http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
진단결장내시경술과 내시경 폴립절제술 비교에 의한 대장용종의 간과율
송주한 외 중앙대학교 의과대학 의과학연구소 2008 中央醫大誌 Vol.33 No.1,2
Colonoscopy is an effective method for discovery of adenomas and for colon cancer screening and prevention. However, it has been difficult to assess its accuracy. We retrospectively estimated the colonoscopic miss-rate of colorectal polyp and adenoma. We studied the data from patients who had colonoscopic polypectomy within 60 days after the initial examination. From 78 patients, a total of 235 polyps were found, 37 (15.7%) of polyps and 27 (14.2%) of adenomas were missed. As the size of polyps and adenomas decreased, the miss-rate increased significantly. Pathologic findings of missed polyps revealed adenoma (73.0%), hyperplasia (24.3%), inflammation (2.7%). Adenomas with high grade dysplasia were detected in 10.8% of missed polyps. The most frequent location was cecum and transverse colon. There was no difference of missing rate according to the shape of polyp, colonopist and number of polyps detected on the initial examination. There is a significant colonoscopic missing rate for colorectal polyps in routine clinical practice, especially in patients with small colorectal polyps and at the site of the cecum and transverse colon.
김주호,송지훈,신보철,한상오,송근호,이광래 江原大學校 産業技術硏究所 2001 産業技術硏究 Vol.21 No.B
Generally PbTiO3 if manufactured in a form of thin films which is useful for the application infrared sensors and non-volatile memory devices. Moreover PbTiO3 has a characteristic of adsorption for organic acid as well as electronic property. Organic acid adsorption properties of PbTiO3 powder prepared by sol-gel method was compared with the powder purchased from Aldrich Co. Crystallization and particle size of PbTiO3 are influenced by process variable, such as dilution of sol solution, catalysis, calcination temperature, calcination time, etc. As the size of PbTiO3 power decreased until several nanometers, adsorption of acetic acid and formic acid was increased 1.5-fold and 1.2-fold respectively
최정민,이송주,김부경,최영식,박요한,김정훈,허방 고신대학교 의과대학 2009 고신대학교 의과대학 학술지 Vol.24 No.1
The diffuse sclerosing variant (DSV) is a rare malignant tumour that accounts for 0.7-5.3% of all papillary thyroid cancers. DSV tends to occur at a younger age and has a higher incidence of cervical lymph node metastases, compared with papillary thyroid carcinoma. A 62-year-old female patient diagnosed thyroid nodule with diffuse and mild increased 18F-deoxy-glucose (FDG) on FDG positron emission tomography (PET)-computed tomogram (CT) scan. The ultrasound images showed typical findings of DSV such as diffusely enlarged thyroid lobes and diffusely scattered microcalcification. We performed this patient ultrasonography guided fine needle aspiration and cytologic analysis revealed papillary carcinoma. Total thyroidectomy with central compartment node dissection and lateral lymph node dissection was performed and finally diagnosed DVS. The authors report this case with literature review.
회분식 반응기에서의 공정변수 변화에 의한 침강성 탄산칼슘 제조
신보철,한상오,김주호,송지훈,송근호,이광래 江原大學校 産業技術硏究所 2001 産業技術硏究 Vol.21 No.B
For the preparation of calcium carbonate particles from aqueous Ca(OH)2 slurry, carbonation reaction of aqueous Ca(OH)2 slurry was carried out by batch method the CO2 into reactor filled with aqueous slurry of Ca(OH)2. The concentration of Ca(OH)2 varies from 1.00 to 7.00wt%, reactor temperature at 20 and 40℃, and reactor pressure from atmospheric pressure to 6.0kgf/cm2. Crystal structure of calcium carbonate was of calcite, the particle size were about 0.05 ∼2.0㎛, and the particle shape was cubic and spindle. When reactor temperature was higher, particle size of calcium carbonate was bigger and particle share was varied, but reaction rate was increased. When reactor pressure was higher, particle size of calcium carbonate was smaller, particle shape was cubic, and reaction ramie was increased.
