http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
발작을 주소로 내원한 Walker-Warburg 증후군 1례
김성구(Seong Koo Kim),이진영(Jin Young Lee),김영훈(Young Hoon Kim),이인구(In Goo Lee) 대한소아신경학회 2010 대한소아신경학회지 Vol.18 No.2
Walker-Warburg syndrome (WWS) is a rare autosomal recessive disorder characterized by congenital muscular dystrophy, brain (lissencephaly, hydrocephalus, cerebellar malformations) and retinal abnormalities, and is associated with mental retardation and seizures. In 1942, Walker was the first to report a case of WWS. As Fukuyama congenital muscular dystrophy or muscle-eye-brain disorder, it has been demonstrated that the glycosylation defects of α-dystroglycan which take a great role in muscle and neuron regeneration are at the root of these disorders. We report a five months old male patient who was presented with seizures as the chief complaint and was diagnosed with WWS, based on clinical criteria, MRI, muscular biopsy, ocular examination, and laboratory findings.
케로신/액체산소의 고압 연소해석을 위한 열역학/전달 물성치 해석 패키지 개발
김성구(Seong-Ku Kim),최환석(Hwan-Seok Choi) 한국추진공학회 2011 한국추진공학회 학술대회논문집 Vol.2011 No.5
초임계 압력 조건에서 분사된 액체추진제의 혼합 및 연소 현상을 해석하기 위해서는 열역학적 비이상성과 전달 물성치의 특이성을 예측하는 것이 선행되어야 한다. 본 연구에서는 일반화된 3차 상태방정식(cubic EoS)을 기반으로 실제유체의 열역학/전달 물성치를 계산하는 서브루틴들을 개발하였으며, 표준 화학반응 패키지인 Chemkin과 쉽게 연동될 수 있도록 하였다. 실제유체 해석 패키지를 이용하여 기존의 층류화염편 코드를 확장하였으며, 실제 로켓엔진이 갖는 고압 연소조건하에서 케로신과 액체산소의 국소화염구조에 대한 수치해석 연구를 수행하였다. The modeling of thermodynamic non-idealities and transport anomalies is a crucial prerequisite to realistically simulate the mixing and combustion processes of liquid propellants injected above critical pressures. This study has developed a specific set of subroutines to calculate the thermodynamic and transport properties based on the generalized cubic equation of state (EoS) in a coupled manner with the standard chemical kinetics packages (Chemkin). The existing flamelet analysis code is extended with the real-fluid package and applied to numerical investigation of local flame structures of kerosene and liquid oxygen at high pressure conditions relevant to the actual rocket engines.
화염전달함수와 Helmholtz solver를 이용한 모델 연소기의 연소불안정 연구
김성구(Seong-Ku Kim),최환석(Hwan-Seok Choi),김대식(Daesik Kim),차동진(Dong Jin Cha) 한국추진공학회 2013 한국추진공학회 학술대회논문집 Vol.2013 No.5
본 연구에서는 최근에 개발된 Helmholtz solver를 이용하여 예혼합 가스터빈 모델 연소기에서 종방향 음향 모드로 발생하는 자발 연소불안정을 해석하였다. 음향섭동에 대한 화염의 응답특성은 속도감응 시간지연모델을 적용하였으며, 모델 파라미터들은 실험으로부터 계측된 화염전달함수를 통해 결정하였다. 연소실 길이를 변경시켰을 때, 연소시험 결과와 유사한 구간에서 2차 종 방향 모드의 자발 불안정이 예측되었으며, 입구의 음향 특성은 연소불안정의 발생 여부뿐만 아니라 공진 주파수와 모드 형태에도 큰 영향을 미치는 것으로 나타났다. This study investigated numerically longitudinal combustion instability of a lean premixed model gas-turbine combustor using a recently developed Helmholtz solver. The response of heat release rate to acoustic perturbation was modeled based on the velocity-sensitive time-lag theory, whose parameters were determined by experimentally measured FTF (Flame Transfer Function). The present model predicted spontaneous instabilities in second longitudinal mode for certain range of combustion chamber length, which is in line with the experiment. The numerical result clearly reveals that the acoustic boundary condition at the inlet affects greatly the resonant frequency and mode shape of the combustion instability as well as its growth rate.
