RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • Trend estimates of AERONET-observed and model-simulated AOTs between 1993 and 2013

        Yoon, J.,Pozzer, A.,Chang, D.Y.,Lelieveld, J.,Kim, J.,Kim, M.,Lee, Y.G.,Koo, J.H.,Lee, J.,Moon, K.J. Pergamon Press ; Elsevier [distribution] 2016 Atmospheric environment Vol.125 No.1

        <P>Recently, temporal changes in Aerosol Optical Thickness (AOT) have been investigated based on model simulations, satellite and ground-based observations. Most AOT trend studies used monthly or annual arithmetic means that discard details of the generally right-skewed AOT distributions. Potentially, such results can be biased by extreme values (including outliers). This study additionally uses percentiles (i.e., the lowest 5%, 25%, 50%, 75% and 95% of the monthly cumulative distributions fitted to Aerosol Robotic Network (AERONET)-observed and ECHAM/MESSy Atmospheric Chemistry (EMAC)-model simulated AOTs) that are less affected by outliers caused by measurement error, cloud contamination and occasional extreme aerosol events. Since the limited statistical representativeness of monthly percentiles and means can lead to bias, this study adopts the number of observations as a weighting factor, which improves the statistical robustness of trend estimates. By analyzing the aerosol composition of AERONET-observed and EMAC-simulated AOTs in selected regions of interest, we distinguish the dominant aerosol types and investigate the causes of regional AOT trends. The simulated and observed trends are generally consistent with a high correlation coefficient (R = 0.89) and small bias (slope +/- 2 sigma = 0.75 +/- 0.19). A significant decrease in EMAC-decomposed AOTs by water-soluble compounds and black carbon is found over the USA and the EU due to environmental regulation. In particular, a clear reversal in the AERONET AOT trend percentiles is found over the USA, probably related to the AOT diurnal cycle and the frequency of wildfires. In most of the selected regions of interest, EMAC-simulated trends are mainly attributed to the significant changes of the dominant aerosols; e.g., significant decrease in sea salt and water soluble compounds over Central America, increase in dust over Northern Africa and Middle East, and decrease in black carbon and organic carbon over Australia. (C) 2015 The Authors. Published by Elsevier Ltd.</P>

      • SCIESCOPUSKCI등재

        Bacterial adhesion and colonization differences between zirconia and titanium implant abutments: an in vivo human study

        De Oliveira, Greison Rabelo,Pozzer, Leandro,Cavalieri-Pereira, Lucas,De Moraes, Paulo Hemerson,Olate, Sergio,De Albergaria Barbosa, Jose Ricardo Korean Academy of Periodontology 2012 Journal of Periodontal & Implant Science Vol.42 No.6

        Purpose: Several parameters have been described for determining the success or failure of dental implants. The surface properties of transgingival implant components have had a great impact on the long-term success of dental implants. The purpose of this study was to compare the tendency of two periodontal pathogens to adhere to and colonize zirconia abutments and titanium alloys both in hard surfaces and soft tissues. Methods: Twelve patients participated in this study. Three months after implant placement, the abutments were connected. Five weeks following the abutment connections, the abutments were removed, probing depth measurements were recorded, and gingival biopsies were performed. The abutments and gingival biopsies taken from the buccal gingiva were analyzed using real-time polymerase chain reaction to compare the DNA copy numbers of Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, and total bacteria. The surface free energy of the abutments was calculated using the sessile water drop method before replacement. Data analyses used the Mann Whitney U-test, and P-values below 0.05 find statistical significance. Results: The present study showed no statistically significant differences between the DNA copy numbers of A. actinomycetemcomitans, P. gingivalis, and total bacteria for both the titanium and zirconia abutments and the biopsies taken from their buccal gingiva. The differences between the free surface energy of the abutments had no influence on the microbiological findings. Conclusions: Zirconia surfaces have comparable properties to titanium alloy surfaces and may be suitable and safe materials for the long-term success of dental implants.

      • SCIESCOPUSKCI등재
      • KCI등재

        Bacterial adhesion and colonization differences between zirconia and titanium implant abutments: an in vivo human study

        Greison Rabelo de Oliveira,Leandro Pozzer,Lucas Cavalieri-Pereira,Paulo Hemerson de Moraes,Sergio Olate,Jose Ricardo de Albergaría Barbosa 대한치주과학회 2012 Journal of Periodontal & Implant Science Vol.42 No.6

        Purpose: Several parameters have been described for determining the success or failure of dental implants. The surface properties of transgingival implant components have had a great impact on the long-term success of dental implants. The purpose of this study was to compare the tendency of two periodontal pathogens to adhere to and colonize zirconia abutments and titanium alloys both in hard surfaces and soft tissues. Methods: Twelve patients participated in this study. Three months after implant placement, the abutments were connected. Five weeks following the abutment connections, the abutments were removed, probing depth measurements were recorded,and gingival biopsies were performed. The abutments and gingival biopsies taken from the buccal gingiva were analyzed using real-time polymerase chain reaction to compare the DNA copy numbers of Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, and total bacteria. The surface free energy of the abutments was calculated using the sessile water drop method before replacement. Data analyses used the Mann Whitney U-test, and P-values below 0.05 find statistical significance. Results: The present study showed no statistically significant differences between the DNA copy numbers of A. actinomycetemcomitans,P. gingivalis, and total bacteria for both the titanium and zirconia abutments and the biopsies taken from their buccal gingiva. The differences between the free surface energy of the abutments had no influence on the microbiological findings. Conclusions: Zirconia surfaces have comparable properties to titanium alloy surfaces and may be suitable and safe materials for the long-term success of dental implants.

