        딸기재배 스마트 온실용 온습도 계측시스템의 성능평가

        정영균,이종구,안은기,서재석,김현태,윤용철 (사) 한국생물환경조절학회 2019 생물환경조절학회지 Vol.28 No.2

        This study compared the temperature and humidity measured by an aspirated radiation shield (ARS), the accuracy of which has been recently verified, and those measured by a system developed by the parent company (Company A) to investigate and improve the performance of the developed system. The results are as follows. Overall, the two-plate system had a lower radiation shielding effect than the one-plate system but showed better performance results when excluding the effect of strawberry vegetation on the systems. The overall maximum temperature ranges measured by company A’s system and the ARS were 20.5~53.3oC and 17.8~44.1oC, respectively. Thus, the maximum temperature measured by company A’s system was 2.7~9.2oC higher, and the maximum daily temperature difference was approximately 12.2oC. The overall average temperature measured by company A’s system and the ARS was 12.4~38.6oC and 11.8~32.7oC, respectively. Thus, the overall average temperature measured by company A’s system was 0.6~5.9oC higher, and the maximum daily temperature difference was approximately 6.7oC. The overall minimum temperature ranges measured by company A’s system and the ARS were 4.2~28.6oC and 2.9~26.4oC, respectively. Thus, the minimum temperature measured by company A’s system was 1.3~2.2oC higher, and the minimum daily temperature difference was approximately 2.9oC. In addition, the overall relative humidity ranges measured by company A’s system and the ARS were 52.9~93.3% and 55.3~96.5%, respectively. Thus, company A’s system showed a 2.4~3.2% lower relative humidity range than the ARS. However, there was a day when the relative humidity measured by company A’s system was 18.0% lower than that measured by the ARS at maximum. In conclusion, there were differences in the relative humidity measured by the two company’s devices, as in the temperature, although the differences were insignificant. 본 연구는 기존에 사용하여 왔고, 최근에 온습도의 정확도를 검증하였던 강제 흡출식 복사선 차폐장치(Aspirated Radiation Shield; ARS)와 모 기업(A 회사)에서 개발한 시스템으로 측정한 온습도를 비교하여 성능을검토한 후, 시스템의 성능을 개선할 목적으로 수행되었다. 그 결과를 요약하면 다음과 같다. 딸기의 무성도가두 계측시스템에 영향을 미친 경우를 제외하면, 전체적으로 볼 때 플레이트 2개의 시스템이 1개보다 복사선 차폐효과가 미미하지만 좋은 것으로 나타났다. 그리고 A회사의 시스템과 ARS장치로 측정한 최고온도의 전체적인 범위는 각각 20.5~53.3oC 및 17.8~44.1oC정도로써 A사 제품이 2.7~9.2oC정도 높게 나타났고, 일별 최대 편차는 12.2oC 정도였다. 평균온도의 경우, 두 기관의 전체적인 범위는 각각 12.4~38.6oC 및 11.8~32.7oC정도로써 A사 시스템이0.6~5.9oC정도 높게 나타났고, 일별 최대 편차는 6.7oC정도였다. 최저온도의 경우도 각각 4.2~28.6oC 및 2.9~26.4oC정도로써 A사 제품이 1.3~2.2oC정도 높게 나타났고, 일별 최대 편차는 2.9oC정도로써 두 기관의 장치로 측정한 온도에편차가 있는 것으로 나타났다. 또한 상대습도의 경우, A회사와 ARS장치로 측정한 평균상대습도의 전체적인 범위는각각 52.9~93.3% 및 55.3~96.5%정도로써 A회사의 시스템이 ARS장치보다 2.4~3.2%정도 낮게 나타나는 경향을 보였다. 그러나 일별로 비교하여 보면, 최대 18.0%정도 A회사의 시스템이 낮게 나타나는 날도 있었다. 결국 상대습도도 온도와 마찬가지로 미미하긴 하지만 두 기관의 장치로측정한 온도에 편차가 있는 것으로 나타났다.

