콘크리트의 압축강도 추정을 위한 비파괴시험식에 관한 연구
권영진,오상근,김무한,Kwon, Young-Jin,Oh, Sang-Kun,Kim, Moo-Han 한국구조물진단유지관리공학회 1997 한국구조물진단유지관리공학회 논문집 Vol.1 No.1
The major object of this study is to analyze and investigate experimentally the experimenal equation for the estimate of compressive strength of concrete. The results are as follows. The relation between maturity scaled logarithm and compressive strength of concrete can be expressed in liner equation which show an good correlation. And combined method using rebound number, pulse velocity and water cement ratio also show an excellent correlation. The equation by combined method is same as the conclusions.
고강도콘크리트의 내구성진단을 위한 영향인자 파악을 위한 연구
권영진,김무한,Kwon, Young-Jin,Kim, Moo-Han 한국구조물진단유지관리공학회 1997 한국구조물진단유지관리공학회 논문집 Vol.1 No.2
The effect of experimental factors on the Freeze-Thaw durability in the High Strength Concrete has been analyzed and investigated with [DESIGN of EXPERIMENT: L16). The Experimental parameters included the type of aggregate and mixer, the conditions of aggregates, and the difference of mixing temperature, procedure and placing, etc. It is aim of this study to provide the fundamental data on the effect of various factors on the frost resistance of high strength concrete for the practical use and research data accumulation of durability inspection. The results of this experiment indicate that the freeze-thaw durability of high strength concrete is markedly affected by the coarse aggregate source, mixing temperature and curing conditions.
혼화재 종류 및 치환율에 따른 고강도콘크리트의 중성화와 건조수축에 관한 실험적 연구
권영진,Kwon, Young-Jin 한국건축시공학회 2003 한국건축시공학회지 Vol.3 No.3
Carbonation and drying shrinkage are very important properties of concrete, that can cause concrete to lower its capacity and spall. But the research on them in high strength concrete is very poor. In this study, to estimate influences of W/B, the kind of admixture, the replacement ratio of admixture, fineness of blast furnace and etc. on drying shrinkage and carbonation, we make experiment with 3 levels(28, 35, 55%) of W/B, 3 kinds(blast-furnace slag, fly-ash, silica-fume) of admixture, 3 levels of the replacement ratio, 3 levels(4000, 6000, 8000cm2/g) of fineness of blast-furnace slag and 2 kinds of curing condition. As the results, compressive strength of concrete was decreased, as W/C was increased and the replacement ratio of admixture was increased. Drying shrinkage was increased, as W/B was higher, the replacement ratio of admixture was increased and fineness of blast-furnace slag was decreased. And carbonation was increased, as W/B ratio was higher, the replacement ratio of admixture was increased.
증점제를 사용한 고유동콘크리트의 건조수축 및 중성화에 관한 연구
권영진,Kwon, Young-Jin 한국건축시공학회 2003 한국건축시공학회지 Vol.3 No.3
This study investigated about several mix factors came up to drying shrinkage and carbonation of high flowing concrete using viscosity. The results are as follows; Drying shrinkage ratio of high flowing concrete using viscosity showed higher for early age, but lower than normal concrete as long age. Also, drying shrinkage ratio and reduction ratio of mass showed higher and relative dynamic modulus of elasticty showed lower as W/C was higher generally. And in case of high flowing concrete using viscosity, carbonation wasn't confirmed without the kinds of cement and viscosity except 50C.
권영진 ( Kwon Young-jin ) 한국구조물진단유지관리공학회 2004 한국구조물진단유지관리공학회 논문집 Vol.8 No.2
적산온도은 시멘트 수화의 결과로서 시간이 경과함에 따라 콘크리트 강도가 얻어진다는 것으로 콘크리트의 강도는 시멘트의 수화반응과 관계가 있다. 시멘트의 수화반응은 온도와 경과시간에 큰 영향을 받는다. 따라서 본 연구에서는 콘크리트 강도예측에 있어서 양생시간과 온도의 함수인 적산온도와 고강도콘크리트 강도의 상관성을 검토하고자 하였다. The maturity concept is based on the fact that concrete gains strength with time as a result of the cement hydration and, thus the strength of concrete is related to the degree of hydration of the cement in concrete. The rate of hydration, as in any chemical reaction, depends primarily on the concrete temperature during hydration. Therefore, the aim of the study is to investigate of the correlation between strength of high-strength concrete and maturity that is expressed as a function of an integral of the curing period and temperature.
