RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Mandibular Kinesiograph 및 Myo-monitor 를 이용(利用)한 중심위(中心位), 중심교합(中心咬合), myo-co의 상호위치(相互位置) 및 자유로간격(自由路間隔)에 관(關)한 실험적연구(實驗的硏究)

        정재헌,Chung, Chae-Heon 대한치과보철학회 1980 대한치과보철학회지 Vol.18 No.1

        Recently, the controversy continues as to whether maximum intercuspation of teeth should occur at the terminal hinge position(the condylar theory) or at the myo-co(the neuromuscular theory). There is also much controversy regarding the antero-posterior position of myo-co. The object of this study was to measure and compare with the positional relations of centric relation, centric occlusion and myo-co, and free-way space using Mandibular Kinesiograph and Myo-monitor in the 40 subjects without stomatognathic problems. Mandibular Kinesiograph(M.K.G.) was originally conceived as a research instrument to track mandibular movement and position. As its use in research progressed, its great diagnostic value became apparent in case by case. And Myo-monitor was developed as a means of applying the neuromuscular approach to occlusion. Thus the Myo-monitor technique is an intra-systemic approach to occlusal positioning using patient's own musculature, and Myo-monitor is used to relax the musculature by a light myopulse induced electronically. From this experiment, the following results were obtained. 1. The adaptive free-way space before muscle relaxation was an average of $1.6{\pm}60mm$, and the true free-way space after muscle relaxation using Myo-monitor was an average of $2.4{\pm}0.74mm$. 2. It took an average of $25{\pm}3.11$ minutes to relax the mandibular musculature by Myo-monitor and administration of 5mg. Diazepam and an average of $38{\pm}4.73$ minutes by Myo-monitor without administration of Diazepam. 3. Myo-co existed anterior to centric occlusion, with an average of $0.53{\pm}0.31$ mm, and centric relation existed posterior to centric occlusion, with an average of $0.57{\pm}0.58mm$ before muscle relaxation and with an average of $0.57{\pm}0.43mm$ after muscle relaxation. 4. Centric relation coincided with centric occlusion in 5 of 40 subjects(12.5%), and posterior to centric occlusion in the rest of cases (87.5%). 5. Myo-co existed anterior to centric occlusion in 38 of 40 subjects(95%), except 1 subject that coincided with centric occlusion and 1 subject that existed posterior to centric occlusion. 6. Myo-co and centric relation existed inferior to centric occlusion and the lateral displacement was various with individual difference. 7. The total displacement from centric occlusion to centric relation was an average of $0.74{\pm}0.64mm$ before muscle relaxation, and an average of $0.68{\pm}0.53mm$ after muscle relaxation, and the total displacement from centric occlusion to myo-co was an average of $1.07{\pm}0.58mm$.

      • KCI등재

        나사 시멘트 유지형 임플란트 보철물의 잔여 전부하 및 시멘트 파손에 대한 임상평가

        정재헌,손미경,김석규,Chung, Chae-Heon,Son, Mee-Kyoung,Kim, Seok-Gyu 대한치과보철학회 2015 대한치과보철학회지 Vol.53 No.4

        목적: 이 연구의 목적은 지대주 나사 잔여 전부하 비율과 시멘트 파손유무 평가를 통해 나사 시멘트 유지형 임플란트 보철물(screw- and cement-retained implant prosthesis: SCP)의 임상적 수행 능력을 알아보는 것이다. 재료 및 방법: 구치부 부분 무치악 환자들을 대상으로 임플란트가 식립되었으며 3 - 6개월의 치유기간 후 SCP임플란트 보철물이 장착되었다. 추적관찰을 통해 임플란트의 생존율이 평가되고 보철물 성공률도 평가되었다. SCP 보철물의 나사 잔여 전부하 비율 및 시멘트 파손 비율이 측정되었다. 결과: 20명의 환자로부터 21개의 SCP보철물(43개의 임플란트)이 최대 64개월까지 관찰되었다. 관찰기간(평균 34개월) 동안 골융합에 실패한 임플란트는 하나도 없었다. 지대주, 나사, 도재 혹은 보철물 프레임 파절이나 나사 풀림 등은 없었으므로 보철물 성공율은 100%였다. SCP 보철물의 나사 잔여 전부하 비율은 97.61% (${\pm}16.29$), 그리고 시멘트 파손비율은 9.5%이었다. 결론: 본 실험의 한계 내에서, 나사 풀림과 시멘트 파손이란 관점에서 SCP 디자인의 임플란트 보철물은 양호한 단기 임상 결과를 보였다. Purpose: The aim of this study was to evaluate the clinical performance of screw- and cement-retained implant prosthesis (SCP) design in terms of retained preload of abutment screws and cement washout. Materials and methods: Patients with the partial posterior edentulous areas comprised the study group. Implants were placed, and SCPs were delivered after 3 to 6 months healing. Follow-up examinations were performed. The implant survival rate and the prosthetic success rate were evaluated. The retained preload ratio of abutment screws and the prosthetic decementation ratio were measured. Results: Twenty one SCPs (forty three implants)in twenty patients were followed up to 64 months. All of the implants survived during the follow-up period (mean follow-up: 34 months). The prosthetic success rate was 100 % considering no abutment, screw, porcelain or metal frame fractures, as well as no screw loosening. The retained preload ratio of SCPs at the end of follow-up period was 97.61% (${\pm}16.29$) and the decementation ratio was 9.5 %. Conclusion: Within the limitations of this clinical study, SCP design showed favorable short-term clinical performances in respect of screw loosening and cement washout.