      • KCI등재

        An in vitro comparison between two different designs of sagittal split ramus osteotomy

        Valdir Cabral Andrade,Leonardo Flores Luthi,Fabio Loureiro Sato,Leandro Pozzer,Sergio Olate,Jose Ricardo Albergaria-Barbosa 대한구강악안면외과학회 2015 대한구강악안면외과학회지 Vol.41 No.3

        Objectives: To evaluate the influence of the type of osteotomy in the inferior aspect of the mandible on the mechanical performance. Materials and Methods: The study was performed on 20 polyurethane hemimandibles. A sagittal split ramus osteotomy (SSRO) was designed in 10 hemimandibles (group 1) with a vertical osteotomy in the buccal side (second molar level) and final osteotomy was performed horizontally on the lingual aspect, while the mandible body osteotomy was finalized as a straight osteotomy in the basilar area, perpendicular to the body. For group 2, the same osteotomy technique was used, but an oblique osteotomy was done in the basilar aspect of the mandibular body, forming continuity with the sagittal cut in the basilar area. Using a surgical guide, osteosynthesis was performed with bicortical screws using an inverted L scheme. In both groups vertical compression tests were performed with a linear load of 1 mm/min on the central fossa of the first molar and tests were done with models made from photoelastic resin. Data were analyzed using Student’s t-test, establishing a statistical significance when P<0.05. Results: A statistical difference was not observed in the maximum displacements obtained in the two osteotomies (P<0.05). In the extensiometric analysis, statistically significant differences were identified only in the middle screw of the fixation. The photoelastic resin models showed force dissipation towards the inferior aspect of the mandible in both SSRO models. Conclusion: We found that osteotomy of the inferior aspect did not influence the mechanical performance for osteosynthesis with an inverted L system

      • Aerosol physicochemical effects on CCN activation simulated with the chemistry-climate model EMAC

        Chang, D.Y.,Lelieveld, J.,Tost, H.,Steil, B.,Pozzer, A.,Yoon, J. Pergamon Press ; Elsevier [distribution] 2017 Atmospheric environment Vol.162 No.-

        <P>This study uses the EMAC atmospheric chemistry-climate model to simulate cloud properties with a prognostic cloud droplet nucleation scheme. We present modeled global distributions of cloud condensation nuclei (CCN) number concentrations and CCN activation rates, together with the effective hygroscopicity parameter K, to describe the aerosol chemical composition effect on CCN activation. Large particles can easily activate into cloud droplets, even at low K values due to the dominant size effect in cloud droplet formation. Small particles are less efficiently activated as CCN, and are more sensitive to aerosol composition and supersaturation. Since the dominant fraction of small particles generally originates from anthropogenic precursor emissions over land, this study focuses on the influence of the continental atmosphere, using a prognostic cloud droplet nucleation scheme that considers aerosol cloud interactions during cloud formation, together with a double-moment cloud microphysics scheme. The agreement of simulated clouds and climate with observations generally improves over the Northern Hemisphere continents, particularly high air pollution regions such as Eastern US, Europe, East Asia by accounting for aerosol-cloud interactions that include impacts of chemical composition on CCN activation. (C) 2017 The Authors. Published by Elsevier Ltd.</P>

      • KCI등재

        Mechanical evaluation of the use of conventional and locking miniplate/screw systems used in sagittal split ramus osteotomy

        Zarina Tatia Barbosa Vieira Santos,Douglas Rangel Goulart,Eder Alberto Sigua Rodriguez,Leandro Pozzer,Sergio Olate,José,Ricardo Albergaria Barbosa 대한구강악안면외과학회 2017 대한구강악안면외과학회지 Vol.43 No.2

        Objectives: The aim of this study was to compare the mechanical resistance of four different osteosyntheses modeled in two different sagittal split ramus osteotomy (SSRO) designs and to determine the linear loading in a universal testing machine. Materials and Methods: An in vitro experiment was conducted with 40 polyurethane hemimandibles. The samples were divided into two groups based on osteotomy design; Group I, right angles between osteotomies and Group II, no right angles between osteotomies. In each group, the hemimandibles were distributed into four subgroups according to the osteosynthesis method, using one 4-hole 2.0 mm conventional or locking plate, with or without one bicortical screw with a length of 12.0 mm (hybrid technique). Each subgroup contained five samples and was subjected to a linear loading test in a universal testing machine. Results: The peak load and peak displacement were compared for statistical significance using PASW Statistics 18.0 (IBM Co., USA). In general, there was no difference between the peak load and peak displacement related to osteotomy design. However, when the subgroups were compared, the osteotomy without right angles offered higher mechanical resistance when one conventional or locking 2.0 mm plate was used. One locking plate with one bicortical screw showed higher mechanical resistance (162.72±42.55 N), and these results were statistically significantly compared to one conventional plate with monocortical screws (P=0.016) and one locking plate with monocortical screws (P=0.012). The difference in peak displacement was not statistically significant based on osteotomy design or internal fixation system configuration. Conclusion: The placement of one bicortical screw in the distal region promoted better stabilization of SSRO. The osteotomy design did not influence the mechanical behavior of SSRO when the hybrid technique was applied.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