RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • Microbiological Quality of Alternative Water Sources in the Urban Environment

        ( J. P. S. Sidhu ),( W. Ahmed ),( L. Hodgers ),( K. Smith ),( S. Toze ) 한국물환경학회 2017 한국물환경학회·대한상하수도학회 공동 춘계학술발표회 Vol.2017 No.-

        In Australia, decreasing rainfall, frequent drought and population growth in urban environments, along with an overall desire to achieve greater water sustainability, has increased the demand for alternative water sources such as stormwater, roof-harvested rainwater, and treated wastewater effluent. The potential public health risks associated with alternative water sources predominantly originate from the presence of enteric viruses, pathogenic bacteria, and protozoan parasites. Empirical data on the presence of pathogens is a prerequisite to accurately determine human health risks and the extent of treatment required prior to use for potable and nonpotable purposes. We have carried out a number of targeted studies on the microbiological quality of the roof-harvested rainwater, stormwater, and treated wastewater effluent in the Southeast Queensland (Australia). The main of aim these studies was to collect quantitative data on the presence of pathogens and make an assessment of the potential health risk associated with water reuse. A dedicated survey of the roof-harvested rainwater tanks in Brisbane has shown the presence of Campylobacter spp. (21%), Salmonella spp., (4%), and Giardia lamblia (13%). In addition, opportunistic pathogens Legionella spp. (99%) and Mycobacterium intracellulare (78%) were also detected\. The numbers of bacteria ranged up to 3.1 x 10<sup>6</sup> PCR detectable units (pdu) L<sup>-1</sup> for Legionella spp., 9.6 X 10<sup>5</sup> pdu L<sup>-1</sup> for P. aeruginosa, 6.8 X 10<sup>5</sup> pdu L<sup>-1</sup> for M. intracellulare, 6.6 x 10<sup>5</sup> pdu L<sup>-1</sup> for Acanthamoeba spp., 1.1 x 10<sup>5</sup> pdu L<sup>-1</sup> for M. avium, and 9.8 X 10<sup>3</sup> pdu L<sup>-1</sup> for L. pneumophila. The presence of potential opportunistic pathogens in tank water may present health risks if un-treated water is for potable and non-potable use in the house. Stormwater runoff from two urban catchments with different drainage area, impervious area, and land use, a potential source of pollution and population density was collected and analyzed for the presence of pathogens and fecal indicator bacteria. The mean FIB numbers in water samples collected after the storm event ranged from 10 <sup>3</sup> to 10<sup>4</sup> L<sup>-1</sup> for E. coli and 10 <sup>4</sup> to 10<sup>5</sup> L<sup>-1</sup> for Enterococcus spp. Salmonella enterica numbers varied between 10 to 2400 MPN L<sup>-1</sup>. Human adenovirus (HAdV) numbers in the stormwater varied between 10 to 10<sup>3</sup> pdu L<sup>-1</sup>, human polyomavirus (HPyV) numbers varied between 1 to 10<sup>3</sup> pdu L<sup>-1</sup>. Torque teno virus (HTtV) numbers varied between 10 to 7.45 x 10<sup>3</sup> pdu L<sup>-1</sup>. Somatic coliphages (Microviridae) was also widely prevalent with numbers varying between 10 to 10<sup>3</sup> pdu L<sup>-1</sup>. The results of this study suggest that enteric virus and bacterial pathogens frequently occur in the stormwater runoff in significant numbers which could lead to increased human health risks. A quantitative survey HAdV, HPyV, HTtV and somatic coliphage (Microviridae) numbers in influent and effluent samples was carried out from three wastewater treatment plants (WWTP) employing an activated sludge process to produce secondary treated effluent in Brisbane. HPyV, HAdV, HTtV and Microviridae were consistently detected in the primary influent in high numbers (10<sup>5</sup> to 10<sup>6</sup> pdu L<sup>-1</sup>) and secondary treated effluent (10<sup>2</sup> to 10<sup>3</sup> pdu L<sup>-1</sup>) across all three treatment plants. Under appropriate conditions, WWTPs with activated sludge process could be an effective treatment barrier with > 3 log10 removal of enteric. The results confirm the occurrence of enteric viruses in significant numbers in secondary treated effluent, tertiary treatment may be required prior to effluent reuse or discharged into the environmental to prevent exposure of people to health hazards.

      • SCIESCOPUSKCI등재

        An Iterative Technique for Real-Time Tracking of Power System Harmonics

        Sidhu, T.S.,Zadeh, M.R.D.,Pooranalingam, P.J.,Oh, Yong-Taek The Korean Institute of Electrical Engineers 2011 Journal of Electrical Engineering & Technology Vol.6 No.3

        An iterative technique based on orthogonal filters and frequency tracking is proposed to estimate harmonic components in power systems. The technique uses frequency interpolation to estimate fundamental frequency and harmonics when the nominal frequency of the signal is a non-integer value. Due to the number of computations involved during the generation of filter coefficients, an offline computation is suggested. Beneficial features of the proposed technique include fixed sampling rate and fixed data window size. The performance of the proposed technique is examined by simulating different power system operating conditions and evaluating the data from these simulations. A technique based on Fast Fourier Transform is also used to estimate the harmonic components for all the simulated signals. These estimates are compared with those obtained from the proposed technique. Results show that the proposed technique can converge to the accurate fundamental frequency and therefore, provide accurate harmonic components even when the fundamental frequency is not equal to the nominal frequency.

      • KCI등재

        An Iterative Technique for Real-Time Tracking of Power System Harmonics

        T. S. Sidhu,M. R. D. Zadeh,P. J. Pooranalingam,Yong-Taek OH 대한전기학회 2011 Journal of Electrical Engineering & Technology Vol.6 No.3

        An iterative technique based on orthogonal filters and frequency tracking is proposed to estimate harmonic components in power systems. The technique uses frequency interpolation to estimate fundamental frequency and harmonics when the nominal frequency of the signal is a non-integer value. Due to the number of computations involved during the generation of filter coefficients, an offline computation is suggested. Beneficial features of the proposed technique include fixed sampling rate and fixed data window size. The performance of the proposed technique is examined by simulating different power system operating conditions and evaluating the data from these simulations. A technique based on Fast Fourier Transform is also used to estimate the harmonic components for all the simulated signals. These estimates are compared with those obtained from the proposed technique. Results show that the proposed technique can converge to the accurate fundamental frequency and therefore, provide accurate harmonic components even when the fundamental frequency is not equal to the nominal frequency.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