최도석(Do Seok Choi),김상준(Sang Jun Kim),홍민호(Min Ho Hong),김성은(Sung Eun Kim) 대한설비공학회 2018 대한설비공학회 학술발표대회논문집 Vol.2018 No.11
As the issue of energy-saving, it would be reasonable to maximize energy-saving by active factors after reducing cooling and heating loads by passive factors when designing a building. This case study introduced the energy saving design applied to the objected building, and analyzed the energy simulation about skin factor. As the result, it could be expected to decrease 22% annual energy consumption when compared case 2 for applying triple glass window and vertical louver to case 1 for applying general double glass window. For further study, it would be more meaningful to compare the result with examined result of the actual energy consumption from the objected building.
閔丙亨(Byung-Hyung Min),玉致律(Chi-Youl Ok),金佳鉉(Ga-Hyun Kim),崔道碩(Do-Seok Choi) 한국해양공학회 1988 韓國海洋工學會誌 Vol.2 No.1
A beach nourishment method can be used as one of the beach erosion protection methods which may keep coastal environments without constructing coastal structures on the beach. The beach nourishment is affected br a natural condition and an artificial condition; a natural condtion include conditions of bottom slope, diameter of bottom materials and wave, and an artificial condition include deposit position, method, diameter and quantity of the nourishing sand.<br/> To obtain and the best diameter of the nourishing sand a two-dimensional hydraulic model test, which simulates the erosional beach, has been accomplished.<br/> In this study the protection of the beach erosion can be maximized when the nourishing sand of 0.84㎜ in diameter, which is about 2.5~3.5 times of the natural bottom materials in diameter.
홍성수(Sung-Soo, Hong),이수연(Soo-Yeon Lee),최도석(Do-Seok Choi) 대한설비공학회 2016 대한설비공학회 학술발표대회논문집 Vol.2016 No.11
The purpose of this paper is to summarize the design guideline for energy saving of HVAC systems in broadcasting facilities with a variety of load characteristic zone through the author’s design experience for over 20 years. The guideline categories are as follows : (1) the load characteristic and design criteria of the broadcasting facilities, (2) the consideration for building mechanical service, (3) the design method of the heat source equipment and air conditioning system, (4) the design method of vibration absorption and soundproof for low noise zone.
서대웅(Dae Woong Seo),성노천(No Cheun Sung),성재호(Jae Ho Sung),최도석(Do Seok Choi) 대한설비공학회 2018 대한설비공학회 학술발표대회논문집 Vol.2018 No.11
냉난방 설비의 존치/교체는 성능을 측정하여 제안하는 것이 가장 이상적이다. 측정하는 냉난방 설비가 늘어날수록 많은 인력이 필요하기 때문에, 낮은 단가로 수행되는 에너지진단에서 모든 장비를 측정하는 것은 현실적으로 어렵다. 만약, 공공건물의 운영자를 통해 측정이 필요한 장비가 선별된다면, 현장조사 시간을 절약할 수 있다. 그러나 공공건물의 운영자가 진단에 대한 전문지식이 없는 경우가 대부분이기 때문에, 공공건물의 건물 운영자 수준에서 작성할 수 있는 냉난방 설비의 사전 문진표를 정립하고자 하였다. 냉난방 설비별로 진단해야할 주요 인자는 내구연한, 관리수준, 장비상태, EPI 수준(또는 고효율 전동기 사용 유무)으로 선정하였으며, 설문 결과 인자별 중요도는 평균적으로 내구연한 30%, 관리수준 25%, 장비상태 30%, EPI 수준(또는 고효율 전동기 사용 유무) 15%로 나타났다. 본 사전 문진표를 통해 운영자는 자체적으로 간이 진단을 수행할 수 있고, 진단기관은 결과를 참고하여 현장진단 시간을 줄일 수 있을 것으로 기대한다.