Improvement of the Thermo-Mechanical Position Stability of the Beam Position Monitor in the PLS-II
Taekyun Ha,Mansu Hong,Hyuckchae Kwon,Hongsik Han,Chongdo Park 한국물리학회 2016 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.69 No.6
In the storage ring of the Pohang Light Source-II (PLS-II), we reduced the mechanical displacement of the electron-beam position monitors (e-BPMs) that is caused by heating during e-beam storage. The BPM pickup itself must be kept stable to sub-micrometer precision in order for a stable photon beam to be provided to beamlines because the orbit feedback system is programmed to make the electron beam pass through the center of the BPM. Thermal deformation of the vacuum chambers on which the BPM pickups are mounted is inevitable when the electron beam current is changed by an unintended beam abort. We reduced this deformation by improving the vacuum chamber support and by enhancing the water cooling. We report a thermo-mechanical analysis and displacement measurements for the BPM pickups after improvements.