RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • 한국 여성에서 sALP(Skeletal Alkaline Phosphatase) 참조치 설정에 관한 연구

        천준홍 ( Jun Hong Cheon ),최우준 ( Woo Joon Choi ),문형호 ( Hyoung Ho Moon ),정윤영 ( Yoon Young Chung ),이승관 ( Seung Gwan Lee ) 대한임상검사과학회 1998 대한임상검사과학회지(KJCLS) Vol.30 No.2

        sALP(Skeletal Alkaline Phosphatase), a tetrameric glycoprotein is localized in the plasma membrane of the Osteoblast and is released into the circulation as a dimer. Serum level of sALP are believed to reflect the metabolic state of osteoblast. We measured serum sALP with a immunoradiometric assay(IRMA} in a large sample of healthy korean women. In this study we have analyzed reference values of sALP obtained from some healthy korean women by means of AIC(Akaike’s Information Criterion) method. Following results were obtained. 1. In total group, it had showen that the optimal model for normal distribution was the power function [f(x}=ln(x)] with reference range of 5 - 31 μ g/L. 2. Power function were the predominant one in all age groups, with reference ranges of 5 - 18μg/L, 5 - 23μg/L, 6 - 32μg/L, 6 - 30μg/L in 30s, 40s, 50s, and 60s of female.

      • Discovery NM 530c(D530c)에서 촬영한 심근관류 SPECT 환자의 움직임 감소활동을 위한 연구

        이동훈,최우준,정우영,Lee, Dong Hun,Choi, Woo Jun,Jung, Woo Young 대한핵의학기술학회 2017 핵의학 기술 Vol.21 No.2

        D530c는 cadmium zinc telluride (CZT) detector가 심장을 중심으로 배열되어 회전 없이 짧은 시간에 검사가 가능하며 높은 해상도의 영상획득이 가능하다. 하지만 이러한 구조적 특성으로 인해 환자의 움직임에 민감하며, 검사 결과에도 일부분 영향을 미칠 수 있다. 이에 본 연구에서는 D530c에서 검사 중 발생되는 환자의 움직임 감소 활동을 통해 영상 품질의 최적화를 목적으로 한다. 환자의 다양한 움직임 원인을 분석하여 호흡보정 도구 제작, 환자의 호흡 및 움직임에 관한 주의사항 교육 등의 개선활동을 시행하였다. 개선 전 대상으로 2016년 11월에 D530c에서 심근관류 SPECT를 시행한 환자 70명을 선정하였고, 개선 후 2017년 2월 14일부터 2017년 2월 21일까지 시행한 환자 70명을 대상으로 하였다. 검사 시작 전 위치에서 X, Y, Z 축으로 이동된 심장의 변동거리(4 mm, 8 mm, 12 mm 이상)별 움직임 발생시간을 측정하여 개선 전 후 Stress와 Rest 영상을 각각 비교 분석하였다. 개선활동 후 심장의 움직임 발생시간이 stress와 rest 영상에서 모두 감소되었으며, 특히 stress 영상에서 12 mm 이상의 큰 움직임 발생횟수가 0회(발생시간 0초)로 기록되었다. 심장의 위치가 X축으로 4 mm, 8 mm 변동된 발생시간과 Z축으로 8 mm 변동된 발생시간은 통계적으로 유의한 차이가 있었지만(p<0.005), 그 외 stress와 rest의 모든 구간의 발생시간은 유의한 차이가 없었다(p>0.005). 호흡에 의해서도 발생 가능한 4 mm 변동거리에 따른 움직임 발생시간의 감소는 교육 및 움직임 방지 도구를 통해 검사 중 환자의 호흡이 보정된 결과로 파악되며, 호흡 이외의 환자의 실제 움직임으로 발생되었을 것으로 예상되는 8 mm, 12 mm 이상의 변동거리에 따른 움직임 발생시간 감소를 통해 영상 품질의 향상을 가져올 것으로 예상된다. Purpose The D530c have cadmium zinc telluride(CZT) detectors that are arranged focus on the heart. This structural characteristic allows for quicker imaging without rotation, but this is sensitive to patient movement and can affect the test results. The aim of this study is to optimize the image quality by reducing patient movement during the examination. Materials and Methods We analyzed the patients' movements, and performed various activities such as provided patient education about correct breathing techniques and avoiding patient movements, and created breathing correction tools to minimize patient movement during exam. The 70 patients who underwent myocardial perfusion SPECT with D530c in November 2016 were categorized as the group before the corrective steps. Another 70 patients who underwent the procedure with D530c from February 14, 2017 to February 21, 2017 were categorized as the improvement group. Images acquired during stress and at rest were compared and analyzed by measuring the durations of heart movements over certain distances (4 mm, 8 mm, 12 mm, or more) noted on the x-, y-, and zaxes. Results After the activities, the durations of heart movements decreased in the images acquired both under stress and at rest. In particular, there were no large motions greater than 12 mm recorded in the stress images after the improvement. There was a significant difference (p<0.005) in the 4-mm and 8-mm fluctuations on the X-axis and the 8-mm fluctuations on the Z axis in the stress images, but there was no significant difference (p>0.005) in the other stress and rest intervals. Conclusion The decrease in the time of motion occurrence due to the 4 mm fluctuation distance that can occur through breathing can be understood as a result of the breathing being corrected through training and motion prevention tools. It is expected that the image quality will be improved by reducing the occurrence time according to the variation distance of 8 mm or 12 mm, which is expected as the actual movement of the patient other than the breathing.

