        Suitability of Palm Based Oil as Dielectric Insulating Fluid in Transformers

        Norhafiz Azis,Jasronita Jasni,Mohd Zainal Abidin Ab Kadir,Mohd Nazim Mohtar 대한전기학회 2014 Journal of Electrical Engineering & Technology Vol.9 No.2

        Mineral oil has been widely used as dielectric insulating fluid in transformers due to its excellent performance in-service. However, there are few issues with mineral oil such as it has poor biodegradability and could contaminate the environment if a spillage occurs. With the increasing tight regulation on safety and environment, alternative fluids for mineral oil are currently being investigated and among the suitable candidate is the vegetable oil. There are different types of vegetable oils and one of them is the palm based oil. At the moment, extensive research works are carried out to examine its feasibility to be applied in transformers. This paper will review the previous research works that were carried out to examine the suitability of palm based oil as dielectric insulating fluid in transformers. The physical and chemical properties of palm based oil are studied based on viscosity, acidity, oxidation stability and flash point. Next, the electrical characteristics of palm based oil are examined based on AC breakdown voltage, relative permittivity, dissipation factor and partial discharge.

      • SCIESCOPUSKCI등재

        Suitability of Palm Based Oil as Dielectric Insulating Fluid in Transformers

        Azis, Norhafiz,Jasni, Jasronita,Kadir, Mohd Zainal Abidin Ab,Mohtar, Mohd Nazim The Korean Institute of Electrical Engineers 2014 Journal of Electrical Engineering & Technology Vol.9 No.2

        Mineral oil has been widely used as dielectric insulating fluid in transformers due to its excellent performance in-service. However, there are few issues with mineral oil such as it has poor biodegradability and could contaminate the environment if a spillage occurs. With the increasing tight regulation on safety and environment, alternative fluids for mineral oil are currently being investigated and among the suitable candidate is the vegetable oil. There are different types of vegetable oils and one of them is the palm based oil. At the moment, extensive research works are carried out to examine its feasibility to be applied in transformers. This paper will review the previous research works that were carried out to examine the suitability of palm based oil as dielectric insulating fluid in transformers. The physical and chemical properties of palm based oil are studied based on viscosity, acidity, oxidation stability and flash point. Next, the electrical characteristics of palm based oil are examined based on AC breakdown voltage, relative permittivity, dissipation factor and partial discharge.

      • KCI등재

        Evaluation on the Lightning Breakdown Voltages of Palm Oil and Coconut Oil under Non-Uniform Field at Small Gap Distances

        Yee Von Thien,Norhafiz Azis,Jasronita Jasni,Mohd Zainal Abidin Ab Kadir,Robiah Yunus,Mohd Taufiq Ishak,Zaini Yaakub 대한전기학회 2016 Journal of Electrical Engineering & Technology Vol.11 No.1

        In recent years, there are a number of studies that have been carried out to explore the alternative for Mineral Oil (MO) as dielectric insulating fluid in transformers due to the increasing tight regulation on safety and environment. Vegetable oils have been identified as suitable candidate since it is biodegradable, non-toxic and high flash/fire points which ensure more in-service safety. Among the types of vegetable oils considered for transformers application are Palm Oil (PO) and Coconut Oil (CO). This paper presents an experimental study on the lightning breakdown voltages of PO and CO under non-uniform electric field based on needle-sphere electrodes configuration at 3 small gap distances. The type of PO used in this study is Refined Bleached and Deodorized Palm Oil (RBDPO) Olein. The main focus of this study is to examine the lightning breakdown performance of RBDPO and CO under different test conditions and assess its suitability as dielectric insulating fluid in transformers. The effect of voltage polarities (positive and negative) and testing methods (risingvoltage, up-and-down and multiple-voltage) were investigated. The data obtained from all tests were analysed by Weibull distribution in order to determine the withstand voltages for each type of oils. It was found that the breakdown voltages of RBDPO and CO are comparable with MO under positive lightning impulse. Under negative lightning impulse, the breakdown voltage of MO is slightly higher than RBDPO and CO. There is no significant effect of testing methods and voltage polarities on lightning breakdown voltages of RBDPO and CO. Based on the statistical analysis, it is found that the breakdown voltages of RBDPO and CO at 1% probability are slightly lower than MO.