      • KCI등재

        골내 임플랜트의 종류에 따른 광탄성 응력 분석

        정재헌,장두익,Chung Chae-Heon,Chang Doo-Ik 대한치과보철학회 1993 대한치과보철학회지 Vol.31 No.4

        The purpose of this study was to analyze the stress distribution at supporting bone according to the types of endosseous implants. This investigation evaluated the stress patterns in rectangular photoelastic models produced by four different types of dental implants such as $Br\ddot{a}nemark$, screw type of Steri-Oss, blade type of Steri-Oss, IMZ with IMC and resin tooth using the techniques of quasi-three dimensional photoelasticity. All prostheses were casted in the same nonprecious alloy and were cemented or screwed on their respective implants and abutments. 20 kg of vertical load was applied on the central fossa of casted crown and 16 kg of inclined had was applied on the top third of distal surface of casted crown respectively. The results were as follows : 1. Under the vertical load, screw implants of Steri-Oss and $Br\ddot{a}nemark$ showed increasing stress condition between and around the screw threads along the implant lateral surface and cylindrical implant of IMZ showed the less stress condition along the lateral surface with concentration of stress mostly near the root apex. 2. Under the vertical load, the stress of Steri-Oss blade was distributed uniformly at the alveolar bone under the broad blade. 3. Under the inclined load, the stress concentration of Steri-Oss screw and $Br\ddot{a}nemark$ was developed highly around the mesiocervical bone area on the contralateral side to force application. The stress of $Br\ddot{a}nemark$ with flexible gold glod was more concentrated in the cervical bone area than that of Steri-Oss with stiff screw. 4. Under the inclined load, the stress of Steri-Oss blade broadly was distributed around the mesioceivical bone area and the lower and mesial bone area of the blade. 5. Under the Inclined load, IMZ implant showed the gap between c개wn and fixture due ta deformation of the IMC and IMZ was lower in stress concentration developed around the mesiocervical bone area than $Br\ddot{a}nemark$ and Steri-Oss screw. 6. Under the inclined load, the stress magnitude induced in the mesiocervical bone area of implants was in order of $Br\ddot{a}nemark$, Steri-Oss strew, IMZ and Stsri-Oss blade. 7. Tilting forces as compared to axial forces exerted greater magnitude of stress in the cervical bone area of the implant. 8. In respect of stress distribution, Steri-Oss blade was superior than any other implants and in respect of the stability by horizontal lone, IMB and $Br\ddot{a}nemark$ was inferior than any other implants.

      • KCI등재

        FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES AND DENTURE MOVEMENTS INDUCED BY VARIOUS DENTURE BASE MATERIALS

        정재헌,윤창근,Chung, Chae-Heon,Yoon, Chang-Keun The Korean Academy of Prosthodonitics 1987 대한치과보철학회지 Vol.25 No.1

