Jung, Kwonsu,Kim, Woong,Park, Gwon Woo,Seo, Charles,Chang, Ho Nam,Kim, Yeu-Chun Springer-Verlag 2015 Applied microbiology and biotechnology Vol.99 No.7
<P>Response surface methodology (RSM) was used to optimize the production of volatile fatty acids (VFAs) and hydrogen from mixed anaerobic cultures of Saccharina japonica with respect to two independent variables: methanogenic inhibitor concentration and temperature. The effects of four methanogenic inhibitors on acidogenic processes were tested, and qualitative microbial analyses were carried out. Escherichia, Acinetobacter, and Clostridium were the most predominant genera in samples treated with chloroform (CHCl3), iodoform (CHI3), 2-bromoethanesulfonate (BES), or β-cyclodextrin (β-CD), respectively. RSM showed that the production of VFAs reached a peak of 12.5 g/L at 38.6 C in the presence of 7.4 g/L β-CD; these were the conditions under which hydrogen production was also nearly maximal. The quantitative polymerase chain reaction (qPCR) showed that shifts in the bacterial community population correlated with the concentrations of β-CD indicating that this compound effectively inhibited methanogens.</P>
몰리브덴(Mo) 특성방사선 획득을 위한 다층박막 거울의 최적 설계 및 공차 분석
천권수(Kwonsu Chon) 한국방사선학회 2009 한국방사선학회 논문지 Vol.3 No.4
단색 엑스선은 적은 방사선 피폭으로 대조도가 높은 의료영상을 만들 수 있다. 엑스선 튜브와 다층박막 거울을 결합하면 높은 플루언스의 단색 엑스선을 얻을 수 있다. 몰리브덴(Mo) 타깃을 갖는 엑스선 튜브에서 Mo 특성방사선(17.5keV)을 높은 반사율로 획득하기 위한 W/C 다층박막 거울의 최적화를 수행하였다. 반사율이 최대가 되는 조건에서 두께주기와 두께비를 결정하였다. 최적 설계된 다층박막 거울에 대한 두께주기와 브래그 정렬에 대한 공차를 구하였다. 증착 (deposition) 공차 0.2㎚와 회전정렬 공차 ± 0.01°에서 이론 반사율의 85% 이상에 해당하는 반사율이 얻어질 수 있다. 다층박막 거울을 이용하면 높은 플루언스의 특성방사선을 얻어 낼 수 있기 때문에 의료영상 획득 장치에 많이 사용될 것이다. Monochromatic X-ray can make a medical image of high contrast under a low radiation dose and can be easily generated by combining an X-ray tube and a multilayer mirror. A W/C multilayer mirror was optimally designed for a characteristic X-ray generated from a X-ray tube with Mo target. The d-spacing and the thickness ratio in design parameters were determined under the maximum-reflectivity condition. Tolerances for deposition and alignment of the W/C multilayer mirror were calculated. Within a deposition tolerance of 0.2㎚ and a alignment tolerance of ± 0.01°, 85% of the theoretical peak reflectivity could be achieved. A multilayer mirror can be widely used for making medical images because of generating high fluence monochromatic X-ray.
Noise Properties for Filtered Back Projection in CT Reconstruction
천권수(Kwonsu, Chon) 한국방사선학회 2014 한국방사선학회 논문지 Vol.8 No.6
전산화단층촬영장치의 영상재구성방법으로 필터보정역투영법이 광범위하게 사용되고 있다. 평행빔과 부채살빔의 재구성에 사용되는 투영에 잡음이 포함되었을 때 재구성 된 영상의 잡음을 살펴보았다. 평행빔과 부채살 구조에서 각각 360개, 720개의 투영으로 512 × 512 크기로 Visual C++을 이용하여 영상재구성하였고, 원본 Shepp-Logan 두부모형을 매우 잘 복원한다는 것을 확인하였다. 필터보정역투영법의 현실적인 접근(유한한 투영 개수)으로 인해 입력 잡음이 없어도 영상재구성 과정에서 잡음이 발생하였다. 입력 잡음비 0.5% 이하에서 잡음이 빠르게 증가하기 때문에 CT 장치의 잡음 제거 기술 및 영상처리 기법의 개발이 필요할 것이다. The filtered back projection in the image reconstruction algorithms for the clinic computed tomography system has been widely used. Noise of the reconstructed image was examined under the input noise for parallel and fan beam geometries. The reconstruction images of 512 × 512 size were carried out under 360 and 720 projection by the Visual C++ for parallel beam and fan beam, respectively, and those agreed with the original Shepp-Logan head phantom very much. Noise was generated because of intrinsic restriction (finite number of projections) for the image reconstruction algorithm, filtered back projection, when no input noise was applied. Because the result noise was rapidly increased under 0.5% input noise ratio, technologies for reducing noise in CT system and image processing is important.