http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
제동시간이 통풍형 디스크 브레이크 시스템의 건전성에 미치는 영향
곽우경,홍창기,김윤제,Gwak, Woo-Gyeong,Hong, Chang-Ki,Kim, Youn-Jea 한국자동차안전학회 2016 자동차안전학회지 Vol.8 No.1
In order to analyze the soundness of ventilated disc brake systems, numerical study was performed with various vane shapes. In particular, two different vane type, and the braking time from 3.0 s to 4.5s with the interval of 0.5s were considered. Transient temperature distributions on the ventilated disc brake assembly were calculated using ANSYS CFX ver. 16.1. To elucidate the soundness of ventilated disc brake systems, moreover, the heat transfer coefficients were evaluated. Results were graphically depicted with different geometrical vane configurations and braking time.
그루브 디스크 형상 변화가 통풍형 브레이크 시스템 성능에 미치는 영향
곽우경(Woo-Gyeong Gwak),김윤제(Youn-Jea Kim) 대한기계학회 2016 대한기계학회 춘추학술대회 Vol.2016 No.12
In this study, the heat transfer characteristics of the ventilated brake rotor system was numerically analyzed with various grooved disk configurations. In particular, different types of grooved disk which were straight groove, straight and curvature groove and circular groove were considered under transient condition. Since the heat of disk surface was generated by the contact between disk and pads, transient analysis is essential for the prediction of surface temperature and thus, transient temperature distributions on the ventilated brake rotor was investigated using the commercial CFD code ANSYS CFX ver. 17.1. The results of the temperature distribution and heat transfer coefficient were graphically depicted and compared for various grooved disk configurations to evaluate the heat transfer performance and find the best configuration.
흰쥐의 삼차신경주감각핵에서 치수유래 일차들신경종말 및 이와 연접하는 연접이전신경종말의 연접소포 형태 비교
김윤숙,백상규,곽우경,조이슬,김지만,박매자,배용철 韓國電子顯微鏡學會 2008 Applied microscopy Vol.38 No.4
삼차신경주감각핵에서 치수유래 일차들신경섬유의 종말과 그에 연접하는 연접이전신경종말에 함유된 연접소포들을 형태학적으로 비교하기 위하여 신경추적자(WGA-HRP)를 흰쥐 앞니의 치수강에 주입하여 치수 유래 일차들신경종말을 표식한 후, 투과형 전자현미경을 통한 미세구조적 정량 분석을 실시하였다. 표식된 치수유래 일차들신경종말은 직경이 45~55 nm인 구형의 소포를 함유하고 있었으며, 일부 직경이 80~120 nm인 큰 치밀소포가 관찰되기도 하였다. 또한 표식된 신경종말은 다형성 연접소포를 함유하고 있는 연접이전신경종말과 대칭연접을 이루고 있었다. 일차들신경종말의 연접소포들은 긴 지름에 대한 짧은 지름의 비율(form factor)이 0.6~0.99의 분포를 보인 반면, 연접이 전신경종말의 연접소포들은 0.25~0.99까지 다양하게 나타났다. 또한 대부분의 연접이전신경종말은 GABA에 대한 면역양성반응을 보였다. 이상의 결과는 표식된 신경종말과 그에 연접하는 연접이전신경종말의 연접소포는 서로 다른 형태를 보이고 있으며, 또한 그 연접이전신경종말이 억제성 신경전달물질인 GABA를 함유하고 있음을 나타낸다. In order to investigate shape of synaptic vesicles of the tooth pulp afferent boutons and their presynaptic endings (pendings), and the neuroactive substance of the p-endings in the trigeminal nucleus principalis, rat incisor tooth pulp afferents were labeled by the horseradish peroxidase (HRP) and quantitative ultrastructural analysis and postembedding immunogold labeling were performed. Labeled tooth pulp afferent boutons contained clear, spherical synaptic vesicles (diameter: 45~55 nm) and occasionally dense core vesicles(diameter: 80~120 nm). They formed symmetrical synapses with unlabeled axon terminals (p-endings) containing pleomorphic synaptic vesicles. The ratio of short to long diameter (form factor) of synaptic vesicles of pulp afferent boutons was 0.6 to 0.99, whereas that of p-endings was 0.25 to 0.99. In addition, most of the pendings showed GABA-like immunoreactivity. These results indicate that the shape of synaptic vesicles is quite different between the tooth pulp afferent boutons and p-endings, and the p-endings may contain GABA as a neuroactive substance in the trigeminal nucleus principalis.
족관절 삼과 골절에서 후과 골편 크기 측정을 위한 측면 단순 방사선 영상과 3차원 컴퓨터 단층촬영의 비교
이건우,정동민,곽우경,이근배 대한골절학회 2022 대한골절학회지 Vol.35 No.3
목적: 족관절 삼과 골절에서 측면 단순 방사선 사진과 3차원컴퓨터 단층촬영을 이용한 후과 골편의 크기 측정의 정확도를 비교하고자 시행되었다. 대상 및 방법: 총 80명(80예)의 족관절 삼과 골절 환자를 분석하였으며, 후과 골편의 크기 측정은 측면 단순 방사선 사진과 3D-CT를 이용하여 시행되었다. 후과 골편의 관절면 침범정도는 측면 단순 방사선 사진에서는 경골 천장부의 시상면길이에 대한 비율로 측정하였고, 3D-CT 영상에서는 경골천장부 면적에 대한 후과 골편 면적의 비율로 측정되었다. 그리고 후과 골절을 Haraguchi 분류법에 의해 세 군으로 분류하고 각 군에 따른 두 측정법의 정확도 차이를 비교하였다. 결과: 측면 단순 방사선 사진을 통한 후과 골편의 평균 관절면 침범 정도는 전체 경골 천장 면적의 27.6% (범위6.0%-53.1%)로 3D-CT를 이용하여 측정한 평균 크기인21.9% (범위 4.7%-47.1%)보다 유의하게 크게 측정되었다(p=0.004). 후과 골절 형태에 따른 분석에서 두 측정법의 평균 차이는 type I 골절에서 평균 9.1%로 가장 컸고, type II 골절에서 평균 1.1%로 가장 작았다. 결론: 측면 단순 방사선 사진을 통한 후과 골편의 평균 관절면 침범 정도는 실제 관절면 침범 정도에 비해 유의하게 큰 측정값을 보여 낮은 정확도를 보여주었다. 따라서 족관절 삼과골절에서 후과 골편의 크기를 정확하게 측정하기 위해서는3D-CT를 이용하여야 한다.
이정민(Jeong-min Lee),김진형(Jin-hyoung Kim),곽우경(Woo-gyeong Kwak),강민성(Min-sung Kang),김현신(Hyun-sin Kim),김윤제(Youn-Jea Kim) 대한기계학회 2015 대한기계학회 춘추학술대회 Vol.2015 No.11
Mass flow amplifier, which is an aerodynamic device, utilizes the Coandă effect. In this study, design optimization of mass flow amplifier was conducted by using three-dimensional Navier-Stokes analysis and the response surface method (RSM) with various configurations of Coandă nozzle. A numerical analysis was performed using the commercial code, ANSYS CFX with the shear stress transport (SST) turbulent model. Each of design parameters was sorted into three levels. Design parameters, which have 15 design points respectively, were planned using central composite design (CCD) method. Response surfaces, which were based on the results of DOE, were used to determine the optimal shape of Coandă nozzle. Through the optimization, aerodynamic performance of mass flow amplifier was improved.