http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
K.Izaki,I.hirota,H.Yamashita,H.Omon,K.Matsumoto,K.Nishida,J.M.Sun,M.Nakaoka 전력전자학회 1998 ICPE(ISPE)논문집 Vol.- No.-
This paper describes an advanced prototype of voltage-fed zero voltage soft-switching PWM resonant inverter with an active voltage clamped capacitor, which is put into practice for high-frequency high-power induction-heated appliances This application-specific quasi-resonant inverter using the latest generation IGBTs for soft-switching can regulate its output power under a principle of a fixed frequency ZVS-PWM strategy. Its operating principle and unique features are presented as compared with a conventional quasi-resonant ZVS inverter for induction-heated cooker, together with its power regulation characteristics on the basis of its simulation and experimental results. The steady-state performances of this inverter developed for mutli-bumer type induction-heated food cooking appliance are evaluated and discussed from a practical point of view.<br/>
Kaga, Horoyuki,Izaki, Noriaki,Shimomura, Yasuhiko,Masuda, Noboru The Korean Institute of Landscape Architecture 2001 Journal of the Korean institute of landscape archi Vol.1 No.-
Now that importance of landscape planning unique to each area is emphasized, it is necessary to conduct landscape planning by taking advantage of natural environments unique to each ares, because its natural environments are regarded as one of the assets the area possesses. This study targets at Kawachinagano City, Osaka, one of the residential areas that I not only rich in natural and historical elements, but also has been rapidly growing. The purposes of this study are to evaluate change in landscape structure over time by analyzing relation between landform and pattern of expanding the built-up area at three time points of 1932, 1967, and 1994 with GIS (ARC/INFO 7.0.3, ARC/View 3.0 (ESRI)), as well as to make some suggestions for planning landscape unique to the area. Data on main ridges, sub ridges, main rivers, and other landform were read from the elevation map, and data on woodland, and parks and open spaces (having more than 3 ha area) were read from the existing land use map. The data were used to understand the natural structure of the city from topographic viewpoint. Next, the existing land use map prepared with data on the built-up area and urban axes consisting of roads and streets were overlaid on the elevation map in order to understand relation between pattern of expanding the built-up area and the natural structure.
Hayakawa, Kazuichi,Tang, Ning,Sato, Kosuke,Izaki, Akihiko,Tatematsu, Michiya,Hama, Hirotaka,Li, Ying,Kameda, Takayuki,Toriba, Akira Korean Society for Atmospheric Environment 2011 Asian Journal of Atmospheric Environment (AJAE) Vol.5 No.3
1-Nitropyrene (1-NP), 2-NP and 2-nitrofluoranthene (2-NFR) are useful markers for studying the atmospheric behaviors of polycyclic aromatic hydrocarbons (PAHs) and nitropolycyclic aromatic hydrocarbons (NPAHs). However, present methods for measuring trace levels of these compounds are lesssensitive and laborious. Here we describe several improvements to a previously reported high-performance liquid chromatography-chemiluminescence detection system that allows it to determine trace levels of 1-, 2-NPs and 2-NFR. The proposed system was equipped with a reducer column packed with Pt/Rh instead of zinc whose life-time was limited. The combination of Cosmosil MS-II (monomeric ODS) and AR-II (polymeric ODS) columns was used instead of polymeric ODS columns as the separator column to improve the separation. An ethanol mixture with acetate buffer (pH 5.5) was used in place of an acetonitrile mixture with the same buffer to activate the reducer column. The same ethanol mixture was used as the mobile phase for the clean-up column. The switching time of the column switching valve was optimized to concentrate the amino-derivatives of above NPAHs quantitatively on the concentrator column. The concentrations of bis(2,4,6-trichlorophenly) oxalate and hydrogen peroxide in the chemiluminescence reagent solution were optimized to 0.4 mM and 30 mM, respectively, to increase the sensitivity. Under the above conditions, the detection limits (S/N=3) of 1-, 2-NPs and 2-NFR were 1 fmol (0.25 pg), 10 fmol (2.5 pg) and 4 fmol (1 pg), respectively. The proposed system was effectively used to determine trace levels of 1-, 2-NPs and 2-NFR in airborne particulates collected at Noto Peninsula. The atmospheric concentrations of 1-, 2-NPs and 2-NFR were not more than sub pg $m^{-3}$ levels. They were higher in winter (January) than in summer (July). In both seasons, the concentrations were in decreasing order, [2-NFR]>[1-NP]>[2-NP].
Kazuichi Hayakawa,Ning Tang,Akihiko Izaki,Michiya Tatematsu,Hirotaka Hama,Ying Li,Takayuki Kameda,Akira Toriba 한국대기환경학회 2011 Asian Journal of Atmospheric Environment (AJAE) Vol.5 No.3
1-Nitropyrene (1-NP), 2-NP and 2-nitrofluoranthene (2-NFR) are useful markers for studying the atmospheric behaviors of polycyclic aromatic hydrocarbons (PAHs) and nitropolycyclic aromatic hydrocarbons (NPAHs). However, present methods for measuring trace levels of these compounds are lesssensitive and laborious. Here we describe several improvements to a previously reported high-performance liquid chromatography-chemiluminescence detection system that allows it to determine trace levels of 1-, 2-NPs and 2-NFR. The proposed system was equipped with a reducer column packed with Pt/Rh instead of zinc whose life-time was limited. The combination of Cosmosil MS-II (monomeric ODS)and AR-II (polymeric ODS) columns was used instead of polymeric ODS columns as the separator column to improve the separation. An ethanol mixture with acetate buffer (pH 5.5) was used in place of an acetonitrile mixture with the same buffer to activate the reducer column. The same ethanol mixture was used as the mobile phase for the clean-up column. The switching time of the column switching valve was optimized to concentrate the amino-derivatives of above NPAHs quantitatively on the concentrator column. The concentrations of bis(2,4,6-trichlorophenly)oxalate and hydrogen peroxide in the chemiluminescence reagent solution were optimized to 0.4 mM and 30 mM, respectively, to increase the sensitivity. Under the above conditions, the detection limits (S/N =3) of 1-, 2-NPs and 2-NFR were 1 fmol (0.25 pg),10 fmol (2.5 pg) and 4 fmol (1 pg), respectively. The proposed system was effectively used to determine trace levels of 1-, 2-NPs and 2-NFR in airborne particulates collected at Noto Peninsula. The atmospheric concentrations of 1-, 2-NPs and 2-NFR were not more than sub pg m^-3 levels. They were higher in winter (January) than in summer (July). In both seasons,the concentrations were in decreasing order,[2-NFR]>[1-NP]>[2-NP].