http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
무치악 환자에서 하악 임플랜트 지지 피개의치에 의한 즉시 하중 부담에 관한 연구
김장욱,김형섭,백진,권긍록,Kim, Jang-Wook,Kim, Hyeong-Seob,Baik, Jin,Kwon, Kung-Rock 대한치과보철학회 2007 대한치과보철학회지 Vol.45 No.1
Statement of problem: Conventional mandibular complete denture lacks in support and stability for edentulous patients to use. Purpose: To enhance support and stability of mandibular complete denture, 2 implants were inserted on the inter-mental foramina space of edentulous patients. With 2 magnetic attachments on the inner side of the overdenture, we gave immediate loads and evaluated the stability of the implants, the responses of the supporting tissues, and the satisfaction of the patients. Material & methods: 6 edentulous patients (5 male, 1 female) each recieved 2 SLA implants in the inter-mental foramina region and implants were immediately loaded with overdenture with magnet attachments. To evaluate the implants stability and the peri-implant tissues, clinical exams, RFA tests and radiographic exams were preformed at the 1 week, 2wks, 6wks, 12wks, and 24wks. post- surgery. Results: The mean surgery time was $45.7{\pm}7.7mins$., while the denture delivery time was $45.5{\pm}12.6mins$. Only 2 of 14 implants were failed. Survived implants that remained were clincally and radiographically stable. Mean ISQ values were relatively stable, showing $69.71{\pm}5.55$, $69.00{\pm}9.48$, $67.92{\pm}7.86$, $67.92{\pm}9.58$, $70.08{\pm}7.61$, $71.92{\pm}6.43$ at the 1 wk, 2 wks, 6 wks, 12 wks, 24 wks. follow up check. Crestal bone changes were $-1.18mm{\pm}0.68mm$, $-1.35{\pm}0.69mm$, $-1.47{\pm}0.68mm$ at the 6wks, 12wks, 24wks. follow up check. Bleeding on probing(BOP index) was not significant. Conclusion: Mandibular ovedentures with 2 magnetic attachments over two interforaminal implants on edentulous patients for immediate function is a recommendable novel treatment for edentulous patients which shows stability on the implants and supporting tissue.
김장욱,최완,오창헌,조성준,Kim, jang-Wook,Choi, Wan,Oh, Chang-Heon,Cho, Sung-Joon 한국전자파학회 2002 한국전자파학회논문지 Vol.13 No.1
이동통신 시스템에서 지하 주차장, 지하상가, 터널, 빌딩 내부 등과 같이 기지국에 의한 신호의 커버리지가 충분하지 못한 지역들이 발생하게 된다. 이러한 영역의 경제적인 해결 방안으로 중계기가 널리 사용된다. 그러나, 중계기의 수가 증가할수록 역방향 링크의 기지국으로 유입되는 잡음 전력이 중계기의 숫자에 비례하여 증가하기 때문에 채널 용량이 감소하게 된다. 수십, 수백개의 중계기가 하나의 기지국에 연결되는 상황에서 이러한 채널 용량의 감소는 더 이상 무시할 수 없다. 본 논문에서는 커버리지 내에 통화 중인 사용자가 없을 때에 자동적으로 동작하지 않는 스위칭 중계기론 제안하였다. 스위칭 중계기를 사용하면 중계기의 커버리지 내에 통화중인 사용자가 없을 때 불필요한 잡음 레벨을 줄일 수 있다. 스위칭 중계기를 사용한 이동통신 시스템의 역방향 링크 채널 용량을 수학적으로 분석하여 스위칭 중계기를 사용하지 않는 상황과 비교하였다. 그 결과 스위칭 중계기를 사용할 때 충분히 채널용량이 개선되었음을 알 수 있었다. In mobile communication systems, there are areas where signal coverage is not adequately accomplished by base stations. These areas may be underground parking zones, underground stores, tunnels, and insides of buildings, etc. In these areas, repeaters are broadly used as an economical solution. However, the capacity is decreased as the number of repeaters increases because the noise power that flows to a base station in the reverse link is proportional to the number of repeaters. The reduction of capacity in the reverse link is no longer negligible in the case that several tens or hundreds repeaters are connected to a base station. In this paper, we propose c repeater that is switched off automatically when there is no active user within its coverage. With the switching repeater, we can reduce the unnecessary noise level enhancement when there is no active user within the repeaters coverage. The reverse link capacity of a DS/CDMA system with AOS repeater is analyzed mathematically and compared with that without switching repeater. From the numerical results, noticeable improvement with the switching repeaters is shown.
인위적인 습해 유발조건에서 2년생 인삼 품종의 생육특성
김장욱(Jang-Uk Kim),이정우(Jung-Woo Lee),조익현(Ick-Hyun Jo),김동휘(Dong-Hwi Kim),김기홍(Kee-Hong Kim),김영창(Young-Chang Kim) 충남대학교 농업과학연구소 2015 농업과학연구 Vol.42 No.4
This study was conducted to investigate growth characteristics to develop the technique to select resistant cultivar by wet injury at an early stage through the automatic irrigation maintaining 30, 20, 10 kPa respectively using native variety, Chunpoong, Yunpoong, Gumpoong and Sunun. The aerial growth was decreased at 10 kPa compared to 30 kPa. In addition, the survival rate was decreased by 66.6%, 62.3%, 33.8% at 30, 20, 10 kPa, respectively. The survival rate of Chunpoong and Gumpoong were higher than others at 10 kPa. While root growth characteristics such as root length, root weight, number of lateral root and side root were tended to decrease, root diam was no significant or increased. And the more humid condition is, the more the incidence rate of rusty root and rough skin were tended to increase. The epidermal thickness of Chunpoong and Gumpoong was increased but the figures of native variety, Yunpoong and Sunun were decreased at 10 kPa compared to 30 kPa. But, the tissue stiffness of root was decreased at 10 kPa compared to 30 kPa.