http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
펜타캠을 이용한 섬유주 절제술 전후의 각막 고위수차와 전방계측치의 변화 관찰
김병선,김병재,정인영,서성욱,유지명,김성재,Byoung Seon Kim,MD,Byung Jae Kim,MD,In Young Chung,MD,PhD,Seong Wook Seo,MD,PhD,Ji Myong Yoo,MD,PhD,Seong Jae Kim,MD,PhD 대한안과학회 2014 대한안과학회지 Vol.55 No.5
Purpose: To evaluate changes in corneal keratometry, high-order aberrations (HOAs), and anterior chamber parameters after trabeculectomy using Pentacam<sup>® (Oculus Inc., Dutenhofen, Germany). Methods: Forty eyes of 40 patients who underwent limbal-based trabeculectomy or fornix-based trabeculectomy between July 2011 and May 2012 were retrospectively reviewed. Intraocular pressure (IOP), corneal keratometry, central corneal thickness, anterior chamber depth, anterior chamber volume, and HOAs were measured using Pentacam<sup>® preoperatively and at 3 months postoperatively. Results: The mean age of patients who underwent trabeculectomy was 58.26 ± 16.28 years. IOP showed significant decrease after surgery in both groups compared to preoperative values (<em>p</em> < 0.05). There were no significant differences in corneal keratometry, anterior chamber depth, anterior chamber volume, central corneal thickness, total root mean square (RMS), trefoil, and coma after surgery (<em>p</em> > 0.05). Conclusions: Postoperative corneal keratometry and anterior chamber parameters did not change significantly compared to preoperative values in glaucoma patients after performing trabeculectomy. Most HOAs that affected quality of vision were not changed in the limbal-based trabeculectomy or fornix-based trabeculectomy. J Korean Ophthalmol Soc 2014;55(5):662-668
기후변화협약에 대응하는 건물에너지 정책에 관한 의식조사 연구
김혜진(Kim, Hye-Jin),탁지연(Tak, Ji-Yeon),이민정(Lee, Min-Jeong),이하연(Lee, Ha-Yeon),김소담(Kim, So-Dam),최주혜(Choi, Ju-Hye),김나임(Kim, Na-Im),김은서(Kim, Eun-Seo),김병선(Kim, Byung-Seon) 대한건축학회 2017 대한건축학회 학술발표대회 논문집 Vol.37 No.2
According to Paris Agreement that will replace Kyoto Protocol, Korea set a target of 37% reduction in Business As Usual (BAU). Buildings account for about 30% of Green House Gas (GHG) emissions, and many countries are promoting the policy to supply green building. Korea induces energy efficiency improvement and energy saving of buildings through a range of policies. However, it has a difficulty in producing actual effect by problems of the process of policy formulation and lack of awareness of policy demanders. Therefore, I searched solutions to supply green building and save energy using buildings to analyse and examine ordinary citizens pertaining to government policy.
김태연(Kim. Taeyeon),김창남(Kim. Chang-Nam),홍구표(Hong. Gu-Pyo),김광호(Kim. Kwang-Ho),노지웅(Rho. Ji-Woong),김병선(Kim. Byung-Seon) 대한건축학회 2004 대한건축학회 학술발표대회 논문집 - 계획계/구조계 Vol.24 No.1
The Purpose of this study was to analyze the smoke elimination performance and evacuation time in an arcade of traditional market. In this study, the effect of the opening for the ventilation about the smoke eliminating performance was analyzed using CFD (Computational Fluid Dynamics) method. And also the evacuation time was analyzed according to the height of the building. The opening of the arcade is very important design factor to control the smoke movement.
기후변화협약에 대응하는 건물에너지 정책 현황 및 문제점 분석
김혜진(Kim, Hye-Jin),홍준(Hong, Jun),김혜원(Kim, Hye-Won),김형택(Kim, Hyung-Taek),김병선(Kim, Byung-Seon) 대한건축학회 2017 대한건축학회 학술발표대회 논문집 Vol.37 No.2
According to launching of Paris Climate Change Accord, Reduction targets of Korea in Business As Usual (BAU) scenarios are set at 37%. Building sectors, which account for about 30%, of Green House Gas emissions, have more room for reduction and lower cost than industrial sectors, so many countries are striving to conserve building energy reduction by supplying green buildings. Korea also induces energy efficiency improvement and energy savings via a diverse policy. However, it can not produce actual results for problems in the process of policy formulation and lack of knowledge of policy demanders. Therefore, government policy should be converted into direction leading to participation of an end user and architects in the process of establishment.
김광호(Kim. Kwang-Ho),홍구표(Hong. Goo-Pyo),김태연(Kim. Taeyeon),노지웅(Roh. Ji-Woong),김병선(Kim. Byung-Seon) 대한건축학회 2004 대한건축학회 학술발표대회 논문집 - 계획계/구조계 Vol.24 No.1
The purpose of this study was to classify the design types of arcade including the width of road, the buildings around the market, the height of ventilation opening, the height of arcade roof and etc, analyzing eleven traditional markets in Seoul for thermal, ventilation, and fire performance by simulation and experiment. The results of this study were as follows; the arcade design types are roughly classified into 2 groups by the shape of arcade roof, monitor and vault, including that the width of road was divided into 4 groups(6m, 8m, 12m, 12m-) by traffic lane, and there are so many buildings have two floor, and so on.
병영시설의 에너지 성능개선을 위한 부하패턴 분석 및 외피시스템 사례 기초연구
김철(Kim Chul),박찬혁(Park Chan-Hyuk),김병선(Kim Byung-Seon) 대한건축학회 2010 대한건축학회논문집 Vol.26 No.4
Recently, overseas countries trying to restoration the ecosystem and environment for make preparation to the dearth of resources and environmental disruption. Especially, propagation of renewable energy and reusing energy technologies are made progress around Europe, United States and Japan. In the case of Korea, supply rate of the renewable energy is insignificant condition that slightly 2.58%(2008) and now it’s spread out around a government agency and public enterprises. In addition, government announced "green growth" policy by means of new growth motive because necessity of energy efficiency improvement and building sustainable energy. Therefore, the purpose of this study is embody the sustainable military facility model that applied improving energy performance and load retrenchment technology in design process. In the progress, load analysis of facility and passive design are performed for check propriety of applying passive system. Procedure of this study is to simulate eQuest 3-6 that includes heating and cooling loads calculating. Also, simulating model for load analysis is based on B individual observation post, Camp OO, Republic of Korea Marine corps.
초고층 공동주택에서 발코니 확장에 따른 창호시스템별 냉방부하 분석 및 비교
김윤진(Kim Yun-Jin),박상현(Park Sang-Hyun),이종찬(Lee Jong-chan),임정희(Lim jung-Hee),김병선(Kim Byung-Seon) 한국태양에너지학회 2008 한국태양에너지학회 학술대회논문집 Vol.- No.-
These days, Apartment is altered oversized and high-rise through construction techniques development. Also, the cost of cooling and heating load would be expected by balcony expansion into inner space caused by legalization. In specially, HVAC systems of high-rise residential building almost apply to pre-existence techniques of middle and low residential building except for consideration and methods of the air inflow minimization into indoor through mechanical ventilation is used in ventilation system. From these cause, window systems of high-rise apartments stands high in estimation of components. Thus, purpose of this study is to make a comparative study through difference of window systems.