Removal of iron from drinking water by electrocoagulation: Adsorption and kinetics studies
Subramanyan Vasudevan,Jeganathan Jayaraj,Jothinathan Lakshmi,Ganapathy Sozhan 한국화학공학회 2009 Korean Journal of Chemical Engineering Vol.26 No.4
The present study provides an electrocoagulation process for the removal of iron from drinking water with aluminum alloy as the anode and stainless steel as the cathode. The studies were carried out as a function of pH, temperature and current density. The adsorption capacity was evaluated with both the Langmuir and the Freundlich isotherm models. The results showed that the maximum removal efficiency of 98.8% was achieved at a current density of 0.06 A dm−2, at a pH of 6.5. The adsorption of iron preferably fitting the Langmuir adsorption isotherm suggests monolayer coverage of adsorbed molecules. The adsorption process follows second-order kinetics. Temperature studies showed that adsorption was endothermic and spontaneous in nature.