발열체와 부분 열림 수직벽을 갖는 사각 공간 내 자연대류 특성 해석
심동식,강보선,차동진,주원종,Sim, Dong-Sik,Gang, Bo-Seon,Cha, Dong-Jin,Ju, Won-Jong 대한기계학회 2000 大韓機械學會論文集B Vol.24 No.12
Natural convection heat transfer in an enclosure with an opening in the right veritcal wall and a heat source at the bottom surface is investigated using a holographic interferometric technique. The effects of the opening length, divider length attached to the top wall, and heater temperature on the temperature distribution are examined. The opening length as well as the divider length greatly affects the degree of inflow and outflow of air. In the case of small opening length, the opening doesnt affect much the upward warm air flow resulting in the symmetric temperature distribution .The upward flow in hindered by the divider resulting in the decrease of heat transfer from the heater region to the upper region. The longest divider shows the highest temperature in the lower region of enclosure. In the case of large opening length, the inward cold flow moves the upward flow to the left direction. Among the cases of different divider length, the case of H(sub)d=0.25H shows the highest temperature in the lower region of enclosure.
대퇴골 전자간 불안정 골절에서 활강 지연 나사의 전후방 경사와 안정성과의 관계
양규현,유제현,이동주,원정훈,김대야,심동식 대한골절학회 2004 대한골절학회지 Vol.17 No.4
목적 : 대퇴골 전자간 불안정 골절에서 활강 지연 나사의 전-후방 경사에 따른 근위 골편의 활강 양상을 측정하여 지연 나사의 전후 또는 후전 삽입 경로가 골절편의 안정성에 미치는 영향을 알아보고자 하였다. 대상 및 방법 : 10개의 근위 대퇴 인조골(Synbone^(TM), Proximal femur)에 AO type A2.1 불안정 전자간 골절을 재현하여 5례씩 두 군으로 나눈뒤, 제 1군에서는 측면 사진상 전-후 방향으로, 제 2군에서는 후-전 방향으로 삽입각을 정한 상태에서 135도 활강 압박 고 나사로 고정하였다. lnstron 6022로 500N의 주기적 부하를 30회 가한 후 근위 골편의 활강거리 및 회전각을 측정하여 지연 나사 삽입각의 차이에 의한 활강 및 회전 정도를 분석하였고, Mann-Whitney U-test로 통계학적 검증을 하였다. 결과 : 제 1군은 평균 9.0 mm 활강하였고 제 2군은 평균 9.2 mm 활강하였으며, 통계학적으로 유의한 차이는 없었다 (p=0.92). 제 1군의 회전각은 평균 13.4도로 제 2군의 평균 8.0도에 비하여 유의하게 컸으며 (p=0.012), 제 1군에서만 5례 중 3례에서 원위 골편의 전방 피질골에 골절이 발생하였다. 결론 : 대퇴골 전자간 불안정 골절에 있어서 근위 골편의 활강은 지연 나사가 삽입된 전-후 경사에 의해 영향을 받을 수 있으며, 근위 및 원위 골편의 조기 편심성 접촉은 근위 골편의 회전을 유발시키고, 제 1군에서는 3례에서 원위 골편의 전방 피질골 골절을 일으켰다. Purpose : To investigate the characteristics of the sliding pattern of the proximal fragment(head and neck) in unstable intertrochanteric fractures, which were fixed with a dynamic hip screw(DHS) with anterior to posterior or posterior to anterior insertion angle in the axial view. Materials and Methods : AO type A2.1 intertrochanteric fracture was reproduced in 10 proximal femur model (Synbone, Malans, Switzerland). Five fractured models were reduced and fixed using DHS with anterior to posterior insertion angle (group 1) and five models were fixed with posterior to anterior angle (group 2). Load of 500 N (30 cycles) was applied to the fracture fragment-plate complex using lnstron 6022. Data on the distance of sliding and the angle of rotation of the proximal fragment were collected and analyzed. Results : No significant difference was noted statistically in the distance of sliding between the two groups (p=0.92). However, the mean angle of rotation was 13.4° and 8.0° in group 1 and 2, respectively and the difference was statistically significant (p=0.012). Anterior cortical fracture of distal fragment was noted in 3 cases of group 1. There was no fracture of the anterior cortex in group 2. Conclusion : In unstable intertrochanteric fracture, the insertion angle of the lag screw in axial view does seem to play a role in the fate of bone-plate complex. Early eccentric contact of both fragments caused rotation of the proximal fragment in all cases and anterior cortical fracture of the distal fragment in 3 cases of group 1.