http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
An S-locus receptor-like kinase in plasma membrane interacts with calmodulin in <i>Arabidopsis</i>
Kim, Ho Soo,Jung, Mi Soon,Lee, Kyunghee,Kim, Kyung Eun,Yoo, Jae Hyuk,Kim, Min Chul,Kim, Doh Hoon,Cho, Moo Je,Chung, Woo Sik Elsevier 2009 FEBS letters Vol.583 No.1
<P><B>Abstract</B></P><P>Calmodulin-regulated protein phosphorylation plays a pivotal role in amplifying and diversifying the action of calcium ion. In this study, we identified a calmodulin-binding receptor-like protein kinase (CBRLK1) that was classified into an S-locus RLK family. The plasma membrane localization was determined by the localization of CBRLK1 tagged with a green fluorescence protein. Calmodulin bound specifically to a Ca<SUP>2+</SUP>-dependent calmodulin binding domain in the C-terminus of CBRLK1. The bacterially expressed CBRLK1 kinase domain could autophosphorylate and phosphorylates general kinase substrates, such as myelin basic proteins. The autophosphorylation sites of CBRLK1 were identified by mass spectrometric analysis of phosphopeptides.</P><P><B>Structured summary</B></P><P>MINT-6800947:<I>CBRLK1</I> (uniprotkb:Q9ZT06) and <I>AtCaM2</I> (uniprotkb:P25069) <I>bind</I> (MI:0407) by <I>electrophoretic mobility shift assay</I> (MI:0413)</P><P>MINT-6800966:<I>AtCaM2</I> (uniprotkb:P25069) and <I>CBRLK1</I> (uniprotkb:Q9ZT06) <I>bind</I> (MI:0407) by <I>competition binding</I> (MI:0405)</P><P>MINT-6800930:<I>CBRLK1</I> (uniprotkb:Q9ZT06) <I>binds</I> (MI:0407) to <I>AtCaM2</I> (uniprotkb:P25069) by <I>far Western blotting</I> (MI:0047)</P><P>MINT-6800978:<I>AtCaM2</I> (uniprotkb:P25069) <I>physically interacts</I> (MI:0218) with <I>CBRLK1</I> (uniprotkb:Q9ZT06) by <I>cytoplasmic complementation assay</I> (MI:0228)</P>
미세각막절개 백내장 수술 후 낭내 삽입한 일체형 비구면 인공수정체의 임상 결과
김윤전,전미현,고동아,김재용,김명준,차흥원,Yoon Jeon Kim,Mi Hyun Cheon,Dong Ah Ko,Jae Yong Kim,Myoung Joon Kim,Hung Won Tchah 대한안과학회 2013 대한안과학회지 Vol.54 No.4
Purpose: To evaluate the stability and optical performance of the newly developed single-piece aspheric intraocular lens (IOL) by comparing the clinical outcome of the aspheric IOL with the new optic profile design (HOYA iSert, HOYA iMics) and the aspheric IOL (Akreos MI60), which has been proven effective and safe. Methods: iSert, iMics, and MI60 were inserted into 55 eyes, 60 eyes, and 50 eyes, respectively, after microincision phacoemulsification cataract surgery. Best corrected visual acuity (BCVA), refraction in spherical equivalent, anterior chamber depth (ACD), total higher order aberration (HOA), contrast sensitivity, and surgically induced astigmatism (SIA) were measured and each IOL was evaluated on the functional stability, anterior-posterior stability, centration in the capsular bag, and quality of vision. Results: No statistical differences in preoperative and postoperative BCVA among the 3 IOL groups were observed, however, MI60 showed significant myopic shift postoperatively. Anterior-posterior stability assessed with postoperative change in refractive error and ACD was slightly lower in the MI60 group. In terms of vision quality, while total aberration, total HOA, coma aberration, and contrast sensitivity for the 3 IOLs were not different significantly, spherical aberration of the MI60 group was higher than the other groups at 6 months postoperative. SIA was significantly increased in eyes implanted with iSert than in eyes with iMics or MI60 at 1 month postoperatively, however, the differences were no longer evident after 3 months postoperatively. Conclusions: The new aspheric IOLs, iSert and iMics, showed good stability and visual outcome equal to MI60 at the 6-month postoperative follow-up.
