http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
증예(症例) : 급성 췌장염으로 발현된 부갑상선 기능항진증 1예
윤찬호 ( Chan Ho Youn ),황민호 ( Min Ho Hwang ),송민섭 ( Min Seob Song ),김용문 ( Young Mun Kim ),김정화 ( Jeong Wha Kim ),김세화 ( Se Hwa Kim ),김동윤 ( Dong Youn Kim ) 전북대학교 의과학연구소 2001 全北醫大論文集 Vol.25 No.1
저자들은 심한 급성 췌장염을 동반한 부갑상선 기능항진증 환자에서 부갑상선종 수술후 급성췌장염이 치유된 1 예을 경험하였기에 이에 문헌고찰과 함께 보고하는 바이다. An association of hyperparathyroidism and pancreatitis has been documented in 1934 by Dr. McMahon. Deposition of insoluble calcium salts in pancreas is regarded as one of the possible pathophysiologic causes. A 16-year-old male was admitted to the hospital because of severe abdominal pain and vomiting. The results of abdominal CT and biochemical blood tests was acute pancreatitis but serum calcium level was high. A parathyroid mass was detected by neck ultrasonogram. After surgical removal of the parathyroid adenoma, serum calcium level became normalized and pancreatitis was improved. We report a case of primary hyperparathyroidism manifested with pancreatitis and also discuss the possible cause and relationship between primary hyperparathyroidism and pancreatitis.
전주산업단지 및 주변지역 VOCs 및 악취물질 모니터링
김용문,박비오,고영삼,심재정,송병식,양고수 전북대학교 공학연구원 ( 구 전북대학교 공업기술연구소 ) 2002 工學硏究 Vol.33 No.-
Important main odorous compounds and VOCs(volatile organic compounds) possibly emitted from the Jeon-Ju Industrial Sites were identified and measured in amount through making air sampling over Jeon-Ju Industrial Sites and analyzing them with the sate of the art analytical instrument. Sampling sites were chosen 8 points by considering the industrial characteristics for the 1,2 Industrial Sites and 2 points for the 3 Industrial. Site Sampling times were two times, the first one was March. 2002 - April. 2002, and the second was May. 2002 - July. 2002. Canister sampling units and polyester bags were used to collect 6 liters air samples during 1hour or 3minutes for VOCs and polyester bags were used to sample 10 - 50 liters of air for 3 minutes depending on analytic characteristics of odor compounds. The important main VOCs were measured as acetone, ethyl benzene, n-hexane, m,p-xylene, toluene, M.E.K.(methyl ethyl ketone), isopropanol, ethyl acetate, o-xylene, n-butyl acetate, ethanol, benzene as in order of average concentration for the Industrial Sites. The main odorous compounds were COS, H2S, CS2, MM(methyl mercaptan), form aldehyde, acetaldehyde for the 1,2 Industrial Sites and COS, H2S, form aldehyde, acetaldehyde were measured as main species for the 3 Industrial Site. NH3 was measured as below the detection limit of the instrument. The concentrations of sulfide compounds for the 1,2 Industrial Sites were relatively higher than ones for the 3 Industrial Site. Among aldehydes, form aldehyde, acetaldehyde were detected very highly as 0.1- 1ppm over all the Industrial Sites.