http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
간접냉각방식을 이용한 열원이 부착된 채널내의 열전달 촉진에 관한 연구
김광추,박만흥,윤준규 대한설비공학회 1999 설비공학 논문집 Vol.11 No.3
A numerical study is carried out for increasing heat removal using indirect cooling system. Computation is performed for nine cases as variation of flow condition in the lower channel. As the result of this study, water is more effective than air at the same pressure loss in spite of the lower inlet velocity. In channel configuration, the vertical channel is more effective than horizontal channel because of the buoyancy effect. Under the condition that heat generation is the same, counter flow effectively decreases the temperature difference among blocks. Parallel flow is more effective than counter flow when average temperature of all blocks is considered. In the case of installing obstacles in the lower channel, it is desirable to install obstacles in the bottom of lower channel. Heat transfer rate increases as the height of obstacles increases.
김광추,임종한,윤준규 대한기계학회 2008 JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY Vol.22 No.11
The scheme and procedure for thermal fatigue estimation of a thermally stratified branch line were developed. Oneway FSI (fluid and structure interaction) scheme was applied to evaluate the thermal stratification piping. Thermal flow analysis, stress analysis and fatigue estimation were performed in serial order. Finally, detailed monitoring locations and mitigation scheme for the integrity maintenance of piping were recommended. All wall mesh and transient temperature distribution data obtained from the CFD (computational fluid dynamics) analysis were directly imported into the input data of stress analysis model without any calculation for heat transfer coefficients. Cumulated usage factors for fatigue effect review with nodes were calculated. A modified method that combines ASME Section III, NB-3600 with NB-3200 was used because the previous method cannot consider the thermal stratification stress intensity. As the results of evaluation, the SCS (shutdown cooling system) line, branch piping of the RCS (reactor coolant system) line, shows that the CUF (cumulative usage factor) value exceeds 1.0, ASME Code limit, in case thermal stratification load is included. The HPSI (high pressure safety injection) line, re-branch piping, shows that temperature difference between top and bottom of piping exceeds the criterion temperature, 28℃, and that the CUF value exceeds 1.0. Therefore, these branch pipings require a detailed review, monitoring or analysis. In particular, it is recommended that the HPSI piping should be shifted backward to decrease the influence of turbulent penetration intensity from the RCS piping.
원자로배수탱크내 Sparger에 대한 유동특성 및 최적설계
김광추,박만홍,박경식,이종원,Kim, Kwang-Chu,Park, Man-Heung,Park, Kyoung-Suk,Lee, Jong-Won 대한기계학회 1999 大韓機械學會論文集B Vol.23 No.11
A numerical analysis for ROT sparger of PWR(Pressurized Water Reactor) is carried out. Computation is performed to investigate the flow characteristics as the change of design factor. As the result of this study, RDT sparger's flow resistance coefficient is K=3.53 at the present design condition if engineering mar&in is considered with 20%, and flow ratio into branch pipe is $Q_s/Q_i=0.41$. Velocity distribution at exit is not uniform because of separation in branch pipe. In the change of inlet flow rate and section area ratio of branch pipe for main pipe, flow resistance coefficient is increased as $Q_s/Q_i$ decreasing, but in the change of branch angle and outlet nozzle diameter of main pipe, flow resistance coefficient is decreased as $Q_s/Q_i$ decreasing. As the change rate of $Q_s/Q_i$ is the larger, the change rate of flow resistance coefficient is the larger. The change rate of pressure loss is the largest change as section area ratio changing. The optimal design condition of sparger is estimated as the outlet nozzle diameter ratio of main pipe is $D_s/D_i=0.333$, the section area ratio is $A_s/A_i=0.2$ and the branch angle is ${\alpha}=55^{\circ}$.