http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
조나영,박성준,최호정,정성목,송근호 忠南大學校 獸醫科大學 附設 動物醫科學硏究所 2012 動物醫科學硏究誌 Vol.19 No.1
A Bicon Frise (7-month-old, intact female, B.W.: 3.5kg) was referred to the Veterinary Medical Teaching Hospital of Chungnam National University with the history of the murmur which was picked up during routine vaccination. The grade 3 of continuous murmur was identified on the auscultation. In the thoracic radiography, descending aorta and main pulmonary artery were enlarged and vertebral cardiac scale (VHS) was 10. In the echocardiography, turbulent and continuous positive flow was identified in the pulmonary artery at the right parasternal short axis view. We found the patent ductus arteriosus (PDA) connected the main pulmonary artery with the aorta by CT image. So, the diagnosis of PDA was made. The continuous murmur was not identified on the auscultation after surgical correction was achieved by ligation of PDA.
Si Bulk Micromachining을 위한 Wafer Rolling Etching 및 그 특성
김건년,이보나,박효덕,신상모,공경준,장동근,김병철,권혁채,이봉희 경북대학교 센서기술연구소 1998 센서技術學術大會論文集 Vol.9 No.1
A wafer rolling etching system for the silicon bulk micromachining has been designed and fabricated. The silicon diaphragms were anisotropically etched in a 24.5 weight percent KOH solution. Compared to the conventional KOH etching systems, pyramidal hillocks, and wave-shaped structures on the etched surfaces were greatly reduced by using this system. After etching for time of 438 minutes, the average etched depth and the etch-rate were measured to be 537μm and 1.22μm/min, respectively. The average etching uniformity of etching depth was 0.87% in 5-inch wafer. Our results showed that the wafer rolling method enhanced etch uniformity and etch rate.
김건년,이보나,박효덕,신상모,이근혁,권혁채 경북대학교 센서기술연구소 1998 센서技術學術大會論文集 Vol.9 No.1
In this paper, we studied the anodic bonding of 5-inch silicon and #7740 Pyrex glass wafers with a thickness of 3mm by using the EV501 bonder and the Karl Suss SB6 bonder. The test conditions for anodic bonding of the EV501 bonder system with a full field electrode were temperature of 400 ℃ and voltage of 800V in a chamber pressure of 1X10^(3)mbar. The SB6 bonder with a star shaped electrode was tested at the temperature and voltage of 450 ℃ and 1300V in the atmosphere, respectively. As the results of test, we obtained the void free samples regardless of shape of substrates such as etched wafers with cavities and drilled glasses with holes.
집적화된 실리콘 압력센서의 출력전압 보상파라미터 추출 및 그 특성
이보나,김건년,박효덕,신상모,이경탁,김찬,권혁채,이상조,박현주 경북대학교 센서기술연구소 1998 센서技術學術大會論文集 Vol.9 No.1
An integrated silicon pressure sensor has been designed, fabricated and tested. The signal conditioning circuits were designed to include calibration and temperature compensation of output voltage through trimming of diffusion and ion-implanted resistors. Before trimming of resistors, the compensation parameters such as pressure sensitivity, temperature coefficient of pressure sensitivity, temperature coefficient of piezoresistors and pressure sensitivity of piezoresistors were measured. Then offset voltage, span, and temperature coefficients of offset voltage and span were calibrated by trimming of resistors. The measured output voltage met our design specification and simulation value above room temperature. But, the measured output voltage at -30°C deviated from our design specification and simulation value because the offset voltages were found to vary randomly as a function of temperature.
만성 견비통에 대한 동씨침 치료의 무작위 대조군의 임상 연구
김찬영,권나현,신예지,남동우,김건형,김종인,최도영,이윤호,이재동 WHO COLLABORATING CENTRE FOR TRADITIONAL MEDICINE 2007 東西醫學硏究所 論文集 Vol.2007 No.-
Objectives : To observe the effect of acupuncture treatment in chronic shoulder pain patients. Methods : 36 voluntary patients were randomly assigned to an acupuncture treatment group(E GrouP, n=18) and a control group(C GrouP, n=18). The E Group patients received acupuncture treatment on LI_(15), TE_(14), GB_(21) and Master Dong's acupuncture points, Shin-gwan and Gyun-joong, twice a week for four weeks. The C Group patients received no treatment. All patients in both groups were instructed to practise self exercise in their daily lives. Evaluations were made at baseline and after four weeks of study. The Constant Shoulder Assessment(CSA), Shoulder Pain and Disability Index(SPADI) and the patient's subjective pain was measured by Visual Analogue Scale(VAS). The obtained data was analyzed. Results '. The E Group showed significant(p<0.05) improvement in CSA, SPADI and VAS after four weeks of treatment. The C Group showed significant(p<0.05) improvement in CSA, but the change of SPADI and VAS was insignificant(P>0.05). CSA and SPADI of E Group significantly(p<0.05) improved compared to the C GrouP, but the difference of VAS change in the two groups was insignificant(p>0.05). Conclusions : Four weeks of acupuncture treatment significantly improved CSA, SPADI and VAS. The improvement of CSA and SPADI was significant(p<0.05) compared to untreated patients.
