http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
소정훈(J. H. So),정영석(Y. S. Jung),유병규(B. G. Yu),황혜미(H. M. Hwang),유권종(G. J. Yu),최주엽(J. Y. Choi) 전력전자학회 2006 전력전자학술대회 논문집 Vol.- No.-
This paper presents the performance results of 50㎾ grid-connected PV (Photovoltaic) system for monitoring periods. Form these performance monitoring results, the PV system performance has been evaluated and analyzed for component perspective (PV array and power conditioning unit) and global perspective (system efficiency, capacity factor, and electrical power energy and power quality etc.).
소정훈(J.H.So),유권종(G.J.Yu),정명웅(M.W.Jung),이종건(J.K.Lee),석줄기(J.K.Seok),최주엽(J.Y.Choi) 전력전자학회 2002 전력전자학술대회 논문집 Vol.- No.-
This paper compares the performances of estimate by computer simulation considering parameters of system specifications. installation and surrounding conditions with those of real PV system and show verification of designed value. We evaluate the performances of PV system with changing of parameter, specially a field type and suggest optimum condition in each field type.<br/> In the future, We will intend to develop an analysis tool and construct database for optimum design of PV system.
소정훈(J.H.So),정영석(Y.S.Jung),유권종(G.J.Yu),최주엽(J.Y.Choi) 전력전자학회 2003 전력전자학술대회 논문집 Vol.2003 No.11
3kW grid-connected photovoltaic(PV) systems and data acquisition system are constructed for performance analysis of PV system at field demonstration test center of Gwang- Ju in Korea. As climatic and irradiation conditions are varied, opera6on characteristics of the PV system are collected and analyzed in data acquisition system. From these results, the performances of PV systems have simulated and evaluated using simulation tool in comparison with actual value of data acquisition system of field demonstration test center. Furthermore, performance of each PV system e.g. electric power and loss factor is reviewed.
소정훈(J. H. So),정영석(Y. S. Jung),유병규(B. G. Yu),강기환(G. H. Kang),유권종(G. J. Yu),최주엽(J. Y. Choi) 전력전자학회 2005 전력전자학술대회 논문집 Vol.- No.-
This paper presents the performance results of roof-integrated 3kW PV (Photovoltaic) system by field testing. Form these results, the loss factors of PV system are compared and analyzed.
3kW급 계통연계형 태양광 발전시스템의 성능 비교 분석
소정훈(J.H. So),정영석(Y.S. Jung),유권종(G.J. Yu),이기옥(K.O. Lee),최주엽(J.Y. Choi),안현식(H.S. Ahn) 전력전자학회 2003 전력전자학술대회 논문집 Vol.2003 No.7(2)
3kW grid-connected photovoltaic (PV) system and data acquisition system are constructed for performance analysis of PV system at field demonstration test center of Gwang- Ju in Korea. As climatic and irradiation conditions are varied, operation characteristics of the PV system are collected and analyzed in data acquisition system. From these results, the performances of PV system have simulated and evaluated using simulation tool in comparison with actual value of data acquisition system of field demonstration test center. Furthermore, performance of total PV system ego electric power and loss factor at the site are reviewed.<br/>