박국남(K.N. PARK),박종학(J.H. PARK),이정영(C.Y. LEE),김학노(H.R. KIM),유성연(S.Y. YOO) 한국유체기계학회 2006 유체기계 연구개발 발표회 논문집 Vol.- No.-
The Fuel Test Loop(FTL) has been developed for the irradiation test of nuclear fuels. The FTL provides the test conditions similar to the operation conditions of the PWR and CANDU nuclear plants. The FTL consists of In-Pile Test Section(IPS) and Out-of-Pile System(OPS). The IVA(IPS Vessel Assembly) could be divided into an external assembly and an interior assembly from a total assembly. IVA is to dual pressure vessel which nuclear fuel is assembled on interior. For a domestic production characteristic confirmation and a design verification IVA mock-up it produced. IVA mock-up where it is produced were used in vibration test and differential pressure test. In order to verify the pressure-drop prediction in the IVA, a series of pressure-drop test has been carried out by using the IVA mock-up. As a result of the experiment, it is found that the measured pressure drop shows a good agreement with the calculated pressure drop.