RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        반응표면 분석법을 이용한 천연마섬유보강 순환굵은골재 콘크리트의 성능 평가

        전지홍,김황희,김춘수,유성열,박찬기,Jeon, Ji Hong,Kim, Hwang Hee,Kim, Chun Soo,Yoo, Sung Yeol,Park, Chan Gi 한국농공학회 2014 한국농공학회논문집 Vol.56 No.4

        In this study, evaluated ware the strength and durability of the vegetated water purification channel concrete to which recycled aggregates, hawang-toh and jute were applied. Box-Behnken method of response surface analysis in statistics was applied to the experimental design. Experimental variables are as follows, recycled coarse aggregates, hawang-toh, blast-furnace slag and jute fiber. In the experiment, conducted were the tests of compressive strength, chloride ion penetration, abrasion resistance and impact resistance the replacement rate effects of the recycled aggregates, blast-furnace slag and hwang-toh on the performance of vegetated water purification channel concrete were analyzed by using the response surface analysis method on the basis of the experimental results. In addition, an optimum mixing ratio of vegetated water purification channel concrete was determined by using the experimental results. The optimum mixing ratio was determined to be in 10.0% recycled coarse aggregates, 60.0% blast-furnace slag, 10.1% hwang-toh and 0.16% jute fiber. The compressive strength, chloride ion penetration, abrasion rate, and impact number of fracture test results of the optimum mixing ratio were 24.1 MPa, 999 coulombs, 10.30 g/mm3, and 20 number, respectively.

      • KCI등재

        L-THIA를 이용한 서울특별시 유출량 공간적 분석: 2011년 7월 27일 강우를 중심으로

        전지홍,Jeon, Ji-Hong 한국농공학회 2011 한국농공학회논문집 Vol.53 No.6

        Temporal and spatical surface runoff by heavy rainfall during 25~28 July, 2011 causing urban flooding at Seoul were analyzed using Long-Term Hydrologic Impact Assessment (L-THIA). L-THIA was calibrated for 1988~1997 and validated for 1998~2007 using monthly observed data at Hangangseoul watershed which covers 90 % of Seoul city. As a results of calibration and validation of L-THIA at Hangangseoul watershed, Nash-Sutcliffe coefficients were 0.99 for calibration and 0.99 for validation. The simulated values were good agreement with observed data and both calibrated and validated levels were "very good" based on calibration criteria. The calibrated curve number (CN) values of residential and other urban area represented 87 % and 93 % of impervious area, respectively, which were maximum percentage of impervious area. As a result of L-THIA application at Seoul city during 25~28 July, 2011, most of rainfall (54 %, 287.49 mm) and surface runoff (65 %, 247.32) were generated at 27 July, 2011 and a significant amount of rainfall and surface runoff were occurred at southeastern Seoul city. As a result of bi-hourly spatial and temporal analysis during 27 July, 2011, surface runoff during 2:00~4:00 and 8:00~10:00 were much higher than those during other times and surface runoff located at Seocho-gu during 6:00~8:00 represented maximum value with maximum rainfall intensity which caused landslide from Umyun mountain.

      • KCI등재

        논에서의 비점오염부하 예측을 위한 엑셀기반의 PADDIMOD2 개발

        전지홍,Jeon, Ji-Hong 한국농공학회 2011 한국농공학회논문집 Vol.53 No.4

        PADDIMOD2 was deloped to estimate nonpoint source pollution from paddy rice fields. The PADDIMOD2 was enhanced to estimate runoff and pollutant load during non-growing as well as growing season and to be easily used for public by development of Excel based system. Nutrient concentration and hydrology were based on Dirac delta function and continuous source function, and tank model for growing season and Event Mean Concentrations (EMCs) and SCS-Curve Number method for non-growing season. The PADDIMOD2 consists of three main component (input data, parameters data, and output data) by including eight Excel spread sheets. As a result of model application, total precipitation and irrigation were 1,051.7 mm and 439.2 mm, respectivley and surface runoff and water loss including infiltration and evapotranspiration were 463.0 mm and 947.9 mm, respectively. Annual nutrient loadings of T-N and T-P from study area were 6.7 kg/$km^2$/day and 0.5 kg/$km^2$/day, respectively. Development of PADDIMOD2 was focused on minimizing input data and maximizing user friendly system and is expected to be useful tool to evaluate various non-structure BMPs and estimate unit load from paddy rice fields for application at Korean TMDL.

