Development of Water-Source Heat Pump System Using Riverbank Filtration Water on the Waterfront
조용(Cho, Yong),김대근(Kim, Dea Geun),문종필(Moon, Jong-Pil) 한국신재생에너지학회 2011 한국신재생에너지학회 학술대회논문집 Vol.2011 No.05
A water-source heat pump system has been developed for cooling and heating of a green house on the waterfront in Jinju. In order to supply a heat source/sink of water in alluvium aquifer to the heat pump system, the riverbank filtration facility (two pumping wells and one recharge well) for water intake and injection has been constructed. To pump and recharge water sufficiently, the geometric design such as depth and diameter for the wells have been completed, and details of the well such as slot size and length of the screen and filter pack size have been designed based on the practical and theoretical design method including D30 technique. For the investigation of the hydrogeological characteristics, step-drawdown test, long-term pumping test, and recovery test have been carried out for two developed pumping wells. Step-drawdown test has been performed on 4 step flowrates of 150, 300, 450, 600m³/day for 1 hour, and long-term pumping test on flowrate of 500m³/day for 24 hours, and recovery test for 6 hours. Since the underground water filtrated by riverbank is flowing smoothly into the well, the water level goes down slightly for the long-term test. Consequently, the stable pumping flowrate for two pumping well has been predicted at least over 1,647m³/day which is larger than the flowrate of 1,000m³/day for a 60 RT heat pump system.
조용(Cho, Yong),이동근(Lee, Dong Keun) 한국신재생에너지학회 2011 한국신재생에너지학회 학술대회논문집 Vol.2011 No.05
Performance of the raw water-source heat pump system with a thermal storage tank has been analyzed in winter season. The raw water is transferred through the multi-regional water supply system from Han river. Raw water is large temperature difference resource compared with groundwater. Although the raw water temperature drops to 0.6?C due to the heavy snowfall and the severe cold in late January and early February, 2010, the system has been normally operated without any trouble this winter. The unit COP and system COP considered all pump power consumption were estimated based on the second-by-second data of the all sensors. The monthly averaged unit COP and system COP are 3.37 and 2.76 respectively with 1.4?C of raw water in January, 3.55 and 2.89 with 1.6?C raw water in February, 3.82 and 3.15 with 5.4?C raw water in March. The performance of the system are increased with raw water temperature, and the COPs are higher than the water-to-air heat pump system using relatively high temperature raw water from Daecheong reservoir because the water-to-water system was operated on the full load condition and was stopped when the thermal storage tank was full of the high temperature water.