http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
배석주(Suk Joo Bae),김만수(Mansoo Kim) 한국산업경영시스템학회 2008 한국산업경영시스템학회 학술대회 Vol.2008 No.하계
Gate oxide breakdown is a key mechanism limiting IC lifetime. In this paper, we examine the characteristics of time dependent dielectric breakdown (TDDB) for ultra-thin gate oxide based on percolation models. From fractal theory describing complex geometrical structures, we investigate the relationship between the gate oxide structure and the critical defect density in ultrathin gate oxide breakdown.
학술 7 특별구두세션 : F2. 학술세션 QM 적용: 국방 ; 국방 군수업체 품질경영 수준 평가 모델 개발
배석주 ( Suk Joo Bae ),정규석 ( Kyu Suk Chung ),류문찬 ( Moon Charn Riew ),임성욱 ( Sung Uk Lim ),김명준 ( Myung Joon Kim ),김성도 ( Sung Do Kim ),양지응 ( Ji Eung Yang ),박상호 ( Sang Ho Park ) 한국품질경영학회 2014 한국품질경영학회 학술대회 Vol.2014 No.2
1. 목적 · 기존 모델을 조사하고 분석하여 국내 국방 군수업체 품질경영 수준을 진단하고 평가하기 위한 모델 제시 2. 연구설계/ 방법론/ 접근방법 · 기존 ME, EQA, JQA 모델을 비롯하여 국내 모델들의 특징을 살펴보고 국내 실정에 맞는 정량 지표도출과 정성적 지표의 객관화 평가를 위한 표준척도 마련 3. 연구결과 · 국방 분야의 특징을 살피고 수준진단을 통해 정책제시 및 로드맵 작성 방안 제시 4. 실무적 시사점 · 국내 국방분야 특성을 반영한 모델 제시 및 객관화된 지표 마련 5. 독창성/ 가치 · 과정과 결괴를 따로 측정하는 방식에서 탈피하여 평가항목의 인과관계를 강화하고 러닝 개념을 도입하여 현재 상태뿐만 아닌 과거와 미래까지 트렌드를 파악하여 평가할 수 있는 모델 확장
PEMFC 고분자 막의 전기화학적 가속 열화에 미치는 평가조건들의 영향
오소형,유동근,배석주,채선규,박권필,Sohyeong Oh,Donggeun Yoo,Suk Joo Bae,Sun Geu Chae,Kwonpil Park 한국화학공학회 2023 Korean Chemical Engineering Research(HWAHAK KONGHA Vol.61 No.3
In order to improve the durability of the proton exchange membrane fuel cell (PEMFC), it is important to accurately evaluate the durability of the polymer membrane in a short time. The test conditions for chemically accelerated durability evaluation of membranes are high voltage, high temperature, low humidity, and high gas pressure. It can be said that the protocol is developed by changing these conditions. However, the relative influence of each test condition on the degradation of the membrane has not been studied. In chemical accelerated degradation experiment of the membrane, the influence of 4 factors (conditions) was examined through the factor experiment method. The degree of degradation of the membrane after accelerated degradation was determined by measuring the hydrogen permeability and effluent fluoride ion concentration, and it was possible to determine the degradation order of the polymer membrane under 8 conditions by the difference in fluoride ion concentration. It was shown that the influence of the membrane degradation factor was in the order of voltage > temperature > oxygen pressure > humidity. It was confirmed that the degradation of the electrode catalyst had an effect on the chemical degradation of the membrane.