RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        강화형 치관용 복합레진의 인장강도에 관한 연구

        안승근,강동완,Ahn, Seung-Geun,Kang, Dong-Wan 대한치과보철학회 2000 대한치과보철학회지 Vol.38 No.2

        Recently a new generation of crown and bridge veneering resins containing submicron glass fillers was introduced. These ultrasmall particle hybrid composite materials distinguish themselves, compared with conventional microfill crown and bridge resins, through improved mechanical properties. It is claimed that these composites are suitable for metal free crowns and even bridges using fiber reinforcement. The purpose of this study was to evaluate the effect of thermal cycling on the tensile strength of the following veneering composites: Artglass(Heraeus Kulzer Co., Wehrheim, Germany), Estonia(Kuraray Co.. Japan), Sculpture(Jeneric Pentron Co., Wallingford, U.S.A.), and Targis(Ivoclar Co., Schaan Liechenstein). According to manufacturer's instructions, rectangular tensile test specimens measuring $1.5{\times}2.0{\times}4.5mm$ were made using a teflon mold. Whole specimens were divided into two groups. One group was dried in a desiccator at $25^{\circ}C$ for 10 days, and another group was subjected to thermal cycling($10,000{\times}$) in water($5/55^{\circ}C$). All test specimens were placed in a universal testing machine and loaded until fracture with a crosshead speed of 0.5mm/min. Weibull analysis and Tukey's test were used to analyze the data. The fracture surfaces of specimens were observed in SEM and the aliphatic C=C absorbance peak of Estenia and Targis resin was analyzed using Fourier transform infrared(FTIR) spectroscopy. Within the limitations imposed in this study, the following conclusions can be drawn: 1. Both in drying condition and thermal cycling condition, the highest tensile strength was observed in Estenia testing group(p<0.05). 2. The strength data were at to single-mode Weibull distribution, and the Weibull modulus of all veneering composite resin specimens increased after thermal cycling treatment. 3. After thermal cycling test, the highest tensile strength was observed in the Estenia group, and the lowest value was observed in the Targis group. The tensile strength values showed the significant differences between each group(p<0.05) 4. The aliphatic C=C absorbance peak of Estonia and Targis resin was decreased after light curing, and there was no distinct change after thermal cycling.

      • KCI등재

        압자압입법에 의한 치과용 도재의 파괴인성 평가

        안승근,이주형,배태성,Ahn, Seung-Geun,Lee, Ju-Hyung,Bae, Tae-Sung 대한치과보철학회 1996 대한치과보철학회지 Vol.34 No.2

        This study was performed to evaluate the fracture toughness of seven commercially available dental ceramics by indentation fracture method. All specimens were fabricated to the final dimensions of approximately 12mm in diameter 2mm in thickness. The characte-ristic indentation dimensions of Vickers or Knoop indentation were measured to calculate the fracture toughness values and Young’s moduli. The results obtained were summarized as follows; 1. Young’s modulus and Vickers hardness of Vita In-Ceram showed the maximum values of $154.4{\pm}49.2$ Gpa and $12.60{\pm}0.71$Gpa, respectively. Results of Scheff test exhibited the significant difference between Vita In-Ceram group and others(p<0.01). 2. Maximum fracture toughness of $2.562{\pm}0.37 MPam^{1/2}$ for Vita In-Ceram and the maxi-mum one of $0.908{\pm}0.132MPam^{1/2}$ for Vitadur-N were calculated. Results of Scheff test showed the significant difference between Vita In-Ceram group and Vita Hi-Ceram(p<0.05) : also between Vita In-Ceram or Vita Hi-Ceram and others(p<0.01). 3. The alumina-based core ceramics showed the aspect of Palmqvist crack for the indentation load of 49.0N, but others showed the median/lateral crack for the indentation load of 9.8N.

      • KCI등재

        하악 전치부의 개폐운동과 안정위에 관한 연구

        안승근,송광엽,박찬운,Ahn, Seung-Geun,Song, Kwang-Yeob,Park, Charn-Woon 대한치과보철학회 1989 대한치과보철학회지 Vol.27 No.2

