To investigate the characteristics of the merged jet arising from the interaction of two opposing curved wall jets over a circular cylinder in still air, mean velocity, Reynolds stresses, triple moments and integral length scale were measured using hot-wire anenometry. The turbulent kinetic energy and shear stress budget were evaluated using the measured data. The variations of the Reynolds stresses, the triple moment and integral length scale are severe in the interaction region. The pressure diffusion terms are found to be very large when compared the other terms in the interaction region. The distributions of the Reynolds stress and the triple moment in the similar region are found to be similar to those of conventional plane jets.
2MW M/G 시스템을 이용한 가스터빈 정지형 기동장치 성능시험
류호선,이경규,문주영,이주현 대한전기학회 2020 전기학회논문지 P Vol.69 No.1
The purpose of the static starting equipment(SSE) is to accelerate a synchronous machine up to a speed at which it can begin to run on its own. Because of its compressor, gas turbine must be run up to about 20 30% of its rated speed before it is capable ∼ itself of producing enough power to continue accelerating the set. Recent korea researchers have developed the 10MW startup equipment based on the accumulated high power conversion technology. The 10MW startup equipment, which is scheduled to be applied to the B power plant, is equipped with the latest sensorless speed control technology. It was tested for checking performance before applying to the site. In this paper, the contents of the performance test were described. The performance test for 10MW startup equipment was carried out in two stages. The first stage of the test was performed without being linked with synchronous machine. The purpose of the test was to verify the developed hardware, basic control loop etc. In case of power conversion, the current control function was tested by shorting the converter. The two-stage test was carried out on a simulated environment using 2MW M/G system test facility. Basically, the test is for all function check of starting equipment. By estimated position and speed, It accelerated rotor until rated speed. Various performance evaluation results came out from the last tests before the field application. The performance of each control mode was satisfactory and the applied technology is expected to be well used for starting equipment.