RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재

        Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

        De Molon, Rafael Scaf,Morais-Camillo, Juliana Aparecida Najarro Dearo,Sakakura, Celso Eduardo,Ferreira, Mauricio Goncalves,Loffredo, Leonor Castro Monteiro,Scaf, Gulnara Korean Academy of Oral and Maxillofacial Radiology 2012 Imaging Science in Dentistry Vol.42 No.4

        Purpose: This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Materials and Methods: Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. Results: There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm ($IC_{95%}$:6.04-6.54) and 6.79 mm ($IC_{95%}$:6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64mm($IC_{95%}$:6.40-6.89) and 6.79mm($IC_{95%}$:6.45-7.11), respectively. Conclusion: The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss.

      • KCI등재

        Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

        Rafael Scaf de Molon,Juliana Aparecida Najarro Dearo Morais-Camillo,Celso Eduardo Sakakura,Mauricio Goncalves Ferreira,Leonor Castro Monteiro Loffredo,Gulnara Scaf 대한구강악안면방사선학회 2012 Imaging Science in Dentistry Vol.42 No.4

        Purpose: This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Materials and Methods: Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student’s t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. Results: There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p¤|t|=0.0039), with means of 6.29 mm (IC95%:6.04-6.54) and 6.79 mm (IC95%:6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p¤|t|=0.4950), with means of 6.64mm(IC95%:6.40-6.89) and 6.79mm(IC95%:6.45-7.11), respectively. Conclusion: The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss.

      • KCI등재

        Evaluation of bone substitutes for treatment of peri-implant bone defects: biomechanical, histological, and immunohistochemical analyses in the rabbit tibia

        Pâmela Letícia dos Santos,Rafael Scaf de Molon,Thallita Pereira Queiroz,Roberta Okamoto,Ana Paula de Souza Faloni,Jéssica Lemos Gulinelli,Eloá Rodrigues Luvizuto,Idelmo Rangel Garcia Junior 대한치주과학회 2016 Journal of Periodontal & Implant Science Vol.46 No.3

        Purpose: We sought to evaluate the effectiveness of bone substitutes in circumferential periimplant defects created in the rabbit tibia. Methods: Thirty rabbits received 45 implants in their left and right tibia. A circumferential bone defect (6.1 mm in diameter/4 mm depth) was created in each rabbit tibia using a trephine bur. A dental implant (4.1 mm × 8.5 mm) was installed after the creation of the defect, providing a 2-mm gap. The bone defect gaps between the implant and the bone were randomly filled according to the following groups: blood clot (CO), particulate Bio-Oss® (BI), and Bio-Oss® Collagen (BC). Ten animals were euthanized after periods of 15, 30, and 60 days. Biomechanical analysis by means of the removal torque of the implants, as well as histologic and immunohistochemical analyses for protein expression of osteocalcin (OC), Runx2, OPG, RANKL, and TRAP were evaluated. Results: For biomechanics, BC showed a better biological response (61.00±15.28 Ncm) than CO (31.60±14.38 Ncm) at 30 days. Immunohistochemical analysis showed significantly different OC expression in CO and BC at 15 days, and also between the CO and BI groups, and between the CO and BC groups at 60 days. After 15 days, Runx2 expression was significantly different in the BI group compared to the CO and BC groups. RANKL expression was significantly different in the BI and CO groups and between the BI and BC groups at 15 days, and also between the BI and CO groups at 60 days. OPG expression was significantly higher at 60 days postoperatively in the BI group than the CO group. Conclusions: Collectively, our data indicate that, compared to CO and BI, BC offered better bone healing, which was characterized by greater RUNX2, OC, and OPG immunolabeling, and required greater reversal torque for implant removal. Indeed, along with BI, BC presents promising biomechanical and biological properties supporting its possible use in osteoconductive grafts for filling peri-implant gaps.

      • Facial and occlusal esthetic improvements of an adult skeletal Class III malocclusion using surgical, orthodontic, and implant treatment

        Mauricio de Almeida Cardoso,Rafael Scaf de Molon,Erica Dorigatti de Avila,Fabio Pinto Guedes,Valter Antonio Ban Battilani F,Leopoldino Capelozza Filho,Marcio Aurelio Correa,Hugo Nary Filho 대한치과교정학회 2016 대한치과교정학회지 Vol.46 No.1

        The aim of this clinical report is to describe the complex treatment of an adult Class III malocclusion patient who was disappointed with the outcome of a previous oral rehabilitation. Interdisciplinary treatment planning was performed with a primary indication for implant removal because of marginal bone loss and gingival recession, followed by orthodontic and surgical procedures to correct the esthetics and skeletal malocclusion. The comprehensive treatment approach included: (1) implant removal in the area of the central incisors; (2) combined orthodontic decompensation with mesial displacement and forced extrusion of the lateral incisors; (3) extraction of the lateral incisors and placement of new implants corresponding to the central incisors, which received provisional crowns; (4) orthognathic surgery for maxillary advancement to improve occlusal and facial relationships; and finally, (5) orthodontic refinement followed by definitive prosthetic rehabilitation of the maxillary central incisors and reshaping of the adjacent teeth. At the three-year follow-up, clinical and radiographic examinations showed successful replacement of the central incisors and improved skeletal and esthetic appearances. Moreover, a Class II molar relationship was obtained with an ideal overbite, overjet, and intercuspation. In conclusion, we report the successful esthetic anterior rehabilitation of a complex case in which interdisciplinary treatment planning improved facial harmony, provided gingival architecture with sufficient width and thickness, and improved smile esthetics, resulting in enhanced patient comfort and satisfaction. This clinical case report might be useful to improve facial esthetics and occlusion in patients with dentoalveolar and skeletal defects.

