RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재후보

        올메살탄 메독시밀 제제의 생물학적 동등성과용량 비례성에 관한 연구

        조성권,김춘옥,유수현,오은실,장성복,박융식,조경희,정재용 대한임상약리학회 2012 Translational and Clinical Pharmacology Vol.20 No.2

        Background: Olmesartan medoxomil is an angiotensin II receptor blocker commonly used in hypertension. First objective of this study was to evaluate the bioequivalence of two olmesartan formulations, Olmesartan 20 mg and 40 mg tablet (Yuhan, Pharmaceutical Corp. Seoul, Korea) as test drugs and Olmetec® 20 mg and 40 mg tablet (Daewoong, Pharmaceutical Corp. Seoul, Korea) as reference drugs. Second objective of this study was to evaluate the dose-proportionality of two formulations. Methods: Two studies (20 mg, 40 mg) were conducted as a randomized, open-label, 2-period, crossover design. Each subject received one 20 mg or 40 mg tablet of the reference or test formulation of olmesartan medoxomil in each study. Blood samples were obtained during the 48-hour period after the dose in each treatment period. Wash-out period was 1 week in each study. Concentrations of olmesartan medoxomil in plasma were analyzed using a liquid chromatography system with tandem mass-spectrometric detection (LC/MS/MS). The primary pharmacokinetic parameters were Cmax (maximum concentration) and AUCt (area under the concentration-time curve from time 0 to the last sampling time). Results: A total number of 40 healthy male volunteers participated in the study and 37 volunteers completed both treatment periods in 20 mg trial. All 40 participants completed both treatment periods in 40 mg trial. The 90 % CIs for the geometric mean ratios of the pharmacokinetic parameters (test:reference drug) were 0.93 ~ 1.04 for AUCt and 0.97 ~ 1.08 for Cmax in 20 mg trial. The 90 CIs were 0.94 ~ 1.02 for AUCt and 1.00 ~ 1.11 for Cmax in 40 mg trial. All parameters of two studies satisfy the range of bioequivalence criterion. Conclusion: The obtained results indicated that pharmacokinetic exposure to Olmesartan 20 mg and 40 mg tablet was bioequivalent to that of Olmetec® 20 mg and 40 mg tablet, respectively.

      • KCI등재

        올메살탄 메독시밀 제제의 생물학적 동등성과 용량 비례성에 관한 연구

        조성권,김춘옥,유수현,오은실,장성복,박융식,조경희,정재용,Cho, Sung Kweon,Kim, Choon Ok,Yu, Su Hyun,Oh, Eun Sil,Jang, Seong Bok,Park, Yoong Sik,Cho, Kyunghee,Chung, Jae-Yong 대한임상약리학회 2012 臨床藥理學會誌 Vol.20 No.2

        Background: Olmesartan medoxomil is an angiotensin II receptor blocker commonly used in hypertension. First objective of this study was to evaluate the bioequivalence of two olmesartan formulations, Olmesartan 20 mg and 40 mg tablet (Yuhan, Pharmaceutical Corp. Seoul, Korea) as test drugs and $Olmetec^{(R)}$ 20 mg and 40 mg tablet (Daewoong, Pharmaceutical Corp. Seoul, Korea) as reference drugs. Second objective of this study was to evaluate the dose-proportionality of two formulations. Methods: Two studies (20 mg, 40 mg) were conducted as a randomized, open-label, 2-period, crossover design. Each subject received one 20 mg or 40 mg tablet of the reference or test formulation of olmesartan medoxomil in each study. Blood samples were obtained during the 48-hour period after the dose in each treatment period. Wash-out period was 1 week in each study. Concentrations of olmesartan medoxomil in plasma were analyzed using a liquid chromatography system with tandem mass-spectrometric detection (LC/MS/MS). The primary pharmacokinetic parameters were $C_{max}$ (maximum concentration) and $AUC_t$ (area under the concentration-time curve from time 0 to the last sampling time). Results: A total number of 40 healthy male volunteers participated in the study and 37 volunteers completed both treatment periods in 20 mg trial. All 40 participants completed both treatment periods in 40 mg trial. The 90 % CIs for the geometric mean ratios of the pharmacokinetic parameters (test:reference drug) were 0.93 ~ 1.04 for $AUC_t$ and 0.97 ~ 1.08 for $C_{max}$ in 20 mg trial. The 90 CIs were 0.94 ~ 1.02 for $AUC_t$ and 1.00 ~ 1.11 for $C_{max}$ in 40 mg trial. All parameters of two studies satisfy the range of bioequivalence criterion. Conclusion: The obtained results indicated that pharmacokinetic exposure to Olmesartan 20 mg and 40 mg tablet was bioequivalent to that of $Olmetec^{(R)}$ 20 mg and 40 mg tablet, respectively.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