RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        한국특산종 외대잔대(Adenophora racemosa)의 분자계통학적 위치

        지윤의,문병철,이아영,천진미,추병길,김호경 韓國藥用作物學會 2010 한국약용작물학회지 Vol.18 No.6

        Adenophora racemosa is recently reported as a new Korean endemic plant species. However, the phylogenetic relationship of this genus has been controversial due to the morphological similarity and frequent morphological change of aerial parts. To verify the phylogenetic position of Adenophora racemosa and phylogenetic relationship of genus Adenophora, we analyzed the internal transcribed spacer (ITS) sequence of nuclear ribosomal DNA (nrDNA) and random amplified polymorphic DNA (RAPD) using 21 individual of 6 Adenophora species, A. verticillata, A. divaricata, A. racemosa, A. remotiflora, A. stricata and A. tetraphylla. In comparative analysis of the nrDNA-ITS sequences, we could not found not only any species specific nucleotide sequence but also could not estimated their inter or intra species. In the phylogenic analysis based on the RAPD derived DNA polymorphism, Adenophora species were classified into four groups by clustering analysis of the UPGMA. These results suggest that the DNA fingerprinting based on RAPD is more suitable than nrDNA-ITS sequence for the phylogenetic analysis of Adenophora species.

      • KCI등재
      • KCI등재

        금산 진악산의 산림군락 분류 및 구조 분석

        지윤의 ( Ji Yun Ui ),이미정 ( Lee Mi Jeong ),김효정 ( Kim Hyo Jeong ),이규석 ( Lee Gyu Seog ),이선 ( Lee Seon ),송호경 ( Song Ho Gyeong ) 한국환경생물학회 2003 환경생물 : 환경생물학회지 Vol.21 No.3

        본 연구는 충남 금산군에 위치한 진악산 산림식생을 대상으로 식물사회학적 방법으로 산림군락을 분류하고 방형구법으로 임분 특성을 분석하였다. 진악산의 26개 조사구를 분석한 결과, 산림군락은 신갈나무군락, 굴참나무군락, 갈참나무군락 및 소나무군락으로 구분되었으며, 피도율은 교목층이 79.4%, 아교목층이 27.6%, 관목층이 37.0%, 초본층이 31.1%의 순으로 나타났다. DBH 2㎝ 이상의 수목을 대상으로 중요치를 분석한 결과는 신갈나무가 45.51, 소나무가 44.17, 굴참나무가 27.56, 졸참나무가 26.78, 갈참나무가 20.81, 벚나무가 15.58 등의 순으로 나타났으며, 흉고직경급을 분석한 결과 신갈나무, 굴참나무, 갈참나무, 소나무는 5㎝ 이하의 어린 개체와 15㎝ 이상의 큰 개체는 적고 5~15㎝의 중간 개체가 많아 이들이 당분간 우점할 것으로 판단된다. This study was carried out to analyze forest vegetation of Jinaksan in Geumsan, Chungnam Province. Employing the releve method of Braun-Blanquet, 26 plots were sampled in forest of Jinaksan. The communities were classified into Quercus mongolica, Quercus uariabilis, Quercus aliena, and Pinus densiflora communities. Coverage rate was 79.4% in tree layer, 27.6% in subtree layer, 37.0% in shrub layer, 31.1% in herb layer, respectively. The importance values were 45.51 in Q. mongolica, 44.17 in P. densiflora, 26.56 in Q. uariabilis, 26.78 in Q. serrata, 20.81 in Q. aliena, and 15.58 infPrunus serrulata var. spontanea, respectively. Most of the DBH in the Q. mongolica, Q. variabilis, Q. aliena, and P. densiflora was between 5 ㎝ and 15 ㎝. Therefore, Q. mon-golica, Q. variabilis, and Q. aliena will be dominant species in the study area for several decades.