Kyu-shik Jeong,정원일,Jae-yong Chung,Mi-young An,Chae-yong Jung,Gyoung-jae Lee,Jong-soo Kang,Byeong-cheol Kang,Young-heun Jee,Bruce H Williams,Young-oh Kwon,Da-hee Jeong 대한수의학회 2003 Journal of Veterinary Science Vol.4 No.2
Cirrhosis Occurring in a Young Woodchuck (Marmota monax) Due to Vertical Transmission of Woodchuck Hepatitis Virus (WHV)Da-hee Jeong, Won-il Jeong, Jae-yong Chung, Mi-young An, Chae-yong Jung, Gyoung-jae Lee1, Jong-soo Kang1, Byeong-cheol Kang2, Young-heun Jee3, Bruce H Williams4, Young-oh Kwon5 and Kyu-shik Jeong*College of Veterinary Medicine, Kyungpook National University, Daegu 702-701, Korea1Shinwon Scientific Co., LTD, Research Institute, Suwon, Korea2Clinical Research Institute, Seoul National University, Seoul 110-744, Korea3College of Veterinary Medicine, Jeju National University, Jeju 690-756, Korea
박지훈,이상혁,김희,이재호,박성재,지삼룡,양성연,박은택,이연재,설상영,정정명,강미선 白中央醫療院 2005 仁濟醫學 Vol.26 No.1
Fungus such as Candida albicans is a normal flora that is frequently found in the oral cavity, gastrointestinal tract, genitourinary tract, vaginal mucosa in a normal person. However, candida can cause opportunistic infection in an immune compromised host. Candidiasis has broad spectrum of disease from mucocutaneous infection to invasive or disseminated infection. But, it is rarely reported that candida is associaed with gastrointestinal tract disease in a healthy adult. The case of gastric ulcer associated with candida particularly in a health adult is reported with relevant literature.
향기요법이 통증을 주소증으로 입원한 환자의 수면장애에 미치는 영향
박수곤 ( Soo Gon Park ),양미성 ( Mi Sung Yang ),김오영 ( Oh Young Kim ),조희근 ( Hee Guen Jo ),최진봉 ( Jin Bong Choi ),김선종 ( Sun Jong Kim ),설재욱 ( Jae Uk Sul ) 한방재활의학과학회 2010 한방재활의학과학회지 Vol.20 No.4
Objectives :The purpose of this study is to investigate the effects of aroma therapy on sleep disorder patients with musculoskeletal pain. Methods :The 44 patients were divided into 2 groups: Experimental group(Exp. group) was treated with aroma therapy and control group was treated except aroma therapy. To evaluate the efficiency of aroma therapy, the Korean sleep scale A(Jin-Joo Oh, Mi-Soon Song, Sin-Mi Kim. 1998) and visual analogue scale(VAS) were applied before treatment and after 5 days treatment. Results :1. The Experimental group has improved statistical significance in sleep disorder score as compare to the control group. 2. The improvement of sleep disorder score of Exp.group has difference according to impression. 3. The improvement of sleep disorder has an effect on pain decrease. Conclusions :Aroma therapy has effects of improvement on sleep disorder with musculoskeletal pain.
