http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
타일 금형 라이너 및 끼움재의 열박음 공차 및 결합력에 대한 해석적 연구
임동욱,이정식,정영호,최두선,고강호,이정우,김재훈,Lim, Dong Wook,Lee, Jeong Sik,Jeong, Young Ho,Choi, Doo Sun,Ko, Kang-Ho,Lee, Jeong-woo,Kim, Ji-Hun 한국금형공학회 2020 한국금형공학회지 Vol.14 No.3
Ceramic tile is widely used as a floor or interior decoration of buildings. The main processes are raw material blending, molding, drying, firing, etc., and since dimensional and quality stability are very important, they are generally molded by a dry press method. In ceramic tile molds, there is a liner that can be easily replaced in case of wear. The liner is constantly abrasion due to a continuous pressing process during tile forming, and it is required to be replaced every certain period. Even in the liner, use a wear-resistant fitting material only in areas where wear is concentrated. However, there was a risk that the fitting material was applied to large-sized tile molding due to problems such as damage to the molding machine and decrease in productivity when detached during the actual tile molding process due to weak fitting strength with the liner. Therefore, in this study, thermal-structural analysis for fitting tolerance analysis and structural analysis for fitting force analysis were performed for the shrink fit process of the fitting material.
MR fluid를 이용한 알루미늄 표면의 초정밀 연마 방법
임동욱,김병찬,홍광표,조명우,Lim, Dong-Wook,Kim, Byung-Chan,Hong, Kwang-Pyo,Cho, Myung-Woo 한국금형공학회 2017 한국금형공학회지 Vol.11 No.2
Recent industrial developments are constantly advancing, and rapid technological development is demanding high technology level in related fields. The need for polishing is increasing even more to improve quality. In order to improve the surface quality, the final finishing process or polishing process is a very important part. Research on super precise polishing method using MR fluid is actively being carried out in domestic and foreign countries. Fine magnetic abrasive grains are aligned in the direction of a magnetic force line formed by a magnetic field and serve as a brush to polish a metal surface. This method has the advantage that the shape of the tool is not fixed and is not affected by the shape of the workpiece or the machining area. We will design the electromagnets for the MR polish polishing system and apply the magnetic field analysis using the magnetic field analysis program (ANSYS). The data obtained through this process suggests an efficient method to increase the magnetic flux density important for polishing. We will investigate the influence of the Al6061-T6 specimen on the surface of the MR polishing machine based on the optimized design.
Calcium and CN bimodality of RGB stars in Globular clusters with Multiple Populations
임동욱,노동구,한상일,이영욱,Lim, Dongwook,Roh, Dong-Goo,Han, Sang-Il,Lee, Young-Wook 한국천문학회 2012 天文學會報 Vol.37 No.2
A number of recent observations have established that many globular clusters have double or multiple stellar populations. In particular, recent Calcium and Stromgren b & photometry shows a split in the RGB of some of these globular clusters, including M22, NGC 1851, and NGC 288. However, the origin of this split in the RGB is still controversial. In order to confirm the real difference in Calcium abundance between the two RGBs, we have performed low resolution spectroscopy for RGB stars in these globular clusters. The spectral data were obtained from WFCCD/duPont 2.5m telescope in Las Campanas Observatory. We found a significant bimodality of both Calcium and CN abundances in M22 and NGC 1851. NGC 288, however, shows a clear bimodality only in CN abundance.
유한요소법을 이용한 유압브레이커 Cylinder와 Piston의 열-구조 연성해석을 통한 안정성 평가
임동욱,박윤수,신봉철,Lim, Dong-Wook,Park, Yoon-Soo,Shin, Bong-Cheol 한국금형공학회 2018 한국금형공학회지 Vol.12 No.1
This study proves the causes of cylinder and piston jam by scratches which is the fatal problem of hydraulic breaker through the thermal analysis and thermal-structural coupled field analysis. The trouble from the scratch is a complex problem which can be caused by manufacturing process (this is an internal factor) and the users mistake or contamination in the hydraulic circuit (these are an external factor). Hence, it's not easy to investigate the causes, also hard to prevent the recurrence. In this reason, hydraulic breaker manufacturers are trying to improve the manufacturing process such as machining, heat treatment, grinding, cleaning, also to prevent the contamination in hydraulic circuit and to remove the remains. It's being managed thoroughly by manufacturers. This study shows the effect of the temperature rise by the frictional heat generated when the piston hits the tool on the hydraulic oil while the hydraulic breaker is operating, also the temperature distribution when it starts to affect main components of hydraulic breaker. The stress and the amount of deformation also could be found through thermal-structural coupled field analysis. It proved that the stress and deformation are proportionally increased according to the temperature rise in hit area, and it affects the cylinder and the viscosity of hydraulic oil inside the cylinder when it heats up beyond the certain temperature.
임동욱,최두선,김태민,박정래,박규백,함휘찬,김지훈,Lim, Dong-Wook,Choi, Doo-Sun,Kim, Tae-min,Park, Jung-Rae,Park, Kyu-Bag,Ham, Hwi-Chan,Kim, Ji-Hun 한국금형공학회 2020 한국금형공학회지 Vol.14 No.3
In the drug delivery system industry, the technology with even split injection becomes important for maximizing efficiency and minimizing the side effects. In conventional drug delivery system, infection can occur due to pain and splashing. Also, various applications are impossible due to disposable use, and it is the reason to avoid to use this system because of the complexity of the driving method. Therefore, in this study, a painless drug delivery device is developed for non-pain with electrical insulation breakdown method. Finite elements analysis was used to evaluate the ejection characteristics of drugs according to the shape of the micro ejection nozzle. The effect of the number of holes in the micro nozzle, the length of the nozzle and the inner shape of the nozzle on the drug discharge characteristics were analyzed.