      • KCI등재

        강제 흡출식 복사선 차폐장치가 온실의 기온측정에 미치는 영향

        정영균,이종구,윤성욱,김현태,안은기,서재석,윤용철 (사) 한국생물환경조절학회 2019 생물환경조절학회지 Vol.28 No.1

        This study was designed to examine the performance of an aspirated radiation shield(ARS), which was made at the investigator's lab and characterized by relatively easier making and lower costs based on survey data and reports on errors in its measurements of temperature and relative humidity. The findings were summarized as follows: the ARS and the Jinju weather station made measurements and recorded the range of maximum, average, and minimum temperature at 2.0~34.1oC, -6.1~22.2oC, –14.0~15.1oC and 0.4~31.5oC, -5.8~22.0oC, -14.1~16.3oC, respectively. There were no big differences in temperature measurements between the two institutions except that the lowest and highest point of maximum temperature was higher on the campus by 1.6oC and 2.6oC, respectively. The measurements of ARS were tested against those of a standard thermometer. The results show that the temperature measured by ARS was lower by –2.0oC or higher by 1.8oC than the temperature measured by a standard thermometer. The analysis results of its correlations with a standard thermometer reveal that the coefficient of determination was 0.99. Temperature was compared between fans and no fans, and the results show that maximum, average, and minimum temperature was higher overall with no fans by 0.5~7.6oC, 0.3~4.6oC and 0.5~3.9oC, respectively. The daily average relative humidity measurements were compared between ARS and the weather station of Jinju, and the results show that the measurements of ARS were a little bit higher than those of the Jinju weather station. The measurements on June 27, July 26 and 29, and August 20 were relatively higher by 5.7%, 5.2%, 9.1%, and 5.8%, respectively, but differences in the monthly average between the two institutions were trivial at 2.0~3.0%. Relative humidity was in the range of –3.98~+7.78% overall based on measurements with ARS and Assman's psychometer. The study analyzed correlations in relative humidity between the measurements of the Jinju weather station and those of Assman's psychometer and found high correlations between them with the coefficient of determination at 0.94 and 0.97, respectively. 본 연구에서는 본 연구실에서 자체적으로 제작한 비교적 제작이 간편하고 비용이 저렴한 강제 흡출식 복사선차폐장치(Aspirated Radiation Shield; ARS)로 측정한 실측 데이터를 바탕으로 장치의 성능과 온도 및 상대습도의 측정오차에 대하여 보고하고자 연구를 수행하였다. 그 결과를 요약하면 다음과 같다. ARS장치와 진주기상대에서 측정한 최대, 평균 및 최저온도의 범위는 각각2.0~34.1oC 및 0.4~31.5oC, -6.1~22.2oC 및 -5.8~22.0oC, -14.1~16.3oC 및 14.0~15.1oC범위로 나타났다. 최대기온의 최저 및 최고온도에서 각각 1.6oC 및 2.6oC정도 교내에서 측정한 값이 약간 높게 나타난 것을 제외하면, 두기관에서 측정한 온도에 큰 차이가 없는 것을 알 수 있었다. 표준온도계의 측정값과 검증한 결과, ARS장치로측정한 온도가 표준온도계에 비해 -2.0oC정도 낮거나1.8oC보다 높게 나타나났다. 표준온도계와 상관분석 한결과, 결정계수는 0.99정도였다. 팬의 유무에 따른 온도의 경우, 전체적으로 팬이 없는 경우가 최고, 평균 및최저온도가 각각 0.5~7.6oC, 0.3~4.6oC 및 0.5~3.9oC정도높게 나타났다. 그리고 ARS장치와 진주기상대에서 측정한 일평균 상대습도는 전체적으로 ARS장치로 측정한 값이 약간 높은 경향이 있고, 특히 상대적으로 6월 27일, 7 월 26일, 29일, 8월 20일에 측정한 값이 각각 5.7%, 5.2%, 9.1% 및 5.8%정도로 다소 높게 나타났지만, 두기관의 월별 평균치는 2.0~3.0%정도로 미미한 수준이었다. 또한 ARS장치와 아스만 통풍습도계로 측정한 상대습도는 전체적으로 -3.98~+7.78%정도의 범위 내에 있는것으로 나타났다. 진주기상대와 아스만 통풍습도계로 측정한 상대습도를 상관분석 결과, 결정계수가 각각 0.94 및 0.97정도로써 높은 상관관계를 보였다.