      • SCIESCOPUSKCI등재

        Evaluation of bone substitutes for treatment of peri-implant bone defects: biomechanical, histological, and immunohistochemical analyses in the rabbit tibia

        dos Santos, Pamela Leticia,de Molon, Rafael Scaf,Queiroz, Thallita Pereira,Okamoto, Roberta,de Souza Faloni, Ana Paula,Gulinelli, Jessica Lemos,Luvizuto, Eloa Rodrigues,Garcia, Idelmo Rangel Junior Korean Academy of Periodontology 2016 Journal of Periodontal & Implant Science Vol.46 No.3

        Purpose: We sought to evaluate the effectiveness of bone substitutes in circumferential periimplant defects created in the rabbit tibia. Methods: Thirty rabbits received 45 implants in their left and right tibia. A circumferential bone defect (6.1 mm in diameter/4 mm depth) was created in each rabbit tibia using a trephine bur. A dental implant ($4.1mm{\times}8.5mm$) was installed after the creation of the defect, providing a 2-mm gap. The bone defect gaps between the implant and the bone were randomly filled according to the following groups: blood clot (CO), particulate Bio-Oss$^{(R)}$ (BI), and Bio-Oss$^{(R)}$ Collagen (BC). Ten animals were euthanized after periods of 15, 30, and 60 days. Biomechanical analysis by means of the removal torque of the implants, as well as histologic and immunohistochemical analyses for protein expression of osteocalcin (OC), Runx2, OPG, RANKL, and TRAP were evaluated. Results: For biomechanics, BC showed a better biological response ($61.00{\pm}15.28Ncm$) than CO ($31.60{\pm}14.38Ncm$) at 30 days. Immunohistochemical analysis showed significantly different OC expression in CO and BC at 15 days, and also between the CO and BI groups, and between the CO and BC groups at 60 days. After 15 days, Runx2 expression was significantly different in the BI group compared to the CO and BC groups. RANKL expression was significantly different in the BI and CO groups and between the BI and BC groups at 15 days, and also between the BI and CO groups at 60 days. OPG expression was significantly higher at 60 days postoperatively in the BI group than the CO group. Conclusions: Collectively, our data indicate that, compared to CO and BI, BC offered better bone healing, which was characterized by greater RUNX2, OC, and OPG immunolabeling, and required greater reversal torque for implant removal. Indeed, along with BI, BC presents promising biomechanical and biological properties supporting its possible use in osteoconductive grafts for filling peri-implant gaps.

      • KCI등재

        The Use of qNMR for Quality Control of Coumarin-based Pharmaceuticals and Plant Medicines

        Luana C. Crocoli,Vinícius B. Molon,Sidnei Moura 한국생약학회 2021 Natural Product Sciences Vol.27 No.2

        The Coumarin (1,2-benzopyrone) is the main secondary metabolite of Mikania laevigata Sch. Beep ex Baker and Mikania glomerata Spreng., which are popularly known as guaco. These plants have been used mainly in traditional medicine in the treatment of respiratory diseases because their bronchodilator effect. However, there are around 200 species of Mikania, which are quite similar in appearance. From these, only M. leavigata and M. glomerata have high concentrations of coumarins. In this line, the falsification of products Mikania based has been frequent. In this sense, this work demonstrated the application of the easy, fast, e not destructive method based in Nuclear Magnetic Resonance in quantitative mode (qNMR) for the determination of coumarin in both commercial and homemade guaco products. Thus, in the first step the compounds were extract from guaco leaves and syrups using chloroform (CHCl3), with or without ultrasound. About the method, was linear with a R2= 0.9947 for 1,2-benzopyrone, with detection and quantification limits with were ​​ 0.11 and 0.36 mg mL-1 respectively. In the same line, the method was safe with RSD <0.3% and with recovery ranging from 93-101%. To confirm the applicability of the method, in the last step was applied to 10 real samples (6 from leaves and 4 from syrups). The content of the coumarin in the leaf extract ranged from 0.62 to 1.30 mg mL-1. For syrups I, II and IV, the content of coumarin was in accordance with the manufacturers. However, for de Syrup III, the concentration was 155% higher. In summary, the qNMR is a rapid method with minimal sample preparation that can be used to quantify coumarin in home-made plant extracts as well as in commercial samples as syrup for instance. This method is applicable for quality control of different plants-based products.

      • SCOPUSSCIEKCI등재

        Bone Cement Dislodgement : One of Complications Following Bone Cement Augmentation Procedures for Osteoporotic Spinal Fracture

        Ha, Kee-Yong,Kim, Young-Hoon,Yoo, Sung-Rim,Molon, Jan Noel The Korean Neurosurgical Society 2015 Journal of Korean neurosurgical society Vol.57 No.5

        Bone cement augmentation procedures have been getting more position as a minimally invasive surgical option for osteoporotic spinal fractures. However, complications related to these procedures have been increasingly reported. We describe a case of bone cement dislodgement following cement augmentation procedure for osteoporotic spinal fracture by reviewing the patient's medical records, imaging results and related literatures. A 73-year-old woman suffering back and buttock pain following a fall from level ground was diagnosed as an osteoporotic fracture of the 11th thoracic spine. Percutaneous kyphoplasty was performed for this lesion. Six weeks later, the patient complained of a recurrence of back and buttock pain. Radiologic images revealed superior dislodgement of bone cement through the 11th thoracic superior endplate with destruction of the lower part of the 10th thoracic spine. Staged anterior and posterior fusion was performed. Two years postoperatively, the patient carries on with her daily living without any significant disability. Delayed bone cement dislodgement can occur as one of complications following bone cement augmentation procedure for osteoporotic spinal fracture. It might be related to the presence of intravertebral cleft, lack of interdigitation of bone cement with the surrounding trabeculae, and possible damage of endplate during ballooning procedure.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