Use of the i-gelTM supraglottic airway device in a patient with subglottic stenosis -a case report-
이기화,Eun Su Kang,Jae Wook Jung,Jae Hong Park,Young Gyun Choi 대한마취통증의학회 2013 Korean Journal of Anesthesiology Vol.65 No.3
The airway management of patients with subglottic stenosis poses many challenges for the anesthesiologists. Many anesthesiologists use a narrow endotracheal tube for airway control. This, however, can lead to complications such as tracheal mucosal trauma, tracheal perforation or bleeding. The ASA difficult airway algorithm recommends the use of supraglottic airway devices in a failed intubation/ventilation scenario. In this report, we present a case of failed intubation in a patient with subglottic stenosis successfully managed during an i-gelTM supraglottic airway device. The device provided a good seal, and allowed for controlled mechanical ventilation with acceptable peak pressures while the patient was in the beach-chair position.