        의치상 재료 종류에 따라 의치, 점막 및 하악골에 발생되는 변위 및 응력을 연구하기 위하여 컴퓨터를 이용한 수치적 해석인 2차원 유한 요소법을 이용하였다. 2차원 유한 요소 모형으로선 표준 크기의 하악골 및 의치를 고려하여 231개의 사변형 요소 및 268개의 절점으로 분할한 후 각 구성 성분의 물리적 성질인 탄성률 및 프와송비를 대입시켰다. 사용된 의치로서는 일반 합성수지의치, 2mm후경의 탄성재를 의치상 하부에 이장한 합성수지의치, 2mm후경의 탄성재를 치아와 의치상 중앙에 삽입한 합성수지의치 및 0.5mm후경의 금속상의치의 4종류였으며, 하중시에 하악의 고정 부위로선 생체와 동일 조건을 부여하기 위하여 교근, 내측익돌근, 측두근등의 하악 폐구근이 부착되는 하악각 부위 및 하악 근돌기 부위의 16절점을 고정점으로 하였다. 하중 조건으로선 하악 제1대구치의 일점에 10kg의 수직 집중하중, 하악 중절치의 일점에 7kg의 수직 집중하중 및 하악 제 1소구치로 부터 하악 제2대구치까지의 교합면에 10kg의 수직 분산하중을 부여하여 분석한 결과는 다음과 같다. 1. 하중이 의치 교합면위의 가해진 부위에 따라 다양한 의치 회전 및 강하 현상을 보였으며, 탄성재를 이장 및 삽입한 합성 수지 의치의 변위가 일반 합성수지의치 및 금속상 의치의 변위보다 더 컸다. 2. 주응력을 고려할때 점막 부위에는 주로 압축 응력이 작용하였으며 치조제 부위는 압축응력과 인장 응력이 함께 작용하였다. 3. 탄성재를 삽입한 합성수지의치에 최고 등가 응력이 집중되었으며 그 다음은 탄성재를 이장한 합성수지의치, 일반 합성수지의치의 순이였으며 금속상의 경우는 금속을 따라서 높은 등가 응력이 넓게 분산되었다. 4. 의치상 종류에 관계없이 동일 하중 조건하에선 점막에 나타나는 등가 응력의 크기 및 분산양태는 유사하였다. 5. 하악골에서 등가 응력은 의치지지 부위에만 국한되지 않고 넓게 분산 되었으며 의치상 종류 및 하중 조건에 관계없이 치조제 후방 및 하악연의 후방 부위에 특히 높은 등가응력이 집중되었다. 6. 하악 중절치의 일점에 수직 하중을 가한 경우가 다른 하중 조건에 비하여 지지점과의 거리차이로 인하여 하악골에 가장 높은 등가 응력을 유발하였다. 7. 의치상 재료에 따른 하악 골에 발생되는 응력의 크기 및 분산에는 큰 차이가 없으나 금속상의 경우가 교합압을 분산하는데는 효과적이었다.

      • KCI등재

        수종의 탄성 의치상 이장재에 대한 Candida albicans의 성장에 관한 연구

        정재헌,김광원,김동기,이장희,Chung, Chae-Heon,Kim, Kwang-Won,Kim, Dong-Ki,Lee, Zang-Hee 대한치과보철학회 1993 대한치과보철학회지 Vol.31 No.1

        For the purpose of this study was to determine the growth of Candide albicans on the surface of the resilient denture liners. The discs$(40\times40mm)$ of 2 resilient lining materals (Molloplast B, Mollosil) and one conventional acrylic resin (K-33) and one metal plate were processed and disinfected. Firstly, the test discs were placed into petri dish, and Candide albicans suspensions was overlayed on the test discs. And the test discs were incubated with intermitant shaking for 1 hour, 2 hours, 6 hours, 12 hours, 24 hours. After incubation, imprint culture method was achived and counted the colony on the agar plate. Secondly, the effect of denture cleansing agents on the growth of Candide alibicans on the resilient dentureliners was evaluated. The results were as follows : 1. The growth of Candida albicans on discs of Molloplast B and Mollosil was increased than that on discs of acrylic resin and metal plate (p<0.05). 2. As Candide albicans suspensions were incubated for 2 hours, the growth of Candida albicans on discs of Mollosil was increased than that on discs of Molloplast B (p<0.05), and the growth of Candide albicans on discs of metal plate was increased than that on discs of acrylic resin (p<0.05). 3. As Candide albicans suspensions were incubated for 6 hours, the growth of Candide albicans on discs of Mollosil was increased than that on discs of Molloplast B (p<0.05). 4. The growth of Candide albicans on discs of Mollosil and Molloplast B in treating denture cleansing agent was inhibited than control discs (p<0.05).

      • KCI등재
      • KCI등재
      • KCI등재
      • KCI등재
      • KCI등재

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