http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
반맹에서 반시야 문양 시유발전위와 빛간섭단층촬영과의 일치성
박성용,박상혁,하승주,박성희,Sung Yong Park,Sang Hyouk Park,Seung Joo Ha,Song Hee Park 대한안과학회 2008 대한안과학회지 Vol.49 No.11
Purpose: To analyze the correlation between RNFL thickness changes measured by OCT and hemifield pattern VEP in hemianopic visual field loss. Methods: Twelve eyes of six patients with hemianopia were studied. Two patients had bitemporal hemianopia caused by chiasmal tumor, one patient had inferior hemianopia caused by traumatic optic neuropathy, and three patients had homonymous hemianopia caused by occipital lobe lesions. The retinal nerve fiber layer thickness around the optic disc was measured by optical coherence tomography (OCT) and visual pattern evoked potentials were measured using hemifield stimulations. Results: Normal eyes of traumatic optic neuropathy patients were excluded from the analysis. The retinal nerve fiber layer thickness as measured by OCT corresponded to the visual field defect in 9 of 11 eyes (81.8%) and the hemifield pattern VEP response corresponded to visual field defect in 7 of 11 eyes (63.6%). Conclusions: RNFL thickness measurement by OCT and hemifield PVEP are useful in evaluation of patients with hemianopia. However, they should be performed with caution, and compared with various clinical examinations because of their incomplete correlation with visual field defects. J Korean Ophthalmol Soc 2008;49(11):1819-1828
박성용,남부현,김정면,최기봉,연규석,김용성,Park, Sungyong,Nam, Boohyun,Kim, Jungmeyon,Choi, KiBong,Yeon, Kyuseok,Kim, Yongseong 한국농공학회 2016 한국농공학회논문집 Vol.58 No.6
This study is a basic research on the functional performance review for the use of environmentally friendly construction materials as lapilli-bio block. The neutralization processed Mt. Backdusan and Mt. Hallasan lapilli-bio block were identified vegetation characteristics and water purification properties. As a result, the adsorption of root was more favorable, depending on the material properties of many voids Lapilli. And if the neutralization processed lapilli-bio blocks maintain a long-term immersion conditions in contaminated water was found to be expected from the improvement effect of SS, T-N and T-P. However, field trials and continuous studies are expected to be identified by the use of lapilli-bio block.
지역난방 급탕공급 부하균등화를 위한 잠열축열조의 현장 적용
박성용,유호선,Park, Sung Yong,Yoo, Hoseon 한국플랜트학회 2021 플랜트 저널 Vol.17 No.2
지역난방의 운영적 측면에서 특정시간의 피크부하 완화를 통한 효율적인 열생산과 공급 및 지역난방 공급 중단 시 급탕 공급은 난방 대비 대체가 어려워 사용자 측면의 불편함과 공급자 측면의 애로사항을 해결할 수 있는 적용 기술이 요구되고 있다. 본 연구에서는 이러한 문제점을 해결할 수 있는 기술 중 열저장 능력과 급탕공급에 적합한 78℃급 수화물계 잠열축열조를 제작하여 지역난방 사용자 아파트 급탕공급설비에 현장 적용하였다. 본 시스템의 적용 결과 기존 공급방식 대비 급탕온도의 변화가 거의 없이 일정하게 사용자에게 공급됨을 확인하였으며, 피크 열부하는 평균 35% 감소와 비상열원으로서의 활용 가능성을 확인하였다. 또한 부하균등화에 따른 피크부하 감소로 기존 열 공급시설에서 10%의 열공급 여유와 신규 열공급시설 건설비용 및 열사용자의 공사비부담금이 각 5%와 10%가 감소됨을 확인하였다. In terms of district heating operation, efficient production and supply of heat by alleviating the peak load at a specific time require an application technology that can solve the inconvenience of the user and the difficulties of the supplier. In this study, a 78 ℃ class PCM heat storage tank suitable among the technologies that can solve these problems was manufactured and applied to the hot water supply facility for apartments in district heating users. As a result of the application of this system, it was confirmed that the supply temperature was constant to the user compared to the existing supply method. In addition, it was confirmed that the reduction of the peak load due to load equalization reduced the heat supply margin of 10% in the existing heat supply facility. And the construction cost of the new heat supply facility and the construction cost of heat users is decreased by 5% and 10%, respectively.
산화아연-탄소나노튜브 복합체의 일산화질소 가스 감지 특성
박성용,정훈철,안은성,웬래훙,강영진,김효진,김도진,Park, Seong-Yong,Jung, Hoon-Chul,Ahn, Eun-Seong,Nguyen, Le Hung,Kang, Youn-Jin,Kim, Hyo-Jin,Kim, Do-Jin 한국재료학회 2008 한국재료학회지 Vol.18 No.12
The NO gas sensing properties of ZnO-carbon nanotube (ZnO-CNT) composites fabricated by the coaxial coating of single-walled CNTs with ZnO were investigated using pulsed laser deposition. Upon examination, the morphology and crystallinity of the ZnO-CNT composites showed that CNTs were uniformly coated with polycrystalline ZnO with a grain size as small as 5-10 nm. Gas sensing measurements clearly indicated a remarkable enhancement of the sensitivity of ZnO-CNT composites for NO gas compared to that of ZnO films while maintaining the strong sensing stability of the composites, properties that CNT-based sensing materials do not have. The enhanced gas sensing properties of the ZnO-CNT composites are attributed to an increase in the surface adsorption area of the ZnO layer via the coating by CNTs of a high surface-to-volume ratio structure. These results suggest that the ZnO-CNT composite is a promising template for novel solid-state semiconducting gas sensors.