신보철,한상오,김주호,송지훈,송근호,이광래 강원대학교 석재복합신소재제품연구센터 2001 석재연 논문집 Vol.6 No.-
본 연구는 탄산가스화법에 의한 탄산칼슘 입자 제조 공정에 있어서, 탄산가스로 채워진 반응기에 수산화칼슘 슬러리를 분사하는 방법으로 탄산칼슘 입자를 제조하였다. 수산화 칼슘의 농도(0.25~1.0wt%), 분사압력(0.5kgf /㎠~1.5kgf /㎠) 및 반응기 온도(20℃, 28℃)의 변화에 따른 생성된 탄산칼슘을 관찰하였다. 수산화 칼슘의 농도가 비교적 높으면(0.75wt%, 1.0wt%), 생성물의 pH와 전도도는 높게 나타났다. 분사압력에 의한 탄산칼슘 제조의 변화는 분사압력이 높아질수록(1.5kgf /㎠), pH와 전도도는 높게 측정되었다. 그러나, 수산화 칼슘의 농도와 분사압력의 변화가 탄산칼슘의 입자크기, 형태, 결정구조에 영향을 미치지는 않았다. 반응기의 온도가 28℃에서 생성된 탄산칼슘은 1.0㎛이하의 칼사이트 상 입자가 제조되었으며, 20℃에서 생성된 탄산칼슘은 0.5㎛이하의 칼사이트 상 입자가 제조되었다. 반응기의 온도가 낮아질수록 탄산칼슘 입자의 크기가 작아짐을 알 수 있었다. For the preparation of calcium carbonate particles from aqueous Ca(OH)2 slurry, carbonation reaction of aqueous Ca(OH)2 slurry was carried out by spouting the aqueous slurry of Ca(OH)2 into reactor filled with CO2 gas. The concentration of Ca(OH)2 varies from 0.25wt% to 1.0wt%, nozzle pressure from 0.5kgf /㎠ to 1.5kgf /㎠, and reactor temperature were set at 20℃ and 28℃. With relatively high concentration of 0.75wt% and 1.0wt% of Ca(OH)2, pH and conductivity of product-stream were observed high value. High pH and conductivity were observed at high nozzle pressure of 1.5kgf /㎠. The concentration of Ca(OH)2 and nozzle pressure, however, did not change the particle size and shape of calcium carbonate synthesized by carbonation reaction. The reaction temperature affected particle size. At reactor temperatures of 28℃ and 20℃, the particle sizes were about 1.0㎛ and 0.5㎛, respectively. Crystal structure of calcium calcium carbonate was of calcite. When reactor temperature was lower, the size of calcium carbonate particle was smaller.
조수헌,하미나,한상환,주영수,성주헌,강종원,윤덕로,송동빈,이명학,김선태 大韓産業醫學會 1996 대한직업환경의학회지 Vol.8 No.2
To determine the recovery time from noise-induced temporary threshold shift(TTS), a prospective field study was conducted at three worksites where workers are known to be exposed high level of noise. Subjects were selected according to answers on a questionnaire which inquired about otological history and previous noise exposure, including avocational, military and occupational exposures. After excluding employee with past otologic problems, recent exposure to high level noise, and under medications, total 92 employees participated in the study. Among 92 participants, complete consecutive audiometric examinations were carried out at 0∼2 hours, 5∼7 hours, 14∼16 hours after worktime noise exposure on 26 participants wearing hearing protectors and 22 participants wearing no protective devices. The difference between the hearing level 0∼2 hours after noise exposure and 5∼7 hours is statistically significant by paired t-test(p<0.01). The median recovery times calculated from the data of 22 participants wearing no protective hearing devices are 15.6 hours at 4000Hz, and 7.7 hours, 10.3 hours, 8.4 hours at 1000Hz, 2000Hz and 8000Hz respectively. These data suggest that when measuring the pure tone audiometry for noise exposed workers, at least 16 hours noise-free interval is required.
이근무,정승환,이정한,정순호,최영균,김영재,신치만,박주열,이영민 白中央醫療院 2005 仁濟醫學 Vol.26 No.1
Malignant hyperthermia is the disorder of calcium regulation within skeletal muscle associated predominantly with anesthesia. It is triggered by volatile anesthetics and depolarizing neuromuscular blocking agents. We experienced a case of malignant hyperthermia. 50 years old female patient was transferred to our emergency room that she was developed tachyarrhythmia and high fever. She was taken arthroscopic examination under the general anesthesia with enflurane and succinylcholine. We suspected malignant hyperthermia and promptly treated her with dantrolene sodium. She was developed disseminated intravascular coagulopathy and acute renal failure then we were intensive care to her. She was discharged without sequela. We experienced successful management of malignant hyperthermia.
Photonic microphone based on a dual-core multimode fiber head combined with a micromirror diaphragm
Song, Ju-Han,Lee, Sang-Shin Wiley Subscription Services, Inc., A Wiley Company 2007 MICROWAVE AND OPTICAL TECHNOLOGY LETTERS Vol.49 No.1
<P>A compact photonic microphone has been proposed and realized, incorporating a dual-core multimode fiber (MMF) block combined with a reflective micromirror-based diaphragm. The fiber block, where two MMFs are aligned and tilted toward each other with an angle, played a role as an optical head used to transfer light to and from the diaphragm. And the membrane-type micromirror made of a silicon film coated with gold films was implemented to be suspended via a thin bar connected to a silicon frame, thereby enabling dynamic displacement induced by applied acoustic waves. For the demonstrated microphone, its static characteristics were first examined to find out the operating point defined as the optimum distance between the optical head and the diaphragm. Its measured frequency response was examined to exhibit an operation bandwidth of 3 kHz with the variation of ∼5 dB. © 2006 Wiley Periodicals, Inc. Microwave Opt Technol Lett 49: 135–137, 2007; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.22088</P>