      • KCI등재

        최적화 기법을 이용한 임하호유역 대표 CN값 추정

        전지홍,김태동,최동혁,Jeon, Ji-Hong,Kim, Tae-Dong,Choi, Dong-Hyuk 한국농공학회 2011 한국농공학회논문집 Vol.53 No.5

        Curve Numbers (CN) for the combination of land use and hydrologic soil group were regionalized at Imha Watershed using Long-term Hydrologic Impact Assessment (L-THIA) coupled with SCE-UA. The L-THIA was calibrated during 1991-2000 and validated during 2001-2007 using monthly observed direct runoff data. The Nash-Sutcliffe (NS) coefficients for calibration and validation were 0.91 and 0.93, respectively, and showed high model efficiency. Based on the criteria of model calibration, both calibration and validation represented 'very good' fit with observe data. The spatial distribution of direct surface runoff by L-THIA represented runoff from Thiessen pologen at Subi and Sukbo rain gage station much higher than other area due to the combination of poor hydrologic condition (hydrologic soil C and D group) and locality heavy rainfall. As a results of hydrologic condition and treatment for land use type based on calibrated CNs, forest is recommended to be hydrologically modelled dived into deciduous, coniferous, and mixed forest due to the hydrological difference. The CNs for forest and upland showed the poor hydrologic condition. The steep slope of forest and alpine agricultural field make high runoff rate which is the poor hydrologic condition because CN method can not consider field slope. L-THIA linded with SCE-UA could generated a regionalized CNs for land use type with minimized time and effort, and maximized model's accuracy.

      • KCI등재

        HSPF-PEST를 이용한 불연속 실측치 자동보정

        전지홍,이새봄,Jeon, Ji-Hong,Lee, Sae-Bom 한국농공학회 2012 한국농공학회논문집 Vol.54 No.6

        Applicability of 8 day interval flow data for the calibration of hydrologic model was evaluated using Hydrological Simulation Program-Fortran (HSPF) at Kyungan watershed. The 8 day interval flow monitored by Ministry of Environment located at upstream was calibrated and periodically validated during 2004-2008. And continuous daily flow monitored by Ministry of Construction & Transportation (MOCT) and located at the mouth was compared with daily simulated data during 2004-2007 as spatial validation. Automatic calibration tool which is Model-Independent Parameter Estimation & Uncertainty Analysis (PEST) was applied for HSPF calibration procedure. The model efficiencies for calibration and periodic validation were 0.63 and 0.88, and model performances were fair and very good, respectively, based on criteria of calibration tolerances. Continuous daily stream flow at the mouth of Kyungan watershed were good agreement with observed continuous daily stream flow with showing 0.63 NS value. The PEST program is very useful tool for HSPF hydrologic calibration using non-continuous daily stream flow as well as continuous daily stream flow. The 8 day interval flow data monitored by MOE could be used to calibrate hydrologic model if the continuous daily stream flow is unavailable.

      • KCI등재

        소유역 유달율 추정공식 개발 -보청A유역을 중심으로-

        전지홍,최동혁,임경재,김태동,Jeon, Ji-Hong,Choi, Dong-Hyuk,Lim, Kyung-Jae,Kim, Tae-Dong 한국농공학회 2010 한국농공학회논문집 Vol.52 No.5

        The characteristics of delivered nutrient loads were analyzed and the regression equations to estimate delivery ratios of nutrients (TN and TP) were developed using HSPF simulation results at six subwatersheds within the Bochung A unit watershed during 1998-2007. TN delivery ratio was higher than TP delivery ratio because significant amounts of TP was considered to be attached at soil as ${PO_4}^-$ during delivery process from discharged point of nutrient source to main stream. As a results of correlation analysis, factors related to geomorphic characteristics had not statistical correlation with TN and TP delivery ratios. TN loading rate from living and specific stream flow had statistical negative and positive correlation, respectively, with TN delivery ratio. TP loading rates from all sources and from land cover and specific stream flow had statistical negative, negative and positive correlation, respectively. The specific stream flow represents the most strong correlation with nutrient delivery ratios. The regression equations to estimate delivery ratios for TN and TP were developed by including statistical correlated factors and showed high efficiency of 0.98 and 0.95 of coefficient of determination for TN and TP, respectively.

      • KCI등재

        HSPF를 이용한 임하호 유역 유사량 모의

        전지홍,Jeon, Ji-Hong 한국농공학회 2010 한국농공학회논문집 Vol.52 No.6

        Sediment yields from Imha watershed were simulated during 1993-2008 using Hydrologic Simulation Program-Fortran (HSPF). Using observed daily stream flow for 2004-2008 and hourly suspended solid concentration for three events during 2006, HSPF was calibrated and validated at the sites of Imha and Youngyang for stream flow and Dongchun and Jangpachun for sediment yield. The calibration and validation results represented high model efficiency for simulating daily stream flow and hourly suspended solid. The determination coefficients of calibration and validation were 0.90 and 0.81 for daily stream flow, and 0.91 and 0.86 for monthly stream flow, respectively. Based on model tolerances for calibration and validation of stream flow, HSPF performance for simulating stream flow represented 'very good'. The determination coefficients of calibration and validation were 0.94-0.96 and 0.95 for hourly sediment yields, respectively. The average yearly sediment yield during 1993-2008 was 122,290 ton/year and most of sediment yield (77 % of total yield) were generated from June to August. The calibrated HSPF simulated well the movement of water and eroded soil within Imha watershed.