전립선암에 대한 초음파 영상유도 방사선치료의 Setup 오차 분석을 통한 재현성 평가
박성용,임승규,시명근,이지해,김종열,조은주,Park, Sung Yong,Lim, Seung Kyu,Si, Myoung Geun,Lee, Ji Hae,Kim, Jong Yeol,Cho, Eun Joo 대한방사선치료학회 2017 대한방사선치료학회지 Vol.29 No.2
목 적: 전립선암 환자에 대한 비침습적이고 피폭선량에 대한 부담이 없는 초음파를 이용한 영상유도방사선치료의 Setup 오차 분석을 통해 치료의 재현성을 평가해 보고자 한다. 대상 및 방법: 치료가 종료된 전립선암 환자 26명의 1,105영상에 대하여 앞-뒤(anterior-posterior, AP), 좌-우(right-left, RL), 위-아래(superior-inferior, SI) 방향의 Setup 오차에 대해 평균, 표준편차와 3D-error을 분석하였다. 또한 오차범위 0-1 mm, 1-3 mm, 3-5 mm, 5 mm 이상에 대한 각 오차 빈도수(frequency, %) 분석을 통하여 AP, RL, SI 방향에 대한 방향성을 확인 하였다. 결 과: Setup 오차는 AP, RL, SI 방향에 대하여 평균과 표준편차는 $1.87{\pm}1.36mm$, $1.73{\pm}1.22mm$, $2.01{\pm}1.40mm$였다. 3D-error는 평균 $3.63{\pm}1.63mm$였다. 각 방향에 대한 Setup 오차값의 빈도(frequency, %)는 AP 방향에 대한 오차범위 0-1 mm에서 29 %, 1-3 mm에서 50.2 %, 3-5 mm에서 19.6 %, 5 mm 이상에서 1.3 %였다. RL 방향에 대하여 오차범위 0-1 mm에서 31.3 %, 1-3 mm에서는 52.5 %, 3-5 mm에서는 15.8 %, 5 mm 이상에서 0.5 %였다. 마지막으로 SI 방향에 대한 오차범위 0-1 mm에서 26.3 %, 1-3 mm에서 50.2 %, 3-5 mm에서 22.4 %, 5 mm 이상에서 1.1 %였다. 결 론: Setup error는 SI 방향에서 $2.01{\pm}1.40mm$로 가장 컸으며 오차 빈도는 모든 방향에서 50 % 이상 오차 범위 1-3 mm에 들어온 것으로 확인되었다. $Clarity^{TM}$ Auto scan을 이용한 초음파영상유도 방사선치료는 치료 전에 방광의 전처치 상태, target의 구조 등을 관찰이 가능하고, 치료 중 target의 움직임을 실시간으로 monitoring하여 빠른 repositioning이 가능하다. 결과적으로 초음파를 이용한 실시간 영상유도방사선치료는 치료의 재현성을 높일 수 있을 것으로 사료된다. Purpose: To evaluate the reproducibility of image-guided radiotherapy using ultrasonography which is non-invasive, without radiation exposure for prostate cancer patients. Materials and Methods: We analyzed the setup variation of 1,105 images for 26 prostate cancer patients and the mean, standard deviation and 3D-error in AP, RL and SI directions. Setup variations were classified 0-1 mm, 1-3 mm, 3-5 mm, 5 mm and more. Results: The mean and standard deviation of setup variation in AP, RL and SI directions was $1.87{\pm}1.36mm$, $1.73{\pm}1.22mm$ and $2.01{\pm}1.40mm$. The 3D-error in AP, RL and SI directions was $3.63{\pm}1.63mm$. The frequency of setup variation in AP direction was 29 % in the range from 0 mm to 1 mm, 50.2 % in the range from 1 mm to 3 mm, 19.6 % in the range from 3 mm to 5 mm and 1.3 % in the range of 5 mm or more. In RL direction, the frequency was 31.3 % in the range from 0 mm to 1 mm, 52.5 % in the range from 1 mm to 3 mm, 15.8 % in the range from 3 mm to 5 mm and 0.5 % in the range of 5 mm or more. SI direction, the frequency of errors in the range from 0 mm to 1 mm was 26.3 %, 50.2 % in the range from 1 mm to 3 mm, 22.4 % in the range from 3 mm to 5 mm, and 1.1 % in the range of 5 mm or more. Conclusion: The setup error was highest in the SI direction of $2.01{\pm}1.40mm$. The frequency in each direction was the highest in more than 50 % in the range from 1 mm to 3 mm. $Clarity^{TM}$ Auto scan is possible to monitoring the motion of the prostate during the treatment and to repositioning the patient. In conclusion real-time image-guided radiotherapy using ultrasonography will be increase the reproducibility of radiation therapy.