http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
이경진,정민정,Lee, Kyungjin,Jeong, Minjeong 대한한방소아과학회 2017 대한한방소아과학회지 Vol.31 No.2
Objectives The study was conducted to evaluate the recent treatment and study trends of tic disorder by reviewing domestic and international randomized controlled studies. Methods The acupuncture treatment on tic disorder randomized control study articles (published by June 10th, 2016) were selected from seven academic literature archives; NDSL, OASIS, KTKP, Pubmed, J-STAGE, CNKI, and CINAHL. Results Ten articles were identified after searching. These studies were analyzed by year, diagnostic criteria, intervention, evaluation criteria, treatment points, treatment effect, treatment duration, and 'Risk of Bias' assessment. Conclusions According to the articles, acupuncture was effective in treating tic disorder. However, additional well-designed randomized controlled studies will be required to justify the effectiveness of acupuncture treatment on tic disorder.
이경진,김민중,윤정호,정의원,김창성,최성호,조규성,채중규,김종관,Lee, Kyung-Jin,Kim, Min-Jung,Yun, Jeong-Ho,Jung, Ui-Won,Kim, Chang-Sung,Choi, Seong-Ho,Cho, Kyoo-Sung,Chai, Jung-Kiu,Kim, Chong-Kwan 대한치주과학회 2004 Journal of Periodontal & Implant Science Vol.34 No.3
tachment level was changed from $8.67{\pm}1.72mm$ to $7.00{\pm}1.60mm$ (control); from $8.93{\pm}2.23mm$ to $6.00{\pm}1.92mm$ (test); and bone probing depth was decreased from $10.20{\pm}1.90mm$ to $9.07{\pm}1.95mm$ (control); from $10.14{\pm}2.14mm$ to $7.43{\pm}2.06mm$ (test). This study indicates that treatment of periodontal intrabony defects with EMD is clinically superior to treatment without EMD (OFD alone) in every parameter evaluated. Within the limits of this study, the application of EMD in intrabony defects resulted in clinically significant gain of clinical attachment level and decrease of bone probing depth. And further controlled clinical studies are required to confirm the effectiveness of the EMD in the treatment of various osseous defects.
강판콘크리트(SC : Steel Plate Concrete) 보의 온도하중 재하 시 역학적 특성에 관한 실험연구
이경진,함경원,박동수,Lee, Kyung Jin,Ham, Kyung Won,Park, Dong Soo 한국강구조학회 2009 韓國鋼構造學會 論文集 Vol.21 No.5
This paper describes the experimental study that was conducted on the temperature characteristic and bending capacity of a steel-plate-reinforced concrete-wall module (SC module). The steel plate ratio and temperature loading parameters were tested, and the influence of these parameters on the moment-curvature relationship and on the bending strength of the SC module was investigated. The fundamental-structure characteristic result of every SC module that assumed practical use was investigated. In this study, the bending and flexural characteristics of SC structures were evaluated to verify the yielding and ultimate strength of the SC beam under thermal-loading conditions. 이 연구는 열하중이 발생하는 구조물에 강판 콘크리트구조를 적용하는 경우, 역학적 특성을 평가하기 위하여 수행하였다. 원자력발전소 구조물 중 사용후 핵연료 저장조 구조물과 같이, 구조물 내부는 지속적인 열 하중을 받고 구조물 외부는 대기에 노출되어 있는 경우, 구조물은내 외부의 온도차이로 인해서 열응력이 발생한다. 본 연구는 이러한 구조물에 강판 콘크리트 구조를 적용할 경우를 가정하여 보 형태의 강판 콘크리트 구조실험체에 온도하중을 재하한 상태에서 휨 내력 및 구조특성을 평가하고 추가적으로 실험체가 항복 시까지 하중을 가력하여 최종 휨내력을 평가하였다.
