국가교정검사기관(액체유량)의 측정불확도 평가 및 비교연구
임기원 대한설비공학회 2000 설비공학 논문집 Vol.12 No.11
A proficiency test is one of programs which Korea Research Institute of Standards and Science(KRISS), as national metrology institute, is putting in operation for the mutual recognition arrangement. The Fluid Flow Group of KRISS evaluated the measurement capability for liquid flowmeter calibrator of the national calibration and test organizations. The uncertainty of national standard system was estimated in accordance with Guide to The Expression of Uncertainty in Measurement (ISO), and the turbine flowmeter, which was used for the round-robin test as a reference flowmeter, was characterized. The round-robin tests with the turbine flowmeter package were carried out in 1995 and 1999. The test results of the organizations and those of KRISS agreed within $\pm0.2$%. It is found thus that the organizations have the traceability of the national standard for liquid flow measurement.
임기원,Lim, Ki-Won 대한기계학회 2000 大韓機械學會論文集B Vol.24 No.10
A pipe prover is a flowmeter calibrator used in flow measurement field. Gravimetric and volumetric methods were applied to determine the basic volume of the pipe prover. Uncertainty of its basic volume measurement was evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainty of determining the basic volume was estimated from the sensitivity coefficient and the standard uncertainty of independent variables. It was found that the uncertainties of the weighing and volume measurements have dominant influence on that of the basic volume determination. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of the basic volume is shown clearly.
코리올리스 질량유량계의 유량측정에 영향을 미치는 인자에 관한 실험적 연구
임기원,이완규,Lim, Ki-Won,Lee, Woan-Kyu 대한기계학회 2003 大韓機械學會論文集B Vol.27 No.12
Coriolis mass flowmeter(CMF), which can measure the mass flow directly, is getting rapid attention for the industrial and custody transfer purpose. In order to study the characteristics and the applicability of CMF, it is tested with the national flow standard system. Two types of sensing tube, U-type and straight type, are employed in the test. Water, spindle oil and viscosity Standard Reference Material whose viscosities are 1, 20 and, 67 $\textrm{mm}^2$/s, respectively, are studied. It is shown that the linearity of CMF is getting deteriorated as the fluid viscosity increases, which is due to the zero drift and the relaxation time of the fluid. To test its applicability in the case of high pressured gas, it is calibrated using compressed air, It shows 1∼l.6 % deviations compared to the calibration results using water. It concludes that the fluid velocity in CMF should be lower than the sonic velocity. In addition, the effects of the vibration from the pipeline and pump on CMF as well as the long term stability are studied.
임기원,최종오,Lim, Ki-Won,Choi, Jong-Oh 대한기계학회 2003 大韓機械學會論文集B Vol.27 No.8
A national standard system was developed in order to calibrate and test the oil flowmeters for the petroleum field. A stop valve and a gyroscopic weighing scale were employed for the primary standard of the flow quantity. It is operated by the standing start and finish mode and the static weighing method. The model equation for uncertainty evaluation was based on the calibration principle of standard system. The sources of the uncertainties were quantified and combined according to the GUM(Guide to the Expression of Uncertainty in Measurement). It was found that the standard system had the relative expanded uncertainty of 0.04 % in the range of 18 - 350 ㎥/h. According to the uncertainty budget, the uncertainties of the fluid density and the volume of pipeline, which were temperature dependent, contributed 92% of final uncertainty in the oil flow standard system.
운동시 젖산대사의 변화 : 젖산수송체의 발현 monocarboxylate transporters and its implication
임기원,서혜정,이강우 한국운동영양학회 2001 Physical Activity and Nutrition (Phys Act Nutr) Vol.5 No.2
Skeletal muscle is the major producer of lactate in tissues, however its oxidative fibres also use lactate as a oxidative fuel. The stereoselective transport of L-lactate across the plasma membrane of muscle fibres has been shown to involve a proton-linked monocarboxylate transporter (MCT) similar to that described in erythrocytes, heart and skeletal muscle. This transporter plays an important role in the pH regulation of skeletal muscle. A family of eight MCTs has now been cloned and sequenced, and the tissue distribution of each isoform varies. Skeletal muscle contains both MCT1 (the only isoform found in erythrocytes but also present in most other cells) and MCT4. The latter is found in all fibre types, although least in more oxidative red muscles such as soleus, whereas expression of MCT1 is highest in the more oxidative muscles and very low in white muscles that are almost entirely glycolytic. MCT1 expression is increased in response to chronic stimulation and either endurance or explosive exercise training in rats and humans, both MCT1 and MCT4. The mechanism of regulation is not established, but does not appear to be accompanied by changes in mRNA concentrations. The increase of MCT1 protein by chronic or acute training in oxidative muscle could depend on exercise intensity, because more higher intensity could increase MCT1 protein. These facts suggest that high oxidative capacity for lactate in skeletal muscle would require to more higher exercise intensity, as well as above lactate threshold.