        The purpose of this study was to investigate the mandibular opening and closing movements at mandibular incisor region and clinical rest position in normal subject using the newly developed electric mandibular movement analyzing device, (M.K.G.-K6 diagnostic system, Myo-tronics Inc. Seattle, WA, U.S.A.) The 58 normal subjects, who were students of the College of Dentistry, Chonbuk National University, were selected according to sampling criteria. The obtained results were as follows: 1. There was no significant difference of distribution of opening and closing movement patterns at mandibular incisor region between male and female. There was significant difference between habitual and maximum movement patterns both in sagittal and frontal plane. 2. Although the percentage of distribution of crossover pattern was highest in all cases, but there were significant differences between patterns only at habitual opening and closing movement in sagittal plane. 3. The mean of maximum opening was $47.29{\pm}4.68mm$ in male and $42.15{\pm}4.95mm$ in female. Therefore the mean of maximum opening was larger in male than in female. 4. The mean of maximum laterotrusion in frontal trajectory was larger to the left than to the right. Also the proportion of left deviation at maximum opening position was larger than that of other cases. 5. The mean of maximum opening and closing velocity was higher in male than in female and the mean of closing velocity was higher than that of opening velocity. Also the amount of separation from the centric occlusion was higher in maximum closing velocity than in maximum opening velocity. 6. Clinical rest position was $1.70{\pm}0.99mm$ inferior, $0.74{\pm}0.57mm$ anterior, $0.99{\pm}0.51mm$ right from centric occlusion and the A/V ratio was 1:2.7.

      • KCI등재
      • KCI등재
      • KCI등재
      • KCI등재
      • KCI등재

        화학적 처리가 티타늄의 생체활성도에 미치는 영향

        민관식,이민호,안승근,박찬운,Min Kwan-Sik,Lee Min-Ho,Ahn Seung-Geun,Park Charn-Woon 대한치과보철학회 2005 대한치과보철학회지 Vol.43 No.4

        Statement of problem : Titanium is widely used as an implant material lot artificial teeth. Also, studies on surface treatment to form a fine passive film on the surface of commercial titanium or its alloys and improving bioactivity with bone have been carried out. However, there is insufficient data about the biocompatibility of the implant materials in the body. Purpose: The purpose of this study was to examine whether the precipitation of apatite on titanium metal is affected by surface modification. Materials and methods: Specimens chemically washed for 2 minute in a 1:1:1.5 (in vol%) mixture of 48% HF 60% $HNO_3$ and distilled water. Specimens were then chemically treated with a solution containing 97% $H_2SO_4$ and 30% $H_2O_2$ at $40^{\circ}C$S for 1 hour, and subsequently heat-treated at $400^{\circ}C$ for 1 hour. All specimens were immersed in the HBSS with pH 7.4 at $36.5^{\circ}C$ for 15 days, and the surface were examined with TF-XRD, SEM, EDX and XPS. Also, commercial purity Ti specimens with and without surface treatment were implanted in the abdominal connective tissue of mice for 4 weeks. Conventional aluminium and stainless steel 316L were also implanted for comparison. Results and conclusions : The results obtained were summarized as follows. 1. An amorphous titania gel layer was formed on the titanium surface after the titanium specimen was treated with a $H_2SO_4$ and $H_2O_2$ solution. The average roughness was $2.175{\mu}m$ after chemical surface treatment. 2. The amorphous titania was subsequently transformed into anatase by heat treatment at $400^{\circ}C$ for 1 hour. 3. The average thickness of the fibrous capsule surrounding the specimens implanted in the connective tissue was $46.98{\mu}m$ in chemically-treated Ti, and 52.20, 168.65 and $100.95{\mu}m$ respectively in commercial pure Ti, aluminum and stainless steel 316L without any treatment.

      • KCI등재

        Strategic serial extractions and immediate implantation for interdental papilla preservation: A case report

        최근배,이정진,안승근,서재민,Choi, Geun-Bae,Lee, Jung-Jin,Ahn, Seung-Geun,Seo, Jae-Min The Korean Academy of Prosthodonitics 2017 대한치과보철학회지 Vol.55 No.3

        치간유두의 보존을 위해서는 치간골의 혈액공급이 매우 중요하다. 인접한 임플란트 사이의 치간유두를 재생하는 것은 치아와 임플란트 사이의 치간유두보다 어렵다. 그러므로 인접한 임플란트를 식립할 경우 임플란트 사이 조직을 보존하는 것이 필요하다. 이를 위해서 전략적 발치술, 즉시 임플란트 식립 및 임시 보철물 제작은 임플란트 주위 조직을 보존하는데 효과적인 방법으로 소개되었다. 본 증례는 손상된 양측 상악 중절치를 전략적 연속 발치술 및 임플란트 즉시 식립을 통해 회복한 환자로 24개월 뒤 임플란트 주위 조직 및 치간 유두가 안정적으로 보존되었기에 이를 보고하는 바이다. Maintaining the blood supply of the interdental alveolar bone is crucial for preserving the interdental papilla. Rebuilding the interimplant papilla between adjacent implants is more difficult than rebuilding the interdental papilla between the natural tooth and implant. Therefore, preserving the interimplant tissue is necessary when adjacent implants are closely placed. In this case report, three effective methods for maintaining the surrounding tissue, namely strategic serial extraction, immediate implantation, and provisionalization of adjacent maxillary central incisors, were performed. The marginal gingiva and interimplant papilla were well maintained for 24 months.

