http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
반탄화 과정이 바이오매스 연료의 구조 및 연소성에 미치는 영향
정종원,김경민,야누아르 유디 이스워로,전충환,JEONG, JONG-WON,KIM, GYEONG-MIN,ISWORO, YANUAR YUDHI,JEON, CHUNG-HWAN 한국수소및신에너지학회 2018 한국수소 및 신에너지학회논문집 Vol.29 No.3
Torrefaction is one of the methods to increase combustion calorific value and hydrophobicity of biomass. In this study, the effects of torrefaction on devolatilization, char reactivity and biomass structure were analyzed. Empty fruit bunch (EFB) and Kenaf biomass were used as fuels to be torrefied in the N2 environment at 200, 250 and $290^{\circ}C$. Devolatilization and char kinetics were analyzed by using TGA and biomass structure was investigated through petrography image. The reactivity showed different trends depending on the torrefaction temperature and biomass structure. The herbaceous biomass, Kenaf, was shown as high reactivity and thin wall structure. On the contrary, the woody biomass, EFB, had relatively low reactivity and thick wall structure.
대퇴골두 골괴사증에서 시행한 인공 고관절 전치환술 -최소 10년 이상 추시-
정종원 ( Jong Won Chung ),박상원 ( Sang Won Park ),한승범 ( Seung Beom Han ),박종훈 ( Jong Hoon Park ),김호중 ( Ho Jung Kim ),이원석 ( Won Suck Lee ) 대한고관절학회 2010 Hip and Pelvis Vol.22 No.2
Purpose: The aim of this study was to assess the outcome of cementless total hip arthroplasty (THA) in cases of osteonecrosis of the femoral head. Materials and Methods: We studied long-term outcomes for 54 patients (72 hips). Mean duration of follow-up was 13.5 years. Clinical outcomes were evaluated by the Harris Hip Score. Radiographic evaluation from the preoperative and follow-up periods included assessment of the fixation of the femoral and acetabular components, polyethylene wear, osteolysis, and radiolucent line. Results: The mean Harris Hip Score improved from a preoperative value of 51.9 points to 89.4 at final follow-up. Regarding the femoral components, there was radiographic evidence of stable bony ingrowth in 69 hips, stable fibrous ingrowth in 2 hips and unstable fixation in 1 hip. There was a radiolucent line of less than 1 mm in 7 hips, and femoral osteolysis in 27 hips. Regarding the acetabular components, there was radiographic evidence of stable fixation in 68 hips, unstable fixation in 4 hips, and osteolysis in 39 hips. There was a significant correlation between (i) failure of components and (ii) femoral osteolysis, acetabular osteolysis, polyethylene thickness, linear wear rate per year, or total linear wear. Conclusion: The findings of this study show favorable long term results, both clinical and radiographic, using cementless total hip replacement arthroplasties. However, the revision rates for the Harris-Galante acetabular components were high. Wear of the load? weight? bearing surface continues to limit the long-term success rate of THA, and improved design of the acetabular components should be considered.
하이퍼큐브상의 오류회복기능을 갖는 메세지 전달 알고리즘
정종원(Chung Jong Won),공헌택(Kong heon Taek),우진운(Woo Jin Woon) 한국정보과학회 1994 한국정보과학회 학술발표논문집 Vol.21 No.1
하이퍼큐브 프로세서들의 커뮤니케이션은 상호 메세지 전달에 의하여 이루어진다. 프로세서들은 운영중 링크나 프로세서에 하드웨어 혹은 소프트웨어적인 결함을 가질수 있는데 신뢰성 높은 하이퍼큐브 시스템은 이러한 결함이 존재할 때도 메세지 전달을 계속 수행할 수 있어야 한다. 이러한 기능을 오류회복기능(Fault-tolerant)이라 한다. 본 연구에서는 깊이 우선 탐색과 독립된 경로를 이용하여 가능한 최단거리로 메세지를 전달하는 오류회복기능을 갖는 알고리즘을 제안하며, 시뮬레이션을 통하여 알고리즘의 성능을 비교, 평가한다.