      • KCI등재

        딸기재배 온실용 온습도 계측시스템의 성능개선

        정영균(Young Kyun Jeong),이종구(Jong Goo Lee),안은기(Enu Ki Ahn),서재석(Jae Seok Seo),윤용철(Yong Cheol Yoon) (사)한국생물환경조절학회 2020 시설원예‧식물공장 Vol.29 No.2

        본 연구는 기존에 사용하여 왔고, 최근에 온습도의 정확도를 검증하였던 강제 흡출식 복사선 차폐장치(Aspirated Radiation Shield; ARS)를 이용하여 모 기업(A 회사)에서 개발한 시스템의 성능을 개선하고, ARS 장치의 풍속이 온습도에 미치는 영향에 대해서도 시험적으로 검토하였다. 그 결과를 요약하면 다음과 같다. A 회사 제품의 시스템을 개선하기 전, A 회사 시스템의 온도는 ARS 장치로 측정한 온도보다 최대 10.2℃정도 높았고, 상대습도는 20.0%정도 낮게 나타났다. 시스템을 개선한 후, 노드 1, 2의 온도 및 상대습도는 거의 일치하는 것으로 나타났다. 개선 후의 노드 2와 ARS 장치로 측정한 온도간의 최고, 평균 및 최저온도를 포함한 온도편차는 각각 0.2~0.7℃정도로써 ARS 장치가 약간 낮거나 높게 나타나는 경향이 있었다. 상대습도의 경우, 일몰 직후 ARS 장치의 상대습도가 약 10.0%정도 높게 나타나는 경향이 있었지만, 그 이외에는 평균적으로 1.9%정도 ARS 장치가 약간 낮게 나타나는 경향이 있었다. 그리고 노드 1을 최소-중간 사이, 중간-최대 사이 및 최대로 설정한 경우, 노드 1, 2의 최고, 평균 및 최저온도를 포함한 편차는 각각 0.1~0.4℃, 0.0~0.2℃ 및 0.0~0.5℃정도였다. 그리고 노드 1의 3개 측점과 ARS 장치의 최고, 평균 및 최저온도를 포함한 편차는 각각 0.2~0.5℃, 0.1~2.2℃ 및 0.1~1.1℃정도의 범위로써 풍속의 크기에 따른 온도편차는 아주 미미한 것으로 나타났다. 또한 선행연구 및 본 연구의 결과를 종합하여 보면, 온도오차를 개선하기 위한 적정 풍속은 1.0~2.0m·s<SUP>-1</SUP> 정도의 범위일 것으로 판단되었다. This study investigates the improvement in the performance of a temperature and humidity measuring system developed by Company A using the Aspirated Radiation Shield (ARS). The shield has been used in the industry and its accuracy was verified recently. The study also experimentally examines the impact of the wind speed of the ARS device on temperature and humidity. The results are summarized as follows. Before the improvement of the system, the temperature of Company A"s system was up to 10.2°C higher than that measured by the ARS device, and the measured relative humidity was approximately 20.0% lower. After improving the system, the temperature and relative humidity of nodes 1 and 2 were found to be almost identical. The temperature deviations including the maximum, mean, and minimum temperatures between those measured in node 2 and by ARS were approximately 0.2 to 0.7°C, respectively; further, the values measured by ARS tended to be slightly lower or higher. In terms of relative humidity, the ARS measurements yielded values approximately 10.0% higher immediately after sunset; otherwise, the values were approximately 1.9% lower. Moreover, when node 1 was set to minimum-middle, middle-maximum, and maximum, the deviations including the maximum, mean, and minimum temperatures of nodes 1 and 2 were 0.1 to 0.4°C, 0.0 to 0.2°C, and 0.0 to 0.5°C, respectively. The deviations including the maximum, average, and minimum temperatures of the three points of node 1 and the ARS ranged from 0.2 to 0.5°C, 0.1 to 2.2°C, and 0.1 to 1.1°C, respectively, indicating that the temperature deviation according to the wind speed was negligible. In addition, considering the results of the previous study with those from this study, the optimal wind speed to improve the temperature deviation is considered to be in the range of 1.0~2.0 m·s<SUP>-1</SUP>