http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
韓國産 各地方「집파리」(Musca domestica L.) 의 殺蟲劑에對한 抵抗性
金承斗,具燾書 中央醫學社 1962 中央醫學 Vol.2 No.1
It is a well known fact that the development of insecticide resistance by houseflies is of worldwide occurrence. As to the resistance problem of Korean houseflies, Wheeler et al. first reported in 1956 that the flies of the Seoul district were less tolerant to insecticides than of Japan, where flies showed a high degree of tolerance. In the following year, Pack observed that DDT resistance of houseflies in Seoul city was, about the same as Standard Strain at the Orlando Laboratory, USA. Since: then complaints occasionally have been made by the field sanitarians of large cities about the unsatisfactory results of insecticide spraying, but no such complaints have been heard from rural towns. Although the countrywide campaigns for insect control have been continuous for the past 15 years, it is probable that the urban areas have had more DDT-spraying than in the rural districts. This fact may contribute to the diversity of insecticide tolerance of houseflies between large cities and rural towns or villages. This study therefore was undertaken to find how much insecticide susceptibility differs among housefly populations of different regions. Common houseflies were collected from five different localities, viz., Seoul, Yungi, Yungdong,Yungchon, and Chunhan, and bred in the laboratory for five generations. Three kind of insecticides, p, p'-DDT, malathion and dieldrin were topically applied to the flies. For this, a Trevan's microsyringe was used by dropping each given amount of toxicant to the dorsum of individual flies. The test concentrations represented by microgram unit(ug) of each toxicant prepared through serial dilution with acetone were as follows p, PI-DDT…120, 60, 30. 15 Malathion…3, 1.5, 0.6, 0.3 Dieldrin…6, 3, 0.6, 0.3 Each test ran with 40 flies. Following the test, the flies placed in a 400 ML glass beaker covered with double layers of gauze and observed for their 24 hour's knockdown effects. At the same time control groups were treated with 6 x 10-5cc of acetone only. Mortalities of test flies were calculated by Bliss Probit method.
산화 그래핀을 이용한 구리이온 흡착과 투과도 특성을 이용한 구리이온 농도 실시간 측정
김승두,류희중,오훈정,황완식,Kim, Seungdu,Ryou, Heejoong,Oh, Hoon-Jung,Hwang, Wan Sik 한국반도체디스플레이기술학회 2021 반도체디스플레이기술학회지 Vol.20 No.2
Various Cu ions are discharged into water from various industries, which results in a severe trouble for groundwater, soil, air, and eventually animals and humans. In this work, graphene oxide (GO) is introduced as a Cu removal absorber and the real-time monitoring method is demonstrated. The results show that GO is a very effective material to absorb Cu ions in the solution. In addition, the residual Cu ions in the solution is monitored via optical transmittance method, which well match with Inductively Coupled Plasma Mass Spectrometer (ICP-MS) analysis.