건축법의 연기제어에 관한 주요변천사항과 현황의 문제점 및 개선방향
권영진(Young-Jin Kwon) 한국화재소방학회 2022 한국화재소방학회 학술대회 논문집 Vol.2022 No.추계
최근 구획화재특성에 영향을 미치는 다양한 인자들 중 연기유동에 대한 이론과 연기제어설계에 관한 재검토가 요망되고 있다. 국내의 경우 연기제어에 관한 기준은 크게 건축법과 소방법으로 나누어지고 있으나, 이 두 가지 법률에 대한 연계체계가 매우 미비하고 그 역할이 모호하다고 판단된다. 특히 건축구조물의 초고층화, 초대형화, 지하심층화 및 다중이용시설 등이 증가하는 현 상황에서 향후 화재위험성은 더욱 증대될 것이며 특히 초고층 복합건축물을 연결시키는 지하 대 공간 등에서의 화재는 향후 테러와의 관련성도 매우 큰 분야로서 연기제어에 대한 기술적 기반이 시급한 분야로 평가된다. 이러한 관점에서 소방법(제연)의 역할과 건축법(배연)의 역할이 분명하게 나뉘어져야 하나 현행 건축법의 경우에는 설계방법과 배연의 효과 등에 대한 내용이 불투명할 뿐만 아니라 소방의 제연과는 어떠한 형태로 서로 공존하는 가에 대한 구체적인 방법론이 없는 상황으로 사료된다. 따라서 건축법에서의 연기제어의 역할과 성능적인 피난안전설계의 근본적인 재검토가 이루어져야 할 시점으로 보이며 현행과 같이 건축법에서의 연기제어 및 피난안전설계에 대한 명확한 역할이 제시되지 못하고 소방법에서의 연기제어와 공조가 이루어지지 못할 경우에는 연기제어의 미비에 따른 대규모 인명피해도 예상될 정도로 아주 심각한 상황으로 판단된다. 이러한 관점에서 소방의 제연과 건축의 배연에 대한 상호균형을 이룰 수 있는 방안을 위한 특별세션을 기획하였고 앞으로의 연기제어에 대한 건축법과 소방법의 상호 관련을 도모하고자 한다.
무선 센서네트워크 기반 차량검지 시스템을 위한 저전력 TDMA MAC 프로토콜
권영진(Young Jin Kwon),최진규(Jin Kyu Choi),김태홍(Tae Hong Kim) 한국전자통신학회 2018 한국전자통신학회 논문지 Vol.13 No.5
지자기 센서 기반의 차량검지 시스템에서 지자기 센서 노드는 복잡한 케이블 연결 없이 쉽게 도로에 매설할 수 있도록 무선 통신을 이용하는 방식으로 설계되며, 시스템의 유지보수 비용을 줄이기 위해서는 도로에 매설된 지자기 센서 노드의 배터리 수명을 늘리는 것이 중요하다. 본 논문에서는 차량검지 시스템에서의 차량검지 정보의 실시간성을 보장하면서 지자기 센서 노드의 에너지 소모를 줄일 수 있는 저전력 TDMA 프로토콜을 제안한다. 성능분석에서는 실제 지자기 센서 기반 차량검지 시스템에서의 지자기 센서 노드의 전력 소모를 측정하였으며, 시스템의 시간동기를 유지하면서도 배터리 효율을 62% 향상함으로써 약 5년간 배터리 교체 없이 사용할 수 있음을 검증하였다. The geomagnetic sensor nodes are usually designed with wireless communication and battery for easy installation on the road without cable connection and wiring. To minimize operation cost of a system, it is important to prolong the battery lifetime of the geomagnetic sensors installed on the road. In this paper, we propose a low-power TDMA MAC protocol that reduces energy consumption while guaranteeing the real-time vehicle detection information in the vehicle detection system. The performance evaluations are conducted through a real testbed of a vehicle detection system, and it proves that the proposed low-power protocols provides 5 year lifetime by improving energy efficiency up to about 62%.