오종진,김기대,이현동,김찬수,김성환,나건영 충남대학교 농업과학연구소 2002 농업과학연구 Vol.29 No.2
본 연구에서는 로타리 경운작업시 흙 부착이 가장 많이 되고 소요동력에 큰 영향을 미치는 로타리 커버 내측에 흙이 부착되는 것을 방지하여 경운 소요동력의 절감에 기여할 수 있는 로타리 커버를 개발하는데 목적이 있으며, 그 구체적인 연구결과는 다음과 같다. 1. 본 연구의 수행을 위하여 트랙터의 로타리 경운소요동력을 측정하고자 트랙터 PTO축과 로타리 동력 입력축을 연결하는 PTO 동력 전달축을 이용하여 로타리 경운 소요동력 측정장치를 설계, 제작하였다. 2. 로타리에 장착한 흙부착 방지장치의 재질로는 스테인리스 스틸, 고무, PE 등을 사용하였다. 흙부착 방지장치 장착 로타리를 이용하여 로타리 경운시험을 통한 경운 소요동력을 측정한 결과 평균 일반 로타리는 52.18ps, 스테인리스 스틸재질 장착 로타리는 52.44ps, 고무재질 장착 로타리는 49.01ps, 그리고 PE재질 장착 로타리는 46.34ps의 소요동력을 나타냈다. 3. 흙부착 방지장치 장착 로타리를 이용하여 로타리 경운시험 후 부착된 흙의 양을 조사한 결과 평균 일반 로타리는 5.6㎏, 스테인리스 스틸재질 장찰 로타리는 5.7㎏, 고무재질 장착 로타리는 3.1㎏, 그리고 PE재질 장착 로타리는 2.7㎏으로 나타났다. 4. 실험결과를 토대로 유의수준 5%의 모평균 차에 의한 검정으로 분석해본 결과 스테인리스 스틸재질의 경우 흙부착 방지효과가 없는 것으로 나타났으며, 고무와 PE재질의 경우에 방지 효과가 있는 것으로 나타났다. 그 중 PE 재질이 소요동력과 흙부착 방지에 각각 11%, 52%의 감소효과가 있어 소요동력 감소 및 흙부착 방지 효과가 탁월한 것으로 나타났다. This study aims at investigating the realities of tractor rotary tilling and paving operations performed by farm families in the central part of the country, measuring the power requirement so as to find the energy-saving factors for tractor rotary tilling, and designing a device to prevent soil adherence to the inside of the rotary cover-this part is the most subject to soil adherence and affects the power requirement. As a result of rotary tilling tests using rotaries equipped with a soil adherence preventer, the power requirement values were measured to be 52.18, 52.44, 49.01 and 46.34 PS for general, stainless steel, rubber and PE rotaries, and as a results of measurement of the quantities of the sod adhered to rotaries after their tilling tests, on the average, the quantities were measured to be 5.6, 5.7, 3.1 and 2.7㎏ for general, stainless steel, rubber and PE rotaries, respectively. The PE rotary cover reduced the power requirement and soil adherence by 11 and 52%, respectively.
SALS Study on Transcrystallization and Fiber Orientation in Glass Fiber/Polypropylene Composites
Na, Kun,Park, Han-Soo,Won, Hong-Youn,Lee, Jong-Kwan,Lee, Kwang-Hee,Nam, Joo-Young,Jin, Byung-Suk The Polymer Society of Korea 2006 Macromolecular Research Vol.14 No.5
This report presents a new technical approach for evaluating the fiber orientation of composites using small-angle light scattering (SALS). Glass fiber (GF)/polypropylene (PP) composites with different fiber orientations were prepared by drawing compression-molded specimens. The drawn samples were remelted and then annealed at $150^{\circ}C$ in order to induce a crystalline structure on the fiber surface, and then underwent SALS analysis. The samples showed a combination of circular and streak patterns. The model calculations demonstrated that the number of nuclei on the fiber surface and the thickness of the transcrystalline layer affected the sharpness and intensity of the streak pattern. In addition, the azimuthal angle of the streak pattern was found to be dependent on the direction of the transcrystalline layer, which correlated with the fiber direction. This correlation suggests that the fiber orientation in the composites can be easily evaluated using SALS.