철근 콘크리트 구조와 강판 콘크리트 구조(Steel Plate Concrete) 이질접합부를 가진 보의 휨 하중 특성에 관한 실험연구
이경진,함경원,박동수,김우범,Lee, Kyung-Jin,Hahm, Kyung-Won,Park, Dong-Soo,Kim, Woo-Bum 한국강구조학회 2010 韓國鋼構造學會 論文集 Vol.22 No.5
본 연구는 철근콘크리트 구조와 강판 콘크리트 구조가 혼합되어 이질접합부가 있는 보형 구조물의 역학적 특성을 평가하기 위하여 수행하였다. 강판콘크리트 구조는 현재 국내와 일본, 미국 등에서 연구가 진행되고 있고, 대규모 산업설비에서 철근콘크리트 구조의 대안으로 실험연구가 수행되고 있다. 본 연구에서는 대규모 철근콘크리트 구조물에 강판 콘크리트 구조를 적용할 경우를 가정하여 보 형태의 구조물에 강판 콘크리트 구조와 철근 콘크리트 구조를 적용하여 이질접합부를 만들고, 면외하중을 파괴 시까지 가력하여 이질접합부를 가진 보형실험체의 휨 내력 및 구조특성을 평가하기 위하여 실험연구를 수행하였다. This paper describes the experimental study on the mechanical characteristics of a steel plate-reinforced concrete joint. As an alternative reinforced concrete structure, the SC modular construction method is widely used and studied in the field ofindustrial facility field. However, the structure characteristics of RC and SC joint are not yet studied completely. In this paper, the beam-type construction joint of RC and SC walls was made to simulate the application of SC module to the large RC structure. Also, an out-of-plane loading was applied to the test specimen in order to evaluate flexural strength and structural properties of the beam-type RC-SC joint.
RC 슬래브와 SC 벽 접합부의 전단마찰 거동에 관한 실험연구
이경진,황경민,김우범,Lee, Kyung Jin,Hwang, Kyeong Min,Kim, Woo Bum 한국강구조학회 2013 韓國鋼構造學會 論文集 Vol.25 No.6
본 연구에서는 RC 구조 슬래브와 SC 구조 전단벽이 만나는 접합부의 거동특성을 파악하고 RC구조 슬래브-SC구조 전단벽 이질접합부의 전단마찰내력을 평가하고 KEPIC SNG의 접합면 소요전단강도 기준의 안전율을 평가하기 위해 실험연구를 수행하였다. 연구결과, 접합면의 전단마찰내력은 약 300kN으로 나타났고, 변위가 증가할수록 철근의 내력분담이 증가하게 되며, 상부철근보다는 하부철근의 전단내력 분담율이 높은 것으로 나타났다. 하부철근을 구성한 경우에는 하부철근이 없는 실험체에 비해 40% 이상 전단내력이 증가하는 것으로 나타났다. In this study, the structure behavior of RC slab and SC shear wall connection was investigated. Also experimental study was performed to evaluate the factor of safety of demand shear connection strength in KEPIC SNG Standard. As a result, shear friction strength of connection was known about 300kN and shear strength of rebar increased according to the displacement increase. With the installment of the lower rebars, 40% shear strength increased compared to the non-rebar specimen.
강판콘크리트 구조 이질접합부의 면외 휨/면내 전단하중 특성에 관한 실험연구
이경진,황경민,함경원,김우범,Lee, Kyung-Jin,Hwang, Kyeong-Min,Hahm, Kyung-Won,Kim, Woo-Bum 한국강구조학회 2012 韓國鋼構造學會 論文集 Vol.24 No.2
본 연구는 L형, I형 실험체에 강판 콘크리트 구조와 철근콘크리트 구조를 적용하여 이질접합부를 만들고, 실험체에 반복하중을 파괴 시 까지 가력하여 면외 휨 내력 및 면내 전단 내력을 평가하고 구조특성을 검토하기 위해서 실험연구를 수행하였다.본 연구에서 면외 휨 성능실험은 접합부에서 정착부 수직철근이 인발되면서 파괴되었고, 면내 전단성능실험은 기초부에서의 휨 균열이 발생하여 파괴되었으며, 이론식과의 비교결과 최대 내력이 실험값/이론값의 결과가 면외 휨성능실험은 96%, 면내 전단성능실험은 82%의 값을 나타내었다. This paper describes an experimental study on the mechanical characteristic and behavior of a structure that has a joint between the reinforced concrete (RC) member and steel plate concrete (SC) member. An out-of-plane flexural test on an L-type test specimen and in-plane shear test on an I-type test specimen were carried out by means of repeated cyclic loading until their failure. Based on the results, the former showed pull-out failure mode of anchored vertical bars while the latter exhibited flexural failure mode of the basement member. These results reveal that the maximum capacity of the specimens is 96% and 82%, respectively, compared with the theoretical value.