      • KCI등재

        Investigation on the Dielectric, Physical and Chemical Properties of Palm Oil and Coconut Oil under Open Thermal Ageing Condition

        Nur Aqilah Mohamad,Norhafiz Azis,Jasronita Jasni,Mohd Zainal Abidin Ab Kadir,Robiah Yunus,Mohd Taufiq Ishak,Zaini Yaakub 대한전기학회 2016 Journal of Electrical Engineering & Technology Vol.11 No.3

        In this paper, a study is carried out to investigate the dielectric, physical and chemical properties of Palm Oil (PO) and Coconut Oil (CO) under open thermal ageing condition. The type of PO used in this study is Refined Bleached and Deodorized Palm Oil (RBDPO) Olein. The ageing experiment was carried out at 85 °C and 115 °C for 1, 3, 5, 7 and 14 days. Several parameters were measured such as AC breakdown voltage, dielectric dissipation factor, relative permittivity, resistivity, viscosity, moisture and acidity throughout the ageing duration. Based on the study, it is found that there are no significant changes on the AC breakdown voltages and relative permittivities for both RBDPO and CO. At ageing temperature of 115°C, there are clear reduction trends of dielectric dissipation factor for CO and resistivities for most of RBDPO. On the other hand, no clear trends are observed for viscosities, moisture and acidities of RBDPO and CO throughout the ageing duration.

      • SCIESCOPUSKCI등재

        Investigation on the Dielectric, Physical and Chemical Properties of Palm Oil and Coconut Oil under Open Thermal Ageing Condition

        Mohamad, Nur Aqilah,Azis, Norhafiz,Jasni, Jasronita,Kadir, Mohd Zainal Abidin Ab,Yunus, Robiah,Ishak, Mohd Taufiq,Yaakub, Zaini The Korean Institute of Electrical Engineers 2016 Journal of Electrical Engineering & Technology Vol.11 No.3

        In this paper, a study is carried out to investigate the dielectric, physical and chemical properties of Palm Oil (PO) and Coconut Oil (CO) under open thermal ageing condition. The type of PO used in this study is Refined Bleached and Deodorized Palm Oil (RBDPO) Olein. The ageing experiment was carried out at 85 ℃ and 115 ℃ for 1, 3, 5, 7 and 14 days. Several parameters were measured such as AC breakdown voltage, dielectric dissipation factor, relative permittivity, resistivity, viscosity, moisture and acidity throughout the ageing duration. Based on the study, it is found that there are no significant changes on the AC breakdown voltages and relative permittivities for both RBDPO and CO. At ageing temperature of 115℃, there are clear reduction trends of dielectric dissipation factor for CO and resistivities for most of RBDPO. On the other hand, no clear trends are observed for viscosities, moisture and acidities of RBDPO and CO throughout the ageing duration.

      • SCIESCOPUSKCI등재

        Evaluation on the Lightning Breakdown Voltages of Palm Oil and Coconut Oil under Non-Uniform Field at Small Gap Distances

        Thien, Yee Von,Azis, Norhafiz,Jasni, Jasronita,Kadir, Mohd Zainal Abidin Ab,Yunus, Robiah,Ishak, Mohd Taufiq,Yaakub, Zaini The Korean Institute of Electrical Engineers 2016 Journal of Electrical Engineering & Technology Vol.11 No.1

        In recent years, there are a number of studies that have been carried out to explore the alternative for Mineral Oil (MO) as dielectric insulating fluid in transformers due to the increasing tight regulation on safety and environment. Vegetable oils have been identified as suitable candidate since it is biodegradable, non-toxic and high flash/fire points which ensure more in-service safety. Among the types of vegetable oils considered for transformers application are Palm Oil (PO) and Coconut Oil (CO). This paper presents an experimental study on the lightning breakdown voltages of PO and CO under non-uniform electric field based on needle-sphere electrodes configuration at 3 small gap distances. The type of PO used in this study is Refined Bleached and Deodorized Palm Oil (RBDPO) Olein. The main focus of this study is to examine the lightning breakdown performance of RBDPO and CO under different test conditions and assess its suitability as dielectric insulating fluid in transformers. The effect of voltage polarities (positive and negative) and testing methods (rising-voltage, up-and-down and multiple-voltage) were investigated. The data obtained from all tests were analysed by Weibull distribution in order to determine the withstand voltages for each type of oils. It was found that the breakdown voltages of RBDPO and CO are comparable with MO under positive lightning impulse. Under negative lightning impulse, the breakdown voltage of MO is slightly higher than RBDPO and CO. There is no significant effect of testing methods and voltage polarities on lightning breakdown voltages of RBDPO and CO. Based on the statistical analysis, it is found that the breakdown voltages of RBDPO and CO at 1% probability are slightly lower than MO.