      • KCI등재
      • KCI등재

        폐암 정위체부방사선치료 시 고정기구(frame) 사용 유무에 따른 셋업 정확성 평가

        지윤,장경환,조병철,곽정원,송시열,최은경,이상욱,Ji, Yunseo,Chang, Kyung Hwan,Cho, Byungchul,Kwak, Jungwon,Song, Si Yeol,Choi, Eun Kyung,Lee, Sang-wook 한국의학물리학회 2015 의학물리 Vol.26 No.4

        본 연구의 목적은 폐암의 정위체부방사선 치료 환자에 대하여 정위체부고정기구 사용 유무에 따른 셋업 정확성을 비교 평가하고자 한다. 본원에서 정위체부방사선치료를 받은 총 40명의 환자를 대상으로, 정위체부고정기구를 기반으로 한셋업 방식의 환자군 20명과 고정기구 없이 Wing board를 사용한 환자군 20명으로 구분하여 각 셋업오차를 비교, 분석 하였다. 폐암의 정위체부방사선치료는 총 4~5회에 걸쳐 48~60 Gy 조사되었다. 매 치료 전, 먼저 레이저를 이용하여 환자를 치료중심점에 위치시킨 후 On-board kV 영상장치를 이용하여 2차원 직각영상을 얻어 척추를 기준으로 환자의 위치를 조정한 다음, 3차원 체적 영상을 획득 하여 종양의 위치를 치료중심점에 일치시키고, 마지막으로 호흡에 의한 종양의 위치 확인 및 조정을 위해 2차원 직각 투시영상을 이용하였다. 각 과정에서 얻은 테이블 이동 및 회전 값을 조사하여, 셋업 군별로 계통오차 및 랜덤오차를 구하였다. 고정기구 사용유무에 따른 통계적 유의성을 검증하기 위하여 계통오차에 대한 t-test 시행을 하였고, 셋업의 재현성의 차이를 보기위해 랜덤오차에 대한 F-test를 시행하였다. 나아가 이러한 셋업 방식의 차이가 셋업 여유분의 크기 결정에 영향이 있는지 여부를 평가하기위해 치료계획체적의 여유분을 계산하여 두 방식의 차이를 비교하였다. 정위체부 고정기구를 사용했을 때의 셋업 오차는 수직방향, 길이방향, 수평방향으로 각각 $0.05{\pm}0.25cm$, $0.20{\pm}0.38cm$, $0.02{\pm}0.30cm$이었다. 반면에, Frameless immobilizer을 사용한 단순 고정방법을 사용했을 때의 셋업 오차는 수직방향에서만 통계적으로 유의하게 $-0.24{\pm}0.25cm$으로 증가함을 보였으나, 길이방향, 수평방향에 대해서는 각각 $0.06{\pm}0.34cm$, $-0.02{\pm}0.25cm$의 작거나 비슷한 결과값을 보였다. 정위체부 고정기구를 사용했을 경우, 수직방향, 수직방향 및 길이방향으로의 여유분은 각각, 0.67 cm, 0.99 cm, 0.83 cm였고, Frameless immobilizer시 수직방향으로 0.75 cm, 길이방향으로 0.96 cm, 수평방향으로 0.72 cm로써 수평방향에서 최대 0.11 cm 차이가 남을 알 수 있었다. 결론적으로 정위체부고정기구를 사용하는 것이 환자 자세 재현성을 향상시켜 셋업 오차를 환자의 전후, 위아래 방향으로의 약 0.1~0.2 cm씩 줄일 수 있을 것으로 평가하였다. 다만 정위체부 고정기구 사용에 따른 시간 소요 및 치료절차의 복잡성에 비해 그 효과는 그리 크지 않았다. The purpose of this study was to evaluate the set up accuracy using stereotactic body frame and frameless immobilizer for lung stereotactic body radiation therapy (SBRT). For total 40 lung cancer patients treated by SBRT, 20 patients using stereotactic body frame and other 20 patients using frameless immobilizer were separately enrolled in each group. The setup errors of each group depending on the immobilization methods were compared and analyzed. All patients received the dose of 48~60 Gy for 4 or 5 fractions. Before each treatment, a patient was first localized to the treatment isocenter using room lasers, and further aligned with a series of image guidance procedures; orthogonal kV radiographs, cone-beam CT, orthogonal fluoroscopy. The couch shifts during these procedures were recorded and analyzed for systematic and random errors of each group. Student t-test was performed to evaluate significant difference depending on the immobilization methods. The setup reproducibility was further analyzed using F-test with the random errors excluding the systematic setup errors. In addition, the ITV-PTV margin for each group was calculated. The setup errors for SBF were $0.05{\pm}0.25cm$ in vertical direction, $0.20{\pm}0.38cm$ in longitudinal direction, and $0.02{\pm}0.30cm$ in lateral direction, respectively. However the setup errors for frameless immobilizer showed a significant increase of $-0.24{\pm}0.25cm$ in vertical direction while similar results of $0.06{\pm}0.34cm$, $-0.02{\pm}0.25cm$ in longitudinal and lateral directions. ITV-PTV margins for SBF were 0.67 cm (vertical), 0.99 cm (longitudinal), and 0.83 cm (lateral), respectively. On the other hand, ITV-PTV margins for Frameless immobilizer were 0.75 cm (vertical), 0.96 cm (longitudinal), and 0.72 cm (lateral), indicating less than 1 mm difference for all directions. In conclusion, stereotactic body frame improves reproducibility of patient setup, resulted in 0.1~0.2 cm in both vertical and longitudinal directions. However the improvements are not substantial in clinic considering the effort and time consumption required for SBF setup.