금 합금 보철물의 교합면 삭제로 인한 임플란트-골 계면으로의 열전달에 관한 연구
조재영,강선녀,정창모,윤미정,허중보,전영찬 대한치과보철학회 2012 대한치과보철학회지 Vol.50 No.1
연구 목적: 임플란트-골 계면에서 발생하는 과도한 열은 골유착을 저해하여 임플란트의 실패를 유발한다. 이에 이번 연구에서는 임플란트 금 합금 보철물의 교합면 삭제시 임플란트-골 계면으로의 열전달 양상과 냉각 방식의 효율성을 알아 보고자 하였다. 연구 재료 및 방법: 온도 감지 장치 제작을 위하여 Internal cone 연결형태의 임플란트에 16개의K형 열전대를 부착하여 아크릴릭 레진에 포매하였다. 치과용 금 합금과 주조용 abutment를 사용하여 교합면에 3개의 요철을 가지는 시편을 10개 제작하였고, 연결 나사를 이용하여 임플란트와 연결한 뒤 온도 감지 장치를 37℃로 유지되는 수조에 위치시켰다. 저속 핸드피스와 green stone bur를 이용하여 30초 동안 보철물의 요철을 삭제하였는데, 무냉각군, 공기 냉각 군, 물 분사 냉각 군으로 나누어 요철을 삭제하였다. 보철물이 삭제 되는 동안 임플란트의 부위별로 온도가 0.05초 간격으로 기록되었고, 삭제를 멈춘 뒤에도 무 냉각 군의 경우 임계 온도인 47℃ 이하로 온도가 하강할 때까지, 공기 냉각군과 물 분사 냉각군의 경우 삭제 중단 후 30초 동안 추가로 온도를 기록하였다. 냉각 방식에 따른 임플란트-골 계면의 온도를 알아보고, 임플란트의 부위별 온도변화의 유의차를 알아보기 위하여 one-way ANOVA를 실시하였고, Turkey HSD 이용하여 95% 유의수준에서 사후 검증하였다. 결과: 무 냉각 군은 임플란트-골 계면의 온도가 47℃ 이상으로 상승하였으며, 임플란트의 경부에서 유의하게 높은 열이 측정되었다(P>.05). 공기냉각군과 물분사 냉각군은 임플란트-골 계면의 온도가 47℃ 이하로 유지되었다. 무 냉각 군에서 임플란트 경부의 온도가 47℃에 도달되는 데는 약 10.8 ± 1.5초가 소요되었다. 공기 냉각 군과 물 분사 냉각 군 사이에서는 임플란트-골 계면 온도의 유의차가 없었다(P>.05) 결론: 이상의 결과로부터 임플란트 금 합금 보철물의 교합면 삭제 시, 임플란트 주위 조직에 위해를 가할 수 있는 임계 온도 이상의 열이 발생했음을 알 수 있었으며, 냉각방식은 공기 냉각과 물 분사 냉각 모두 효과적이라고 생각된다. PURPOSE. The purpose of this study was to analyze temperature change along the implant-bone interface induced by grinding the occlusal surface of implant gold prosthesis and to compare the temperature generated by grinding of prosthesis with different cooling methods. MATERIALS AND METHODS. The experimental gold prostheses were fabricated with dental gold alloy and castable abutment. The prostheses had 3 cylindrical protrusions on the occlusal surface with 1mm in height. Temperature was measured using 16 thermocouple wires attached to the implant fixture surface and the fixture was embedded in an acrylic resin block inside the 37℃ water bath. Cylinders were grinded for a period of 30 second with a low-speed handpiece with green stone point. One cylindrical protrusion was grinded without cooling, the second one was grinded with air blow, and the third one was grinded with water-spray. RESULTS. The mean maximum temperature was measured more than 47℃ of the implant and the maximum temperature was measured at the cervical portion of the implant in the group without cooling. There was statistically significant difference between the group without cooling and the groups with cooling (P<.05). However, there was no significant difference at all portion of implant in the groups with cooling (P>.05). CONCLUSION. The results of this study support that the grinding of implant gold prosthesis without cooling may damage the peri-implant tissue. The continuous use of air blow and water-spray adjacent to prosthesis during the grinding of implant gold prosthesis may prove to be beneficial for cooling of the implant.