건 유착 형성에 미치는 Polylactic Acid 흡수성 Film의 효용성
박상원(Sang Won Park),백종륜(Jong Ryoon Baek),이순혁(Soon Hyuck Lee),정종원(Jong Won Chung),조형준(Hyung Joon Cho) 대한정형외과학회 2006 대한정형외과학회지 Vol.41 No.1
목적: 건 봉합술 후 생기는 건의 유착 방지에 polylaetic acid 성분의 bioresorbable film이 유용한지 알아보고자 하였다. 대상 및 방법: 가토 24마리(48예)의 저113족지에서 심 족지 굴근을 절단하고 건을 봉합한 후 조작없이 건막을 봉합한 군을 제1군, 건과 건막 봉합 후에 건과 건막 사이에 hyaluronic acid를 주입한 군을 제2군, 건 봉합 후 film을 봉합건 주위에 피복 시킨 후 건막 봉합 술을 시행한 군을 제3군으로 나누어 수술 후 1주, 2주, 3주 및 6주에 조직학적 소견 및 생역학적 평가를 하였다. 결과: 광학 현미경 소견에서 섬유화의 정도는 제1군에서 가장 뚜렷하였고 제2군과 제3군에서는 큰 차이를 보이지 않았다. 만능 시험기를 통한 생역학적 검사상 모든 군에서 시간이 경과할수록 유착력(adhesion strength)은 증가하였다. 술 후 6주에는 제1군이 2군 및 3군에 비해 약 2.5-3배의 유착력을 나타냈고 통계적으로 유의성이 있었으며 제2군이 제3군에 비해 다소 높은 유착력을 나타냈으나 통계적으로 의미있는 차이는 보이지 않았다. 결론: 건 봉합 후 건이 치유됨에 따라 육아조직의 증식과 섬유화가 일어남을 확인하였고 polylactide resorbable film이건 봉합 후 건 유착 방지에 효과가 있었다. Purpose: To evaluate the effectiveness of a polylactic acid bioresorbable film in the prevention of tendon adhesion after tendon repair. Materials and Methods: Twenty-four adult rabbits (48 cases) were used in this study. In the first (control) group, the flexor tendons of the third toe were cut and a tenorrhaphy was performed. The 2nd group was injected with hyaluronic acid between the tendon and tendon sheath after suturing. The 3rd group underwent an enveloping of the tendon with polylactic acid film, followed by tenorrhaphy. The test animals were euthanized at 1, 2, 3, and 6 weeks after surgery, and the histology and biomechanics were evaluated. Results: Microscopic evaluations revealed fibrosis to be most apparent in group 1, while groups 2 and 3 showed no significant differences. The biomechanical tests, which were carried out using a Universal Testing Machine, revealed that an increase in adhesion strength with time. At 6 weeks after surgery, group 1 exhibited an adhesion strength that was 2.5-3 times greater than that exhibited by groups 2 and 3. Group 2 had a higher adhesion strength than group 3, but this difference was not statistically significant. Conclusion: Increases in granulation tissue and fibrosis during the healing of sutured tendons were observed, and the tested polylactide resorbable film was found to be effective in reducing the level of adhesion formation after tendon repair.
무시멘트형 Multilock 대퇴스템을 이용한 인공고관절 전치환술
박상원(Sang-Won Park),이순혁(Soon-Hyuck Lee),백종륜(Jong Ryoon Baek),정종원(Jong-Won Chung),최기원(Gi-Won Choi) 대한정형외과학회 2006 대한정형외과학회지 Vol.41 No.1
목적: 무시멘트형 Multilock 대퇴스템을 이용하여 인공고관절 전치환술을 시행하고 최소 10년 이상 추시 가능하였던 36명(44예)의 임상 및 방사선학적 결과를 후향적으로 분석하고자 하였다. 대상 및 방법: 1992년 1월부터 1994년 12월 사이에 환형성 무시멘트형 Multilock 대퇴스템과 Harris-Galante 제2형의 비구컵을 이용하여 인공고관절 전치환술을 시행한 44명(55예) 중 10년 이상 추시가 가능하였던 36명(44예)을 대상으로 하였다. 임상적 결과는 수술 전 및 최종 추시시의 Harris 고관절 점수를 측정하였다. 방사선학적 평가는 대퇴스템 주위의 방사선 투과선, 피질골비후, 대퇴거흡수, 골용해, Engh 등에 의한 대퇴스템의 고정도 등을 관찰하였다. 결과: 임상적 결과는 평균 Harris 고관절 점수는 수술 전 54.3점에서 최종 추시시 93.6점으로 39.3점 향상되었다. 방사선학 결과는 2 ㎜ 이하의 방사선 투과선 9예(20.5%), 골용해 13예(29.5%)였고, 최종 추시시 대퇴스템의 안정도는 골성고정 39예(88.6%), 섬유성 안정고정 2예(4.5%), 불안정고정 3예(6.8%)였다. 대퇴스템의 재치환술은 2예에서 시행하였고, 생존율은 불안정해리 3예(재치환술 2예 포함)를 제외한 41예(93.2%)였다. 결론: 환형성 무시멘트형 Multilock 대퇴스템을 이용한 인공고관절 전치환술은 10년 이상 추시시 임상적 및 방사선학적으로 우수한 결과를 나타냈으나 대퇴스템 주위(주로 1구역과 7구역) 골용해 발생은 비교적 높게 나타났으며 이에 대해서는 계속적인 관찰이 필요할 것으로 생각된다. Purpose: This study evaluated the minimum ten-year result of primary total hip arthroplasty with a non-cemented Multilock femoral stem. Materials and Methods: Fifty five total hip replacements in forty-four patients using a noncemented Multilock femoral stem and Harris-Galante 2 acetabular component were performed between January 1992 and December 1994. Forty-four hips in thirty-six patients were available for follow up for an average of eleven years (range, ten to twelve years). The clinical results were evaluated based on the Harris hip scores. A detailed radiography analysis was performed by an evaluation of the radiolucent lines, femoral osteolysis, and fixation stability by Engh Method. Results: The average Harris hip score improved from 54.3 points preoperatively to 93.6 points postoperatively. Non-progressive radiolucencies <2 ㎜ in width were observed in nine (20.5%), and femoral osteolysis was observed in thirteen cases (29.5%). For the fixation stability, osseous ingrowth was noted in thirty nine cases (88.6%) and fibrous ingrowth was observed in two (4.5%). There were three (6.8%) cases with unstable fixation. Two hips underwent revision. The survival rate of the femoral component was 93.2% (forty one cases) after a minimum ten-year follow up. Conclusion: The non-cemented Multilock femoral component provided excellent clinical and radiographic results. However, the rate of femoral osteolysis was relatively high (mostly restricted to zone 1 and 7).