발한 관성측정장치의 가속도, 각속도, 지자기계 데이터를 이용하여 보행거리를 측정하는 시스템 개발에 관한 것이다. 관성센서들의 오프셋 및 이득 오차를 최소화하기 위하여 9축의 자유도를 갖는 지그를 제작하였으며, 이를 이용하여 캘리브레이션을 수행하였다. 보행거리의 정확한 측정을 위하여, 기울기 하강법을 이용하여 가속도계의 중력성분 제거 및 보행패턴 분석을 통한 드리프트 성분을 제거하였다. 최종적으로 보정된 가속도 데이터의 이중적분을 통하여 보행거리를 측정하였다. 시스템의 성능 평가를 위하여, 실내 직선 10m 직선 보행에 대하여 캘리브레이션 전, 후 오차 개선 비율를 비교하였으며, 간단한 보행에 대해 Vicon과의 비교 실험을 수행하였다. 직선 보행에 대해서는 x, y, z축 각각에 대하여 31.4±14.38%(mean±S.D.), 78.64±10.84% 및 69.71±26.25% 개선이 되었음을 확인하였으며, Vicon과의 비교 실험 결과 x, y, z축 각각에 대하여 0.1m, 0.16m, 0.12m의 오차를 얻을 수 있었다. In this paper, we present an inertial sensor-based gait distance measurement system using accelerometer, gyroscope, and magnetometer. To minimize offset and gain error of inertial sensors, we performed the calibration using the self-made calibration jig with 9 degrees of freedom. For measuring accurate gait distance, we used gradient descent algorithm to remove gravity error and used analysis of gait pattern to remove drift error. Finally, we measured a gait distance by double-integration of the error-removed acceleration data. To evaluate the performance of our system, we walked 10m in a straight line indoors to observe the improvement of removing error which compared un-calibrated to calibrated data. Also, the gait distance measured by the system was compared to the measurement of the Vicon motion capture system. The evaluation resulted in the improvement of 31.40±14.38%(mean±S.D.), 78.64±10.84% and 69.71±26.25% for x, y and z axis, respectively when walked in a straight line, and a root mean square error of 0.10m, 0.16m, and 0.12m for x, y and z axis, respectively when compared to the Vicon motion capture system.
박영민(Y. M. Park),안종훈(J. H. Ahn),김인영(I. Y. Kim) 제어로봇시스템학회 2012 제어로봇시스템학회 합동학술대회 논문집 Vol.2012 No.7
폭발에 의해 발생하는 폐의 변형을 계산하고 그에 따르는 손상을 예측할 수 있는 모델을 제시한다. 비선형 연속체 역학(nonlinear continuum mechanics)에 기반하여 폐의 계층적 구조 모델을 전개하고 결과적으로 얻게 되는 세 가지 매개변수를 통해 손상을 예측할 수 있다.
강신일(S. I. Kang),조재성(J. S. Cho),임도형(D. H. Lim),이종실(J. S. Lee),김인영(I. Y. Kim) 한국재활복지공학회 2013 재활복지공학회논문지 Vol.7 No.2
본 논문은 몸 전체의 움직임을 측정하고 분석할 수 있는 관성센서 기반 모션 캡처링 시스템에 관한 것이다. 본 시스템 구현을 위해 자이로스코프, 가속도계 및 지자계 신호를 이용한 자세·방위 측정장치 모듈을 개발하였으며, 다수의 모듈을 환자의 분절에 부착하고 공간상에서 각 분절의 방위각을 계산하여 3차원 모션캡처를 수행하였다. 또한 재활과 관련된 많은 응용에 있어 중요한 생체역학 측정값인 신체 분절간의 관절각을 추출하는 알고리즘을 제안하였다. 개발한 자세·방위 측정장치 모듈의 성능을 평가하기 위하여 3차원 공간상의 변위 및 방위를 밀리미터 해상도로 제공할 수 있는 Vicon을 참조 측정 시스템으로 이용하였으며, 2.56도의 평균 제곱근 오차를 얻을 수 있었다. 실험 결과 본 연구에서 개발한 시스템은 뇌졸중 후 회복단계 동안 사지 및 보행 동작을 실시간으로 분석, 제공함으로서 재활의 효과, 난이도 조절 및 피드백 요소를 제공할 수 있을 것으로 판단된다. In this paper, we present an inertial sensor-based motion capturing system to measure and analyze whole body movements. This system implements a wireless AHRS(attitude heading reference system) we developed using a combination of rate gyroscope, accelerometer and magnetometer sensor signals. Several AHRS modules mounted on segments of the patient’s body provide the quaternions representing the patient segments’s orientation in space. We performed 3D motion capture using the quaternion data calculated. And a method is also proposed for calculating three-dimensional inter-segment joint angle which is an important bio-mechanical measure for a variety of applications related to rehabilitation. To evaluate the performance of our AHRS module, the Vicon motion capture system, which offers millimeter resolution of 3D spatial displacements and orientations, is used as a reference. The evaluation resulted in a RMSE of 2.56 degree. The results suggest that our system will provide an in-depth insight into the effectiveness, appropriate level of care, and feedback of the rehabilitation process by performing real-time limbs or gait analysis during the post-stroke recovery process.