http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
이정기(J.G. Lee),김민규(M.K. Kim),김익수(I.S. Kim),정주영(J.Y. Jeong) 대한전기학회 2006 대한전기학회 학술대회 논문집 Vol.2006 No.10
It has been studied about the important consideration in designing and construction of the reliability assessment facilities including the combined testing system for simulating condition of acceleratedly deteriorated environment, which enable to test and evaluate the large-sized HV power apparatus without any disassembly up to transmission class in this paper. Also it is described simply about its ratings and main technical specifications and trial running of the system. To evaluate the performance characteristics against combined test condition for various power installation, especially for the polymer type insulators and kinds of bushings, brief investigation and an analysis of test objects and related international codes and standards have been conducted.
이정기(J.G. Lee),김민규(M.K. Kim),김익수(I.S. Kim),정주영(J.Y. Jeong) 대한전기학회 2006 대한전기학회 학술대회 논문집 Vol.2006 No.10
In this paper, there have been brief review about the important consideration in laboratory planning and construction of the reliability assessment infrastructure including 400 ㎸, 120 ㎸A AC test system, which enable to evaluate the HV long-term overcharged withstand performance for spacers using in Gas Insulated Switchgears up to transmission class. Also it is described simply about its trial running of the whole test system and its assessment example. To inform the founded national code, RS C 0084, and the procedure for getting a reliability assessment certificate issued by the government, brief description of the code and summation of test results have been conducted.
이정기(J.G. Lee),김민규(M.K. Kim),문인욱(I.W. Moon),정주영(J.Y. Jeong),김익수(I.S. Kim) 대한전기학회 2006 대한전기학회 학술대회 논문집 Vol.2006 No.7
In this paper, there have been brief review about the important consideration in laboratory planning and construction of the artificial pollution testing facilities including 300 ㎸, 1800 ㎸A AC test system, which enable to test and evaluate the UHV dielectric performance of power insulators up to transmission class. Also it is described simply about its trial running of the whole test system. To evaluate the performance characteristics against contamination for various power installation, especially for the insulators and kinds of bushings, brief investigation and an analysis of test objects and related international codes and standards have been conducted.