이경진,조재원,권봉경,최준창,Lee, Gyeong-Jin,Jo, Jae-Won,Gwon, Bong-Gyeong,Choe, Jun-Chang 한국환경기술인연합회 2006 환경기술인 Vol.23 No.12
최근 수질환경보전법의 개정법률(안)에 의거하여 폐 · 하수종말처리장에 수온, pH, 생물학적산소요구량(BOD), 화학적산소요구량(COD), 총질소(TN), 총인(TP) 및 부유물질(SS)의 자동으로 측정할 수 있는 수질 자동측정기의 부착이 의무화될 예정에 있다. 그러나, 현재 전국적으로 화학적산소요구량 측정장비와 같이 일부 항목에 대한 자동측정장치는 설치 · 운영 중인 곳이 많이 있으나, 수질 TMS 설치 규정에 나와 있는 전 항목을 측정할 수 있는 장비가 설치되어 운영하는 곳은 극히 일부에 불과한 실정이다. 따라서, 수온, ph, 화학적 산소요구량(COD), 총질소(TN), 총인(TP), 부유물질(SS) 자동측정 장치를 설치하고, 무선통신(CDMA)방식을 이용하여 ‘방류수 수질 원격감시체계(TMS) 시범 운영'을 통하여, 측정 장비들에 대한 자료의 정확성, 신뢰성을 파악하여 설치된 장비들에 대한 성능을 사전에 평가하고, 수질 TMS 시스템에 대한 현장 적응 능력 및 안정성을 파악하여 실질적으로 운영되는 시점에 좀 더 정확하고 실용적인 시스템의 적용하고자 한다.
MANETs에서 정책기반 망 관리를 위한 Active PDP Discovery
이경진,송왕철,Lee Kyung-Jin,Song Wang-Cheol 한국통신학회 2006 韓國通信學會論文誌 Vol.31 No.5b
Mobile Ad-hoc Networks(MANETs)에서 정책기반 네트워크 관리를 위해서는 기존의 유선망 관리 방법으로는 신뢰성과 효율성을 보장 할 수 없다. 그러므로 MANETs 관리는 노드들을 효과적으로 클러스터하고 이동 관리를 하는 것이 필수적이다. 본 논문에서는 분산 되어 있는 PDP(Policy Decision Point)를 발견하는 Active PDP Discovery Protocol과 PEP(Policy Enforcement Point)노드 이동 감지를 위해 COPS-PR을 확장하고 PDP에 MNL(Management Node List)를 추가하여 PEP노드를 관리하는 방법을 제안한다. 그리고 시뮬레이션을 통해 얻은 결과를 분석하고 결론으로 끝맺는다. Policy-based Network Management(PBNM) in the Mobile Ad-hoc network(MANETs) requires additional, reliable and efficient mechanism over PBNM in wired network. Thus, it is important that the management system in MANETs should cluster the moving nodes and manage their movements in an effective manner. In this thesis, I propose a mechanism for the policy-based management in ad hoc networks in which I consider several methods to discover the Policy Decision Point(PDP), set the management area, and manage the movements of Policy Enforcement Point(PEP) nodes in the PBNM system. Moreover, COPS-PR is extended for the mechanism. Finally, I analyze and validate the results through simulations.
Nd<sub>2-x</sub>Sr<sub>x</sub>NiO<sub>4+</sub><sub>δ</sub>/GDC(x = 0, 0.4, 0.6) 공기극의 전기화학특성 평가
이경진,서정욱,임예솔,황해진,Lee, Kyoung-Jin,Seo, Jeong-Uk,Lim, Ye-Sol,Hwang, Hae-Jin 한국세라믹학회 2014 한국세라믹학회지 Vol.51 No.1
Mixed ionic and electronic conducting $K_2NiF_4$-type oxide, $Nd_{2-x}Sr_xNiO_{4+\delta}$ (x = 0, 0.4, 0.6) powders were synthesized by a solid-state reaction technique and solid oxide fuel cells consisting of a $Nd_{2-x}Sr_xNiO_{4+\delta}-GDC$ cathode, a Ni-YSZ anode and 8YSZ as an electrolyte were fabricated. The effect of strontium substitution for neodymium on the electrical and electrochemical properties was examined. The electrical conductivity increased with an increase in the Sr doping content, while it appears that the excess oxygen (${\delta}$) decreased. Sr doping into $Nd_2NiO_{4+\delta}$ resulted in an increase in the cathode polarization resistance and an decrease in the power density of the cell. These phenomena may be associated with the decreased amount of excess oxygen noted in the $Nd_{2-x}Sr_xNiO_{4+\delta}$ cathode.