      • KCI등재

        치과용 초소형 X-선 튜브의 선량평가

        지윤,김연우,이레나,Ji, Yunseo,Kim, YeonWoo,Lee, Rena 한국의학물리학회 2015 의학물리 Vol.26 No.3

        의료용 x선 촬영 장치에 있어서 환자에게 피폭되는 선량이 가장 중요한 관심사 중의 하나이다. 본 연구팀에서는 전 세계 최초로 입안에 삽입이 가능한 초소형 x-선 영상 장치가 개발되었는데 이러한 영상장치를 임상에서 사용하기 위해서는 피폭 선량의 평가가 필수적이다. 따라서 본 연구에서는 신개념 치과용 영상장치의 선량을 평가하기 위하여 1) 돼지 턱뼈 팬텀을 직접 제작하여 영상의 질을 평가 하였고, 2) 실제 임상에서 사용가능한 촬영 조건을 결정하였으며, 3) 결정된 촬영 조건에서의 선량을 평가 하였다. 한국 식약처에서 제시하는 치근단 촬영에 대한 환자 선량 권고량(DRLs) 기준에 근거하여 새 개발 장비의 입사표면선량(ESD)와 면적선량(DAP) 측정 방법을 고안하고 각각의 선량 값을 측정하였다. 관전압이 45~55 kV, 관전류가 300 mA 까지 사용 가능한 xoft 사의 초소형 x선 튜브를 사용하였다. 사용된 검출기는 active area가 $72{\times}72mm$ 이고 픽셀 사이즈는 $48{\mu}m$ 이다. 제작된 돼지턱뼈 팬텀은 1 frame/sec의 조건하에 영상을 획득 하였으며, 촬영 조건 최적화를 위하여 관전류를 $20{\sim}80{\mu}A$로 변화시키면서 50 frame씩 영상을 획득하였다. 또한, 상용화 치과용 영상시스템(모델명: CS 2100, 제조사: Carestream Dental LLC 및 모델명: EXARO, 제조사: HIOSSEN)을 이용하여 돼지턱뼈 팬텀의 비교영상 평가를 시행하였다. CS 2100는 60 kV, 7 mA (노출시간:0.125 s)로 하였으며, EXARO는 60 kV, 2 mA로 설정하였다. 선량 평가는 광자극 형광 선량계를 이용하여 입사표면선량을 측정하였으며, 팬텀은 PMMA 재질의 제작된 원통형 팬텀을 이용하였다. 선량계는 팬텀 표면상의 조사야 내부에 2개 및 소스와의 5 cm 거리상에 1개를 위치하여 측정하였다. 빔 조사 조건은 51, 101, 141, $196{\mu}As$로 설정하였다. 면적선량은 소스와 검출기간의 거리가 5 cm 위치에 배치하여 측정하였으며, 이 때 촬영조건은, 관전류 41, 99, 144, 207, $276{\mu}As$의 조건하에서 측정하였다. 임상에서 적용 가능한 관전압과 관전류는 X-선 세기 8000~9000인 지점에서의 관전류 값인 0.051 mAs 이다. 상용화 장비와 영상비교를 한 결과, 개발 장비의 조사야가 훨씬 작음에도 불구하고 치아 및 치아 주위 조직의 영상이 더 우수함을 확인하였다. 또한, 영상 최적화 조사조건인 $51{\mu}As$에서 입사표면선량(ESD)은 식약처 및 IAEA의 권고치보다 훨씬 낮은 1.369 mGy 이다. 조사야 내부의 선량 분포는 표준편차 5~10% 내외로 균일성이 우수 하였다. 측정된 면적선량(DAP)은 $82.4mGy*cm^2$으로 상용화 장비보다 조사야가 훨씬 작음에도 불구하고 식약처의 권고치보다 낮은 값을 보였다. 이러한 연구를 통해서 새 개발 장비의 영상의 우수성과 기존 장비 대비 방사선량에 대한 저감 효과를 확인 할 수 있었으며 치과 장비 개발에 있어서 X선 특성 연구에 대한 기술과 노하우를 축적할 수 있었다. Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