흡입 기관지 확장제의 기도반응 판정을 위한 폐기능 검사 지표에 관한 연구
김주옥(Ju Ock Kim),심영수(Young Soo Shim),한성구(Sung Koo Han),김건열(Keun Youl Kim),한용철(Yong Chol Han),김선영(Sun Young Kim) 대한내과학회 1987 대한내과학회지 Vol.33 No.5
N/A Bronchodilator inhalation test is a useful method to detect the bronchial hyperreactivity and many kinds of pulmonary function parameters have been used to quantify this change of post-bronchodilator inhalation. Although FEV1.0 has long been used most commonly for this purpose, there become available more various kinds of pulmonary function parameters, recently, such as FVC time, MEF50, MEF75, airway resistance etc for the evaluation of these ventilatory function. Hewlett-Packard computer pulmonary calculation system (HP 47804A) provide 18 parameters of pulmonary ventilatory function and we have evaluated the relation between FEV1.0 and other available 17 parameters of HP 47804A system for the evaluation of bronchodilator response. 190 subjects who have shown positive bronchodilator test (15% increase of FEV1.0 after inhalation of fenoterol) were collected for the study and obtained the following results. 1) All of the parameters showed significant change after bronchodilator inhalation, however, the magnitude of change are more significant in order of following parameters: FEV2.0, FEV1.0, FEV3.0, FVC time, FVC, PF, FEF0.2-1.2, FEF25-75, MEF50, and FEV0.5. 2) In pre-bronchodilator test, FEV1.0 is more closely correlated with FEV2.0 (r=0.986), FEV3.0 (r=0.967), FEF0.2-1.2 (r=0.930), and FEF25-75 (r=0.91). 3) In post-bronchodilator test, FEV1.0 is mare closely correlated with FVC time (r=0.987) and FEV2.0 (r=0.987), and subsequent orders are as follows: FEV0.5 (r=0.977), FEV3.0 (r=0.964), FEF0.2-1.2 (r=0.954), FEF25-75 (r=0.917), MEF50 (r=0.908), and FVC (r=0.818). 4) Regression equations between FEV1.0 and various other parameters are expressed in pre- and post-bronchodilator inhalation test.
김성구(Sunggoo Kim),이성길(Sungkil Lee) 한국정보과학회 2016 정보과학회논문지 Vol.43 No.4
컴퓨터그래픽스에서 지연된 음영처리는 깊이 버퍼링을 이용하여 화면에 나타날 기하 정보만을 저장한 후, 픽셀 음영처리를 화면공간에서 후처리하는 기법이다. 일반적인 그림자 매핑과 달리 후처리 기반 기법은 렌더링 파이프라인 구조의 변화 없이 적용이 가능하므로 다중 광원에 의한 그림자 효과를 다루기에 적합하다. 본 논문에서는 지연된 음영처리 기반의 그림자 생성 방법과 밉맵을 이용하여 이를 부드러운 그림자로 확장하는 방법을 제안한다. 광원으로부터 가시도 맵을 저장한 후, 밉맵 필터링을 통해 가시도맵을 블러한 후 음영처리 결과에 적용한다. 이러한 기법은 부드러운 그림자 효과를 얻지만, 픽셀 깊이에 관계없는 필터링으로 인해 빛샘 현상이 발생할 수 있다. 이러한 빛샘 현상을 제거하기 위해 본 논문은 또한 화면공간에서의 깊이 차이에 따른 적응형 샘플링 기법을 제안한다. Deferred Shading is a shading technique that postprocesses pixels in the screen space, following geometry-only rendering passes with depth buffering. Unlike typical shadow mapping techniques, this technique allows us to render shadows from multiple light sources without changing the structure of the rendering pipelines. This paper presents a deferred shadow mapping technique and its extension to soft shadows using mipmapping. Our technique first generates visibility maps from light sources, and blurs the visibility maps for deferred shading. This strategy leads to efficient soft-edged shadows, but does not incorporate depth variation, producing light bleeding to some extent. In order to suppress the light-bleeding artifacts, we also propose a depth-adaptive mipmap sampling technique in the screen space.