      • 부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가

        강영은,김은혜,김호성,최종숙,최우준,Kang, Young-Eun,Kim, Eun-Hye,Kim, Ho-Sung,Choi, Jong-Sook,Choi, Woo-Jun 대한핵의학기술학회 2011 핵의학 기술 Vol.15 No.1

        Purpose: Generally dual energy X-ray absorptiometry has been used for the purpose of evaluation of osteoporosis and treatment. Recently the interest of obesity came to be high and body percent fat test is increasing. Existing measure of body fat have to scan the whole body can be evaluated, but only lumbar spine and hip measurements was assumed to be whole body fat as well as improving the software. It tries to check whether the part measured value not being whole body measurement has the validity or not compared with the value calculated with the method that it is different, it forgives through a correlation with a (BIA) and (BMI). Materials and Methods: In 2010, the body percent fat was measured among the examinee coming to the Asan Medical Center public health care center from March till August against 90 females more than 40 years old through (DXA) and BIA. BMI utilized the value which wrote an hight and weight measured through the body measuring instrument in the examinee information and is automatically calculated. In addition, it classified as the low weight ($13-18.5kg/m^2$), normal ($18.5-25kg/m^2$), and corpulence ($25-30kg/m^2$) based on BMI and so that it could check whether there was the difference according to the weight or not BMI and BIA and correlation between DXA were analyzed in each group. The statistical program for the analysis used SPSS 12.0. Results: The comparison of DXA at 3 which it divides into the low weight and normal and corpulence groups and BIA did not show the difference noted statistically in all groups and the between group comparison was exposed to do not have a meaning. The body percent fat measured by the correlation analysis result DXA at the state that it doesn't divide into the group showed the high correlation (r=0.908, p0.01) noted statistically compared with BMI and showed the high correlation noted statistically in a comparison with BIA (r=0.927, p0.01). Conclusion: It confirmed that the whole body percent fat presumed from the part bone density measurement showed the excel correlation compared with BIA and BMI and information is high. There is still no clear standard about the presumed whole body percent fat and it is difficult to evaluate the fat evaluation by the bone mineral density measurement. However, it is determined that the information offering which is more objective through the comparative study with the body percent fat which is very efficient and in that it can obtain till the information about a fat as well as diagnosis of the osteoporosis through the bone density checkup is measured by the afterward telegraph bone density checkup and is clinically useful is possible. 