      • KCI등재

        외대잔대(Adenophora raoemosa J.Lee & S.Lee)개체군의 classification과 ordination 분석

        지윤의 ( Yun Ui Ji ),문병철 ( Byeong Cheol Moon ),이야영 ( A Yeong Lee ),윤태숙 ( Tae Sook Yoon ),송호경 ( Ho Kyung Song ),추병길 ( Byung Kil Choo ),김호경 ( Ho Kyoung Kim ) 한국환경보건기술학회(구 한국환경복원녹화기술학회) 2009 한국환경복원기술학회지 Vol.12 No.6

        This study was carried out to investigate vegetation structure and soil properties of Adenophora racemosa population distributed in Jeombongsan, Seoraksan, Odaesan and Dutasan in Gangwon-do, Korea. From August 2007 until September 2009, 2 m × 2 m quadrate was established in native area of Adenophora racemosa in order to record a dominants and coverage, and soil factors at 22 sites. It was found that the altitude in the distributed areas for Angelica gigas population was 800 m or more. Adenophora racemosa population was classified into Rhododendron mucronulatum dominant population, Geranium var. hirsutum dominant population, Carex siderosticta dominant population and Aruncus dioicus var. kamtschaticus dominant population. In the site of study, soil pH, electrical conductivity, soil organic matter, available phosphorous, and exchangeable potassimn, exchangeable calcimn, exchangeable magnesium, exchangeable sodium concentration and total nitrogen were ranged from 5.0~7.1, 0.06~0.65dS/m, 0.96~8.94%, 12.3~32.8mg/kg, 0.12~0.89cmol+/kg, 0.34~10.08cmol+/kg, 0.1~l.4cmol+/kg, 0.02~0.29cmol+/kg and 0~8.4% respectively. According to the results of DCCA, Adenophora racemosa population were distributed in the high available phosphorous and exchangeable potassium, and Rhododendron mucronulatum dominant population was situated on low available potassium and high slope degree, Geranium var. hirsutum dominant population was high altitude, electrical conductivity and exchange magnesium, and Carex siderosticta dominant population and Aruncus dioicus var. kamtschaticus were distributed on high total nitrogen, organic matter, available phosphorous.

      • KCI등재

        Authentication of Akebia quinata DECNE. from its common adulterant medicinal plant species based on the RAPD-derived SCAR markers and multiplex-PCR