임동욱,김지훈,신봉철,Lim, Dong-Wook,Kim, Ji-Hun,Shin, Bong-Cheol 한국금형공학회 2018 한국금형공학회지 Vol.12 No.1
Both injection and injection molding dies have evolved into advanced technology. Product quality is also evolving day after day. Therefore, the conditions of the injection mold and the injection conditions are becoming important. In order to improve the quality of the product, the Hardware part of the mold has developed as an advanced technology, and the Software part has also developed with advanced technology. This study deals with the cooling part, which is part of the hardware. In addition to fluid cooling, which is commonly used in the industry, by using gas cooling identify the phenomena that appear on the surface of the product and the critical point strain of the product to find the optimal cooling. Electronic parts and automobile parts whose surface condition is important, the cooling process is important to such a degree that they are divided with good products and defective products according to the cooling process at the time of injection. By controlling this important cooling and reducing the injection time with additional cooling, the product quality can be increased to the highest production efficiency. In addition, high efficiency can be achieved without additional investment costs. This study was conducted to apply these various advantages in the field.
한약복합물 HT008이 흰쥐 관절염 모델에 미치는 효과
임동욱 ( Dong Wook Lim ),김미연 ( Mi Yeon Kim ),송미경 ( Mi Kyung Song ),김지영 ( Ji Young Kim ),이동헌 ( Dong Hun Lee ),박주연 ( Ju Yeon Park ),부영민 ( Young Min Bu ),김호철 ( Ho Cheol Kim ) 대한본초학회 2009 大韓本草學會誌 Vol.24 No.4
Objectives: This study was conducted to investigate the effect of HT008, a multi-herbal mixture consisting of 3 herbs, Eleutherococcus senticosus, Angelica sinensis, and Scutellaria baicaleinsis on arthritic model in rats. Methods: The anti-inflammatory and analgesic activities were observed by utilizing the following models: carrageenan-induced edema of the hind paw of rats, acetic acid-induced writhing response in mice. The perimeter of the paw was measured before injection and then at 1, 2, 4, 6 h after injection of 1% λ-carrageenan. The HT008 at five dose levels (10, 30, 100, and 300 mg/kg) and distilled water given 30 min to treatment groups and control group, before λ-carrageenan injection. In the writhing test, the mice received 0.7% acetic acid solution in normal saline injected intraperitoneally at a dose of 10 ml/kg. The number of writhes was counted staring 10 min after injection. Results: HT008 at four dose levels (30, 100, and 300 mg/kg) significantly decreased the carrageenan-induced rat paw edema perimeter. E. senticosus and S. baicaleinsis extracts reduced acetic acid-induced writhing response in mice. Also A. sinensis extracts significantly decreased the carrageenan-induced rat paw edema perimeter. Conclusions: These results show that HT008, a multi-herbal mixture has both anti-inflammatory activity and analgesic effects in vivo arthritic model, and suggest that HT008 could be a good therapy to treat human osteoarthritis.
전기 자극으로 유발한 음경 발기력 측정 흰쥐 모델에 대한 HTE001의 발기력 상승효과
임동욱 ( Dong Wook Lim ),이동헌 ( Dong Hun Lee ),송미경 ( Mi Kyoung Song ),김미연 ( Mi Yeon Kim ),부영민 ( Young Min Bu ),김호철 ( Ho Cheol Kim ) 대한본초학회 2009 大韓本草學會誌 Vol.24 No.3
Objectives: This study was conducted to investigate the effect of HTE001, a multi-herbal mixture consisting of 10 herbs, Cornus Frutus, Schizandrae Fructus, Rubi Fructus, Cnidi Fructus, Acanthopanacis senticosi Radix, Cinnamomi Cortex, Eucommiae Cortex, Allii Bulbus, Rehmanniae Radix and Ginseng Radix, on electrostimulation-induced penile erection in rats. Methods: Intracavernous pressure (ICP) and mean arterial blood pressure (MAP) were simultaneously monitored through electric stimulation of the cavernous nerve after the oral administration of HTE001 (30, 100, 300 mg/kg) in normal rats. Statistical analysis was performed on maximal intracavernous pressure (ICP), maximal intracavernous pressure/mean arterial blood pressure (ICP/MAP) ratio, and the area under the curve (AUC) of ICP/MAP ratio. Results: Oral administration of HTE001 300 mg/kg caused the ICP to increase in a frequency-dependent manner. And HTE001 300 mg/kg treatment group showed the highest value in the ICP/MAP ratio and the AUC value of the ICP/MAP ratio compared to the control group at 2 Hz, 6 Hz and 10 Hz, respectively without an effect on the mean arterial blood pressure under the same stimulation of the cavernous nerve. Conclusions: These results show that HTE001 improve penile erection and prolong the decay period in normal rats without affecting mean arterial blood pressure, and suggest that HTE001 could be a good therapeutic candidate to treat erectile dysfunction.