이중에너지 방사선 흡수계측법(Dual-energy X-ray Apsorptiometry, DXA)은 일반적으로 골밀도를 통한 골다공증 평가 및 치료목적으로 이용되어 왔으며 최근 비만에 대한 관심이 높아지면서 체지방검사 처방이 증가하고 있는 추세이다. 기존의 체지방 측정은 전신을 검사해야만 평가가 가능했지만 근래 DXA장비의 소프트웨어가 향상 되면서 요추와 대퇴부의 측정만으로도 전신체지방률을 추측 할 수 있게 되었다. 전신측정이 아닌 부분측정 값이 다른 검사방법으로 산출된 값과 비교하여 타당성을 갖는지 생체전기저항측정법(Bioelectrical Impedence Analysis, BIA)과 체질량 지수(Body Mass Index, BMI)와의 상관도 분석을 통해 알아보고자 한다. 2010년 3월부터 8월까지 본원 건강검진센터에 내원한 수검자 중 40세 이상의 여성 90명을 대상으로 DXA와 BIA를 통해 체지방률을 측정하였다. BMI는 신체 계측기를 통해 측정된 신장과 체중을 수검자 정보에 기입하여 자동으로 산출되는 값을 활용하였다. 또한 체중에 따른 차이가 있는지 알아보기 위해 BMI를 기준으로 저체중, 정상, 비만의 세 그룹으로 분류하여 각 그룹에서 BMI와 BIA, DXA 간의 상관도를 분석하였다. 저체중과 정상, 비만으로 나눈 세 그룹에서의 DXA와 BIA의 비교는 모든 그룹에서 통계적으로 유의한 차이를 보이지 않았다. 그룹으로 나누지 않은 상태에서의 상관분석결과 DXA로 측정된 체지방률은 BMI와 비교해 통계적으로 유의한 높은 상관관계를 나타냈으며(r=0.908, p<0.01) BIA와의 비교에서도 통계적으로 유의한 높은 상관관계를 보였다(r=0.927, p<0.01). 부분 골밀도 측정으로부터 추정된 전신체지방률이 BIA 그리고 BMI와 비교해 뛰어난 상관관계를 보여 정보의 신뢰도가 높다는 것을 확인하였다. 아직 추정된 전신체지방률에 관한 명확한 기준이 없어 골밀도측정만으로 체지방평가를 하기는 어렵다. 그러나 골밀도검사를 통해 골다공증의 진단은 물론 체지방에 관한 정보까지 얻을 수 있다는 점에서 매우 효율적이며 추후 전신골밀도검사로 측정된 체지방률과의 비교연구를 통해 더 객관적이고 임상적으로 유용한 정보 제공이 가능할 것으로 판단된다.

      • 간손상이 의심되는 간기능 검사 이상 환자의 치험례

        신현호(Hyun-ho Shin),최우준(Woo Jun Choi),김준철(Jun Chul Kim),나삼식(Sam sick Na),안훈모(Hun Mo Ahn) 대한의료기공학회 2009 醫療氣功 Vol.11 No.1

        Objective : The studies on liver effect in administration of western medicine have been well-established so far, but the studies on liver effect in administration or herbal medicine haven't been made. To make things worse, people who have liver disease generally believe that taking a herbal medicine is not useful to take care or their disease and even think it can cause liver disease. But this belief is not verified at all. So we feel the need to study about how taking herbal medicine affect to liver injury patient. Methods : We chose the 4 patient who seems to have the liver injury on the index of liver function test and we administrate the herbal medicine and after several day or weeks we recheck the liver function test. Results : Through the this method, we find the positive effect of taking herbal medicine on the patients who have the liver disease. Conclusions : Our results give no evidence that herbal medicine is harmful for liver disease. We need to study more about this.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