http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
홍상범(Sang-Beom Hong),최준호(Jun-Ho Choi) 대한전기학회 2019 전기학회논문지 Vol.68 No.1
Combined Cycle Unit (CC) generates the primary power from the Gas Turbine(GT)and supplies the remaining heat of the GT to the Steam Turbine (ST) to generate the secondary power from the ST. It plays a major role in terms of energy efficiency and Load Frequency Control(LFC). Incremental Heat Rate (IHR) curves of economic dispatch(ED) of CC is applied differently by GT/ST combination. But It is practically difficult because of performance test by all combinations. This paper suggests a reasonable method for estimating IHR curves for partial combinations(1 : 1∼ (N - 1) : 1) using IHR curves when operating with GT alone(1:0) and with all (N : 1) combinations of CC .
만성폐쇄성폐질환 환자 사망 원인 - 한 3차 병원 연구
김범준 ( Beom Jun Kim ),홍상범 ( Sang Bum Hong ),심태선 ( Tae Sun Shim ),임채만 ( Chae Man Lim ),이상도 ( Sang Do Lee ),고윤석 ( Youn Suck Koh ),김우성 ( Woo Sung Kim ),김동순 ( Dong Soon Kim ),김원동 ( Won Dong Kim ),오연목 ( Yeo 대한결핵 및 호흡기학회 2006 Tuberculosis and Respiratory Diseases Vol.60 No.5
연구배경 : 만성폐쇄성폐질환(COPD)은 45세 이상의 성인에서 국내 유병률 17.2%로 주요 질환이다. 하지만, 국내 COPD 환자의 사망원인에 대한 연구는 불충분한 상황이다. 이에 국내 COPD 환자 사망원인에 대해서 알아보고자 서울아산병원 의무기록을 후향적으로 조사하였다. 방법 : 2003년 1년간 서울아산병원에서 COPD로 진료한 1,078명의 사망여부를 통계청에 의뢰하여 총 사망자 88명을 얻었고 이중 폐결핵 후유증, 기관지확장증, 폐암 등 암 환자를 제외한 후 남은 28명의 COPD 환자 대상으로 사망원인을 분석하였다. 결과 : COPD 환자의 사망원인은 폐렴 등 호흡기 원인이 16명 (57%), 심장 원인 5명 (18%), 급사 3명 (11%), 기타 4명 (14%) 등이었다. 서울아산병원 내에서 사망한 환자와 외에서 사망한 환자의 호흡기 관련 사망이 각각 83%(10명/12명)과 38%(6명/16명)이었다 (P=0.05) FEV1이 50%예측치보다 큰 환자와 작은 환자의 호흡기 관련 사망은 각각 43%과 55%이었다 (P=0.89). 결론 : 국내 3차 병원에서 진료하는 COPD 환자의 사망 원인은 폐렴 등 호흡기 원인 다수를 차지한다. Background : Although 17% of Korean adults over the age of 45 years have chronic obstructive pulmonary disease (COPD), there is only limited data on the cause of death in COPD patients in Korea. Therefore, this retrospective study was performed to examine the cause of death in COPD patients at a referral hospital in Korea. Methods : The medical records of 28 deceased patients diagnosed as COPD in Asan Medical Center from January to December 2003 were reviewed patients had died in Asan Medical Center and 16 patients had died outside the hospital. The Korean National Statistical Office confirmed 88 deceased patients out of 1,078 patients diagnosed as COPD in Asan Medical Center in 2003. After excluding those with tuberculous destroyed lung, bronchiectasis, and lung cancer, 28 COPD patients were evaluated. Results : The causes of death were pulmonary disease including pneumonia in 16 patients (57%), cardiac disease in 5 patients (18%), sudden death in 3 patients (11%), and other causes in 4 patients (14%). The cause of death was pulmonary disease in 83% (10 out of 12 patients) and 38% (6 out of 16 patients) of patients who died in Asan Medical Center and outside the center, respectively (P=0.05). The cause of death was pulmonary disease in 43% of patients with FEV1 more than 50% of the predicted value and in 55% of patients with FEV1 less than 50% of the predicted value (P=0.89). Conclusion : Pulmonary disease is the leading cause of death in COPD patients in Korea. (Tuberc Respir Dis 2006; 60: 510-515)
박현주(Hyun-Ju Park),홍상범(Sang-Beom Hong),최혁조(Hyuk-Jo Choi) 한국정보전자통신기술학회 2017 한국정보전자통신기술학회논문지 Vol.10 No.3
최근 급속한 경제성장에 따른 인구의 도시 집중화 현상이 발생하고 있으며 이로 인해 도시 건물의 밀집화, 고층화, 용도의 다변화에 따라서 화재 및 사고·범죄의 위험이 상당히 증가하는 추세이다. 이런 협소거주공간은 무창층의 특성을 가지고 있어 화재 발생시 급격한 연기확산 속도에 따른 거주자의 피해가 큰 게 현실이며 소방작전에 사용되는 무선통신의 전파 투과율 및 송달거리 또한 건축자재 및 건축물의 형태에 따라 통신 성능의 차이가 발생한다. 따라서 효율적인 소방작전을 위해 본 논문에서는 협소거주 공간의 건물 자재(철근콘크리트벽체, 샌드위치 패널 벽체, 경량칸막이 석고보드 벽체, 유리 출입문, 방화철문) 및 구조 특성을 분석하고 이에 따른 무선 통신의 전파(주파수 대역 424MHz, 2.4GHz) 투과율 및 송달거리 측정실험을 통해 최적의 소방작전을 위한 협소거주 공간의 통신 환경 솔루션을 도출하였다. Recently, Population has been concentrated in cities due to rapid economic growth.As a result, urban buildings are becoming more dense, high-rise, and diversified. The shape of these urban buildings increases the risk of fire, accidents and crime. The narrow living space has the characteristic of the unchanged floor. In case of a fire, the living space of the narrow residence is large in the damage because the smoke diffusion rate is fast. The radio wave transmittance and transmission distance of wireless communication used in fire fighting operations vary depending on the type of building materials and buildings. Therefore, this paper analyzes the building materials and structural characteristics of the narrow residential space for efficient fire fighting operations. We have developed a communication environment solution for a narrow residential space for the optimal fire fighting operation through the measurement of the radio wave transmittance and the transmission distance of the wireless communication.