      • KCI등재

        보청A유역 유량 및 영양물질 자동보정을 위한 HSPF-PEST 연계적용

        전지홍,최동혁,임경재,김태동,Jeon, Ji-Hong,Choi, Dong-Hyuk,Lim, Kyung-Jae,Kim, Tae-Dong 한국농공학회 2010 한국농공학회논문집 Vol.52 No.5

        Hydrologic Simulation Program-Fortran (HSPF) coupled with PEST which is optimization program was calibrated and validated at Bochung watershed by using monitoring data of water quantities and nutrient loading. Although the calibrated data were limited, model parameters of each land use type were optimized and coefficient of determinations were ranged from 0.94 to 0.99 for runoff, from 0.89 to 1.00 for TN loading, and from 0.92 to 1.00 for TP loading. The optimized hydrological parameters indicated that the forested land could retain rainfall within soil layer with high soil layer depth and infiltration rate compared with other land use type. Hydrological characteristics of paddy rice field are low infiltration rate and coefficient of roughness. The calibrated parameters related to nutrient loading indicated generation of nutrient pollution from agricultural area including upland and paddy rice field higher than other land use type resulting from fertilizer application. Overall PEST program is useful tool to calibrate HSPF automatically without consuming time and efforts.

      • KCI등재

        L-THIA를 이용한 낙동강수계 임하댐유역 비점오염원의 공간적 분포해석

        전지홍,다니엘차,최동혁,김태동,Jeon, Ji-Hong,Cha, Daniel K.,Choi, Donghyuk,Kim, Tae-Dong 한국농공학회 2013 한국농공학회논문집 Vol.55 No.1

        Long-Term Hydrologic Impact Assessment (L-THIA) model which is a distributed watershed model was applied to analyze the spatial distribution of surface runoff and nonpoint source pollutant loading from Imha watershed during 2001~2010. L-THIA CN Calibration Tool linked with SCE-UA was developed to calibrate surface runoff automatically. Calibration (2001~2005) and validation (2006~2010) of monthly surface runoff were represented as 'very good' model performance showing 0.91 for calibration and 0.89 for validation as Nash-Sutcliffe (NS) values. Average annual surface runoff from Imha watershed was 218.4 mm and Banbyun subwatershed was much more than other watersheds due to poor hydrologic condition. Average annual nonpoint source pollutant loading from Imha wateshed were 2,295 ton/year for $BOD_5$, 14,752 ton/year for SS, 358 ton/year for T-N, and 79 ton/year for T-P. Amount of pollutant loading and pollutant loading rates from Banbyun watershed were much higher than other watersheds. As results of analysis of loading rate from grid size ($30m{\times}30m$), most of high 10 % of loading rate were generated from upland. Therefore, major hot spot area to manage nonpoint source pollution in Imha watershed is the combination of upland and Banbyun subwatershed. L-THIA model is easy to use and prepare input file and useful tool to manage nonpoint source pollution at screening level.

      • KCI등재후보

        농업용 저수지의 물리적 인자가 수질에 미치는 영향

        전지홍(Ji Hong Jeon),윤춘경(Chun Gyeong Yoon),함종화(Jong Hwa Ham),김호일(Ho Il Kim),황순진(Soon Jin Hwang) 한국하천호수학회 2002 생태와 환경 Vol.35 No.1

        The effect of physical parameters on water quality was analyzed using monitoring data of 193 agricultural reservoirs. The retention time of reservoirs(t_d) ranged between 10 and 140 days, and the ratio of drainage area(DA) to reservoir surface area(SA) was between 10 and 120. Both ratios of DA/SA and total area(TA)/ reservoir storage(ST) in Korean agricultural reservoirs were relatively greater than those in natural lakes in other countries. As retention time was plotted against DA/SA ratio, it was shorter in Korean reservoirs than natural lakes. The semi-logarithmic relationship between TA/SA and t_d was t_d = 42.21(TA/ST)^-1 (n = 50, R^2 = 0.89). While areal loading of total phosphorus(TP) was below 4 gTP·m^-2·yr^-2 in general, it exceeded 10 gTP·m^-2·yr^-1 in reservoirs where DA/SA ratio was greater than 100, which implies that areal loading of TP increases as DA/SA ratio increases. Chl-a concentration was positively related with the mean depth of reservoir, implying the higher Chl-a concentration with deeper the mean depth. Therefore, the deeper reservoir might be advantageous in water quality management perspective if other morphological conditions are similar. The empirical regression equation using physical parameters was also suggested in the estimation of TP concentration in the reservoirs. Combined information presented in this paper might be applicable to the water quality management in agricultural reservoirs.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