      • KCI등재

        지르코니아 세라믹의 표면처리에 따른 치과용 접착제의 전단결합강도

        김지혜,서재민,안승근,박주미,송광엽,Kim, Ji-Hye,Seo, Jae-Min,Ahn, Seung-Geun,Park, Ju-Mi,Song, Kwang-Yeob 대한치과보철학회 2013 대한치과보철학회지 Vol.51 No.2

        연구 목적: 이 연구의 목적은 지르코니아 표면처리에 따른 3종의 레진시멘트와 지르코니아의 전단결합강도를 평가하기 위함이다. 연구 재료 및 방법: 총 143개의 디스크 모양의 지르코니아 블록(HASS Co., Gangneung, Korea) 시편을 제작하고 총 13개군(n=11)으로 나누었다. 그중9개군은 표면처리 방식(1. 알루미나 분사, 2. 알루미나 분사와 지르코니아 라이너의 도포, 3.알루미나 분사와 Rocatec (3M ESPE, Seefeld, Germany) 처리) 및 사용한 3종류의 레진시멘트(Bistite II (Tokuyama Dental Co., Japan), Panavia F2.0 (Kuraray Medical, Japan), Super-bond C&B (Sun Medical, Japan))에 따라 나누어 열순환처리 전 접착강도 실험을 시행하였다. 열순환처리 전 접착강도 실험은 위 3종류의 레진시멘트를 3가지 방법으로 표면처리한 지르코니아 시편에 접착하고, 상온의 증류수에 24시간 동안 보관한 후, 전단결합강도를 측정하였다. 열순환처리 후 접착강도 실험은, 열순환처리 전 접착강도 실험에서 우수한 전단결합강도를 보인 지르코니아 표면처리군(알루미나 분사와 Rocatec 처리를 하고 3종류의 레진시멘트를 접착한 3개의 군)과 대조군으로 알루미나만으로 표면처리 후 Super-bond C&B를 접착한 1개의 군을 대상으로 $5^{\circ}C$와 $55^{\circ}C$사이에서 5,000회 열순환처리를 시행하고 전단결합강도를 측정하였다. 결과: 열순환처리 전 접착강도 실험에서는 알루미나 분사와 Rocatec 처리를 한 지르코니아 표면에 Super-bond C&B를 접착한 군이 가장 높은 전단결합강도를 보였다. Super-bond C&B를 사용한 군이 다른 시멘트 군보다 유의성 있게 높은 전단결합강도를 보였으며, 지르코니아 표면에 Rocatec 처리를 한 군이 다른 표면처리를 한 군보다 유의성 있게 높은 전단결합강도를 보였다. 열순환처리를 한 후에는, Rocatec 처리를 한 지르코니아 표면에 Super-bond C&B를 접착한 군만이 유일하게 전단결합강도가 증가하였으며, 다른 모든 군에서는 전단결합강도가 감소하였다. 결론: 본 실험에서는 Super-bond C&B 시멘트가 가장 높은 전단결합강도를 보였으며, Rocatec 시스템은 레진시멘트와 지르코니아의 전단결합강도를 향상시키는 방법이 될 것이라고 사료된다. Purpose: The purpose of this study was to evaluate the effect of surface treatment on the shear bond strength of zirconia ceramic to 3 resin cements. Materials and methods: A total of 143 disk-shaped Zirconia blocks (HASS Co., Gangneung, Korea) were randomly divided into three treatment groups: (1) only 50 ${\mu}m$ $Al_2O_3$ sandblasting, (2) 50 ${\mu}m$ $Al_2O_3$ sandblast and zircona liner, (3) 50 ${\mu}m$ $Al_2O_3$ sandblasting and Rocatec (3M ESPE, Seefeld, Germany). Bistite II (Tokuyama Dental Co., Japan), Panavia F (Kuraray Medical, Japan), and Superbond C&B (Sun Medical, Japan) were used to cement onto the zirconia. After 24h of storage in distilled water, shear bond strength was evaluated. High value group was re-tested after thermocycling at 5,000 cycles(5-$55^{\circ}C$). Shear bond strength data were analyzed with one-way ANOVA, two-way ANOVA test and Post Hoc Test (${\alpha}$=.05). Shear bond strength data before and after thermocycling were analyzed with Independent sample T test (${\alpha}$=.05). Results: Super-bond C&B treated with Rocatec showed the most high shear bond strength. Super-bond C&B groups resulted in significantly higher than other cement groups (P<.05). Rocatec groups resulted in significantly higher than other surface treatment groups (P<.05). Shear bond strength has increased in Panavia F treated with Zirconia liner (P<.05). After thermocycling, shear bond strength was increased in Super-bond C&B treated with Rocatec but decreased in other groups (P<.05). Conclusion: Super-bond C&B cement resulted the highest shear bond strength and Rocatec system enhanced the shear bond strength. After thermocycling, shear bond strength has decreased in most resin cements except Super-bond C&B treated with Rocatec.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