        문병철,지윤의,이영미,강영민,김호경 한국유전학회 2015 Genes & Genomics Vol.37 No.1

        Akebiae Caulis, ‘Mu`to¯ng’ in Chinese, refers tothe stem of Akebia quinata in the Korean modern pharmacopoeia. The stems of Aristolochia manshuriensis andClematis armandii have also been traditionally used forclinical purposes, and are often marketed as ‘Mu`to¯ng’under the names ‘Gua¯n-Mu`to¯ng and Chua¯n-Mu`to¯ng’,respectively. Furthermore, due to the morphological similarityof the herbal medicines, their correct identification bytraditional subjective methods is difficult. Therefore, todevelop a reliable method for discriminating these threeherbal medicines, we applied the tools of moleculargenetics, including random amplified polymorphic DNA(RAPD) and sequence characterized amplified region(SCAR) marker development using samples of Akebiaquinata, Akebia trifoliata, Aristolochia manshuriensis, andClematis armandii. By comparative analysis of RAPDpolymorphisms, we identified several potential PCR productsthat can be used to distinguish the herbal materials ofeach species. Using these RAPD products, we developedunique sequence characterized amplified region (SCAR)markers for determination of the species of plant materials;the products were 590 bp for A. quinata, 300 bp for A. trifoliata, 373 bp for A. manshuriensis, and 432 bp for C. armandii. Furthermore, we optimized SCAR markers forsimultaneous discrimination of the four species by multiplex-PCR. These markers allow efficient identification ofclosely related herbal medicines originating from Akebia,Aristolochia, and Clematis species, and have potential usesin preventing the distribution of adulterants, as they can beused to identify each species and distinguish them frominauthentic substitutes.

      • KCI등재

        X-선 튜브의 고전압 발생장치 제어에 관한 연구

        이순혁,지윤,최상규,이레나,Lee, Soonhyouk,Ji, Yun-Seo,Choi, Sang Gyu,Lee, Rena 한국의학물리학회 2014 의학물리 Vol.25 No.4

        The purpose of this study is to develope a control system for a small X-ray tube generator and investigate control methods for the X-ray generator. The small X-ray tube was developed for electronic brachytherapy, and thus, the new control method should be investigated, if the small X-ray tube is used for the imaging system. The Axxent S700 X-ray tube and the XF060NZZ485 high voltage generator were used to compose a X-ray imaging system and control board was developed by using AT90CAN128 MCU. The two control methods were investigated after tube voltage was set to 50 kV, one was filament current control method and the other was beam current control method. The former was subdivided into two methods according to the filament heating time, the 5 and the 10 seconds respectively. In the filament current method, the beam current did not rise up to the desired value, if the filament current had not been maintained for at least 10 seconds. The onset filament currents to generate beam current were varied from 1,300 to 1,350 mA and over 5 seconds were needed in order to reach the desired tube current value after beam current was generated. However, in the tube current control method, the beam current reached to the desired value without any time delay with the filament current of 1,500 mA. In this study, we found that the beam current control method was appropriate for the use of small X-ray tube developed for brachytherapy in the X-ray imaging system. 본 연구에서는 미국 Xoft 사에서 근접치료 장치(elecronic brachytherapy)를 목적으로 개발된 소형 X-선 튜브를 치과용 영상장비로 사용함에 있어서 고전압 발생장치의 제어용 장치를 개발하고 영상용 제어 방식으로 최적화하고자 한다. 연구에서 사용된 X-선 튜브와 고전압 발생 장치는 각각 Axxent S700과 XF060NZZ485를 사용하였고, AT90CAN128 MCU를 사용하여 제어보드를 제작하였다. 관전압을 50 kV로 고정한 후에 제어 방식에 따라서 필라멘트 전류 제어 방식과 관전류제어 방식으로 나누었다. 필라멘트 제어 방식은 다시 필라멘트 가열 시간에 따라서 5초와 10초의 두 가지로 나누어 실험하였다. 필라멘트 전류 제어 방식에서는 필라멘트 예열 시간이 10초 이상이 되지 않으면 설정된 관전류 값에 도달하기 어려웠고, 관전류가 발생하는 필라멘트 전류도 1,300~1,350 mA로 가변적이었으며, 관전류가 발생된 이후에도 설정된 목표 값에 도달하기 위해서는 약 5초 이상의 시간이 소요되었다. 하지만 관전류 제어 방식에서는 관전류가 설정된 목표 값에 시간 지연 없이 즉각적으로 도달하였으며 그 때의 필라멘트 전류 값은 1,500 mA였다. 본 연구에서는 소형의 X-선 튜브에 고전압을 안정적으로 공급하는 제어 장치를 개발하였고, 방사선 영상장비로 사용함에 있어서는 관전류 제어 방식이 적합함을 보였다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