RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        The Effect of Thin Teflon on TLD Response for in vivo Dosimetry of Radiotherapy

        Kim, Sookil,Yum, Ha-Young,Jeong, Tae-Sig,Moon, Chang-Woo Korean Society of Medical Physics 2003 의학물리 Vol.14 No.2

        The purpose of this study was to evaluate the performance of the teflon encapsulated TLD rod, which may be used in nuclear medicine for the direct in vivo measurements of radiation dose. We analyzed the influence of teflon encapsulation for measuring absorbed dose. An experiment was carried out to evaluate and observe the response of a LiF TLD-100 rod in a thin-wall teflon capsule at different depths in a solid phantom. An adult anthropomorphic phantom was used to measure the absorbed dose using thin teflon encapsulated TLD. The measurements of PDD-, and TMR in solid phantom and athe bsorbed dose in humanoid phantom performed with normal TLD were compared with values obtained by teflon encapsulated TLD. It was demonstrated that the difference of TL response of LiF in phantom with and without teflon thin-wall capsule was less than 3% under the same conditions beyond the build-up region. However, significant differences were observed near the phantom surface because of the build-up effect caused by the thin-wall thickness of the teflon capsule. Thus, our study showed that the contribution of teflon thin-wall capsule to TLD response for the megavoltage photon beams was negligible and that it did not significantly effect dose measurement. The teflon encapsulated TLD described in this work has been proven to be appropriate for in vivo dosimetry in therapeutic environments. 본 연구의 목적은 핵의학 분야에서 생체 내 흡수선량의 직접 측정에 사용될 수 있는, 테프론을 씌운 TLD의 수행성을 알아보고, 흡수선량 측정 시 테프론의 영향에 대하여 분석하고자 한다. 테프론 캡슐에 든 LiF TLD-100의 반응감도를 고체 팬텀 내에서의 깊이를 달리 하며 측정하였다 성인 인체모형 팬텀을 이용하여 테프론을 씌운 TLD로써 생체 내 흡수선량을 측정하였다. 테프론을 씌우지 않은 보통의 TLD를 이용하여 구한 PDD, TMR, 그리고 생체흡수선량과 테프론을 씌운 TLD로 구한 값을 비교하였다. 보통의 TLD를 이용하여 구한 반응값과 테프론을 씌운 TLD로 구한 값의 차이는 build-up이상의 깊이에서는 같은 조건하에서 3% 이내였다. 그러나 팬텀 표면 부근에서는 테프론 켑슐의 두께에 기인한 build-up 효과로 인해 큰 차이를 보였다. 본 연구에서 테프론 켑슐로 인하여 수 메가볼트의 방사선에 대한 TLD의 흡수선량 측정에 미치는 변화는 미미한 것으로 나타났다. 따라서 치료 환경 하에서 테프론을 씌운 TLD가 생체 내 선량측정에 매우 적합한 것으로 사료된다.

      • SCOPUSKCI등재

        Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

        Hur, Yeoun,Tae, Sookil,Koh, Yun-Joo,Hong, Sung-Hyun,Yoon, Young Ho,Jang, Haejong,Kim, Sooji,Kim, Kyeong Ho,Kang, Seung Woo,Lee, Youngshin,Han, Sang Beom Korean Society for Mass Spectrometry 2014 Mass spectrometry letters Vol.5 No.2

        A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column ($150mm{\times}2.0mm$, $4{\mu}m$) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/v) at a flow rate of $450{\mu}L$/min. Porphyrins and the internal standard (IS), coproporphyrin I-$^{15}N_4$, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.

      • SCOPUSKCI등재

        Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

        ( Yeoun Hur ),( Sookil Tae ),( Yun Joo Koh ),( Sung Hyun Hong ),( Young Ho Yoon ),( Haejong Jang ),( Sooji Kim ),( Kyeong Ho Kim ),( Seung Woo Kang ),( Youngshin Lee ),( Sang Beom Han ) 한국질량분석학회 2014 Mass spectrometry letters Vol.5 No.2

        A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESIMS/ MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column (150 mm × 2.0 mm, 4 μm) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/ v) at a flow rate of 450 μL/min. Porphyrins and the internal standard (IS), coproporphyrin I-15N4, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.