남조류 제거를 위한 선회식 가압부상장치 현장 적용에 관한 연구
오홍석 ( Oh Hong-sok ),강선홍 ( Kang Seon-hong ),남숙현 ( Nam Sook-hyun ),김은주 ( Kim Eu-ju ),구재욱 ( Koo Jae-wuk ),황태문 ( Hwang Tae-mun ) 한국환경복원기술학회(구 한국환경복원녹화기술학회) 2018 한국환경복원기술학회지 Vol.21 No.5
Cyclonic-dissolved air flotation(Cyclonic-DAF), an advanced form of pressure flotation, applies a structure that enables the forming of twirling flows. This in turn allows for suspended matter to adhere to microbubbles and float to the surface of a treatment tank during the process of intake water flowing through a float separation tank. This study conducted a lab-scale test and pursued geometrical modeling using computational fluid dynamics(CFD) to establish a pilot scale design. Based on the design parameters found through the above process, a pilot cyclonic-DAF system(10㎥/hr) for removing algae was created. Upon developing the pilot-scale cyclonic-DAF system, a type of algae coagulant(R-119) was applied as the coagulant to the system for field testing through which the removal rates of chlorophyll-a and cyanobacteria were evaluated. The chlorophyll-a and harmful cyanobacteria of the raw water at region B, the field-test site, were found to be 177.9mg/㎥ and 652,500cells/mL respectively. Treated waters applied with 60mg/L and 100mg/L of algae coagulant presented removal efficiencies of approximately 95% and 97%, respectively. The cyanobacteria cell number of the treated waters applied with 60mg/L and 100mg/L of algae coagulant both that were equal to or less than 1,000cells/mL and were below attention level criteria for the issuance of algae boundary.