RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        전후방 및 내외측 방향의 동적 움직임에 따른 균형 및 근육 활성도 특성

        김충연,정호현,이범기,정덕영,전경진,임도형,Kim, ChoongYeon,Jung, HoHyun,Lee, BumKee,Jung, Dukyoung,Chun, Kyeong Jin,Lim, Dohyung 대한의용생체공학회 2013 의공학회지 Vol.34 No.4

        Falling is one of the major public problems to the elderly, resulting in limitations of daily living activities. It can be induced by the functional loss of the balance ability and muscle strength in the elderly. It has been, however, not well investigated to suggest an effective methodology improving the balance ability and muscle strength for the prevention of the falling due to lack of information about the characteristics of the balance and muscle activations responded to the dynamic motions. The aim of the current study is, therefore, to identify the characteristics of the balance and muscle activations responded to the dynamic motions in Anterior-Posterior(AP) and Medial Lateral(ML) directions. For that, a motion capture system with eight infrared cameras, surface electromyogram system and Wii Fit system with a customized variable unstable base were used and kinematic and kinetic data obtained from the systems were analyzed for five healthy male($24.8{\pm}3.3years$, $177.4{\pm}2.0cm$, $73.9{\pm}12.9kg$, $23.5{\pm}4.0kg/m$). The results showed that the characteristics of the balance and muscle activations were differently responded to between the dynamic motions in Anterior-Posterior(AP) and Medial Lateral(ML) directions. These findings may indicate that customized dynamic motions should be applied to the training of the balance ability and muscle strength for the effective prevention of the falling. This study may be meaningful to providing basic information to establish a guideline improving effectively the balance ability and muscle strength.

      • KCI등재

        균형 재활 훈련을 위한 특정 회전 움직임에서 피검자 동작 분석을 위한 깊이 센서 기반 키넥트 시스템의 정확성 및 부정확성 평가

        김충연,정호현,전성철,장경배,전경진,Kim, ChoongYeon,Jung, HoHyun,Jeon, Seong-Cheol,Jang, Kyung Bae,Chun, Keyoung Jin 대한의용생체공학회 2015 의공학회지 Vol.36 No.5

        The balance ability significantly decreased in the elderly because of deterioration of the neural musculature regulatory mechanisms. Several studies have investigated methods of improving balance ability using real-time systems, but it is limited by the expensive test equipment and specialized resources. Recently, Kinect system based on depth data has been applied to address these limitations. Little information about accuracy/inaccuracy of Kinect system is, however, available, particular in motion analysis for evaluation of effectiveness in rehabilitation training. Therefore, the aim of the current study was to evaluate accuracy/inaccuracy of Kinect system in specific rotational movement for balance rehabilitation training. Six healthy male adults with no musculoskeletal disorder were selected to participate in the experiment. Movements of the participants were induced by controlling the base plane of the balance training equipment in directions of AP (anterior-posterior), ML (medial-lateral), right and left diagonal direction. The dynamic motions of the subjects were measured using two Kinect depth sensor systems and a three-dimensional motion capture system with eight infrared cameras for comparative evaluation. The results of the error rate for hip and knee joint alteration of Kinect system comparison with infrared camera based motion capture system occurred smaller values in the ML direction (Hip joint: 10.9~57.3%, Knee joint: 26.0~74.8%). Therefore, the accuracy of Kinect system for measuring balance rehabilitation traning could improve by using adapted algorithm which is based on hip joint movement in medial-lateral direction.

      • KCI등재

        기구학적 운동이 돼지 무릎 관절연골의 마찰계수 변화에 미치는 영향

        김환(Hwan Kim),김충연(ChoongYeon Kim),이권용(KwonYong Lee),김대준(DaeJoon Kim),임도형(DoHyung Kim) 한국트라이볼로지학회 2013 한국트라이볼로지학회지 (Tribol. Lubr.) Vol.29 No.1

        In this study, the frictional behaviors of articular cartilage against a Co-Cr alloy in two types of kinematic motions were compared. Cartilage pins were punched from the femoral condyles of porcine knee joints, and Co-Cr alloy disks were machined from orthopedic-grade rods and polished to a surface roughness (Ra) of 0.002. Friction tests were conducted by using a pin-on-disk?type tribotester in phosphate buffered saline (PBS) under pressures of 0.5, 1, and 2 MPa. All tests were performed in the repeat pass rotational (ROT) and the linear reciprocal (RCP) sliding motions with the same sliding distance and speed of 50 ㎜/s. The coefficients of friction of the cartilage against the Co-Cr alloy increased with the sliding time in both kinematic motions for all contact pressures. The maximum coefficients of friction in RCP motion were 1.08, 2.82, and 1.96 times those in ROT motion for contact pressures of 0.5, 1, and 2 MPa, respectively. As the contact pressure increased, the coefficients of friction gradually increased in RCP motion, whereas they decrease and then increased in ROT motion. The interaction between the directional change of the shear stress and the orientation of collagen fiber in the superficial layer of the cartilage could affect the change in the frictional behaviors of the cartilage. A large difference in the coefficients of friction between the two kinematic motions could be interpreted as differences in the directional change of shear stress at the contact surface.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